Marco OCEANIC 8.4kW User manual

Marco Beverage Systems Ltd.
INSTRUCTIONS FOR MODELS
OCEANIC 8.4kW
(P/N: 1000179D)
Water pressure :5 - 50 psi (min.-max.)35 - 345 kPa (min.-max.)
Marco Beverage Systems Limited.
63d Heather Road,
Sandyford Industrial Estate,
Dublin 18.
Marco Beverage Systems Limited.
Shire House, Strixton Manor,
Strixton, Wellingborough, Northants,
NN29 7PA
Ireland Tel: +353 (0)1 295 2674
Ireland Fax: +353 (0)1 295 3715
email: sales@marco.ie
www.marco.ie
UK Tel: +44 (0)2072 744 577
UK Fax: +44 (0)2079 788 141
email: sales@marco-bev.co.uk
www.marco-bev.co.uk

1900082 REV.1 Page 2 of 4
Installation details:
Power Supply:
Oceanic (8.4kW/400Vac. 3 PHASE) - This unit must be connected to a suitable 3 phase
power supply. This should be done bya qualified electrician.
Water Pressure: 5 - 50 psi (min.-max.) 35 - 345 kPa (min.-max.)
Installation procedure:
Fit a stop Valve ona cold water line and attacha 3/4" BSP male fitting,
(e.g. 3/4" x1/2" 311 or washing machine type stop valve).
Connect straight tailpiece of the hose to the stop valve fitting. Make sure that the pre-
attached sealing washer is fitted.
Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow
several gallons through.
Connect right-angled tailpiece of the hose to the inlet valve of the boiler (again 3/4" BSP).
Make sure the sealing washer is fitted here also.
Turnon water and check for leaks.
Connect to a suitable power supply.
Font Installation:
Counter Drilling:
Holes need to be drilled in the counter for the mounting bolts (6-10mm diameter). 4 holes are in
the base plate. Please use the dimensions shown below. A large hole needs to be drilled in the
counter (35mm diameter) for routing feed pipes and control wires.
Font Assembly:
Turn off the machine. The fonts are attached to the drilled counter with 4 x M6 nuts, bolts and
washers (all parts are found in the drip tray). A rubber grommet fits into the font base plate to
prevent the wire cutting against the steel edge. The silicone hose from the boiler is secured to the

1900082 REV.1 Page 3 of 4
black fitting from the font using the supplied hose clip. Connect the black wire coming from the
water boiler to the wires coming from the font base (it doesn’t matter which wire goes to which
connector onthe font)
Operating boiler for the first time:
Turn the water on at stop valve and switch the power onat the switch on the front of the machine.
1. Timer board works bydefault (after flashing) in "push& hold" mode.
2. To set a time dispense please follow the calibration procedure:
Open the service door on the front panel
Once the machine is full and heated up (the status LED glowing green) press the tactile switch
on the left control PCB (timer board).
Bothpumps will turn on and off for 0.1s - that will be heard as a click meaning that the timer is
inthe calibrationmode.
Place an empty cup (measuring jug) underneath the font that is to be calibrated.
Press and hold a font button until you get the right amount of water. The water does not have
to be dispensed in a single push - if the buttonis pressed few times the overall time will be
used.
Do the same action with the other font if needed. If onlyone font is calibrated, settings for the
other will not be altered.
The minimum time possible for the time dispense operation is 1s. Setting the dispense time for
less (quick font button click) will set the font back into "push & hold" mode.
After the volumes are set properly press the tactile buttonon the timer board once again.
Bothpumps will turn on and off for 0.1s twice - that will be heard as a double click meaning
that the timer is out of calibration.
3. Please note that there is no given order which font is to be calibrated first - in fact they
may be calibrated at once or only one may be calibrated (leaving the settings of the other
unaltered).
4. If there is no response from the user in the calibration mode (none of the font buttons
pressed) for more than 25 seconds the timer will end the calibration (double pump "click"
will be heard).
5. The maximum allowable time of the dispense is 25 seconds. Any longer times will be cut
down to 25 seconds.
6. The resolution of the time measurement is 0.1s.
7. The timer board has its own clock on board therefore power line frequency is not used to
measure the time.
Troubleshooting:
The Ready/Status light signals various errors or problems. A cycle of red flashes indicates an
error.
Status/Diagnostic light guide:
Status light
Symptom
Action required
2
Water level below elements -
Normal when machine first fills.
Check water supply , if this is OK
then call service agent.
3
Temperature sensor failure o/c
Call service agent
4
Water not heating
Call service agent
5
Temperature sensor failure s/c
Call service agent
6
Machine not filling
Check water supply , if OK then call
service agent.

1900082 REV.1 Page 4 of 4
Maintenance:
Marco machines have been designed to give many years of trouble free service. The only regular
maintenance required is occasional de-scaling.
Isolate machine from power supply.
Isolate machine from water supply.
ALLOW TO COOL COMPLETELY!
Remove the front panel and drain water from machine using the detachable silicon hose
running down the front side of the machine.
Remove lid.
Remove as much scale as possible by hand, paying particular attention to level probes
(White plastic withsteel tab). Be verycareful not to damage any attachments.
Use ScaleKleen, Marco part No. 8000270 or similar. Follow instructions carefully.
Thoroughly cleanand flush the machine before re-use.
Follow installation and first time operationinstructions
Cleaning:
The exterior of these machines may be cleaned with a damp cloth and a light detergent. Do not
use abrasive cloths or creams, as this will spoil the finish of the machine. Do not use a water jet
or spray. Beware of accidentally operating the draw off tap when cleaning the front of the
machine.
Limescale:
In common with all water boiler manufacturers, service calls resulting from limescale are not
covered by warranty. Fitting a scale reducer is recommended, especially in hard water areas.
This can reduce the build-up of scale but may not stop it altogether. The frequency that
descaling is required depends on the local water supply; hard water areas need more attention.
A scale reducer can reduce the build up of scaling, but may not stop it altogether. Descaling of
the machine should ideallybe carried out by qualified service personnel.
Cautions and safety tips:
This appliance must be earthed.
Risk of flooding. The hose supplied with this unit is non-toxic food quality tested to 190psi.
However, a hose is not a permanent connection. It is, therefore, advisable to switch off boiler
and close the stopcock valve when boiler is not in use, e.g. overnight, weekends etc.
Risk of scalding. Beware of accidentallypressing the font buttons while cleaning the fonts.
The utmost care has been taken in the manufacture and testing of this unit. Failure to install,
maintain and / or operate this boiler according to the manufacturer’s instructions may result in
conditions that can cause injury or damage to property. If in any doubt about the
serviceabilityof the boiler always contact the manufacturer or your ownsupplier for advice.
Table of contents
Other Marco Beverage Dispenser manuals
Popular Beverage Dispenser manuals by other brands

Cornelius
Cornelius R-404A REFRIGERANT Service manual

Cornelius
Cornelius ED 300 BC installation manual

U-Line
U-Line UCDE224BSS03A User guide & service manual

Cornelius
Cornelius Quantum 45200003 parts list

McDonald's
McDonald's CORNELIUS AUTOMATED BEVERAGE SYSTEM Operator's manual

Presto
Presto 02939 instructions