Hisar #1 str. v. Duvanlii 4174 region Plovdiv, Bulgaria
00359 887 27 33 47
sales@mareli-bg.com
www.mareli-bg.com
7
MARELI LTDMARELI LTDMARELI LTD
Hisar #1 str. v. Duvanlii 4174 region Plovdiv, Bulgaria
00359 887 27 33 47
sales@mareli-bg.com
www.mareli-bg.com
6
MARELI LTDMARELI LTDMARELI LTD
CAUTION!
Indoor Use Only – The equipment must be sheltered from exposure to the elements and extremes in temperature.
The sanitizer must not be exposed to moisture, condensation, water vapor or vibration.
The sanitizer should only be used and stored in dry rooms with a temperature range from 10° to 40°
Do not cover the unit.
No standing or sitting on the unit
Avoid exposure to direct or reected germicidal ultraviolet rays. Germicidal ultraviolet rays are harmful to the
eyes and skin. Use all protective equipment
Always use protective equipment when replacing the UV-C light source.
Do not change the design and construction of the unit.
Do not use the unit for any purpose other than those intended in this guide.
Do not remove any warning signs or stickers from the unit.
UV-C light sources should be cleaned every month carefully with a cotton cloth and alcohol.
The germicidal ultraviolet lamps used in the PurAIR® have a manufacturer’s rated average effective life of
9000 hours.Lamps may operate longer than their rated effective life, but the reduction in ultraviolet output
will make it impractical to use past the manufacturer’s rated life. For maximum efciency lamp replacement is
recommended every six months of continuous operation.
Repair of the unit or replacement of electrical parts must only be carried out by the manufacturer or a
authorized services.
WARNING!
Avoid exposure to direct or reected germicidal ultraviolet rays.
Germicidal ultraviolet rays are harmful to the eyes and skin.
To prevent the risk of severe or fatal electrical shock, special precautions must be taken since liquid is
present near electrical equipment.
• Always disconnect power before performing any service or maintenance.
Make sure the power plug is clean and insert it all the way into the socket.
• A dirty plug can cause a re or electrical shock.
The unit must not be modied or repaired by the customer. Contact with the manufacturer.
• If the power cord is damaged, it must be replaced by the manufacturer or authorized services to avoid haz-
ardous situations.
Do not insert ngers or any objects into the holes for inlet or outlet air.
• This may cause serious injuries.
In case you notice any unusual signs (in case of a burnt smell, for example), stop the unit and pull the plug of
the power cord from the socket or switch off the main power supply.
• Continued operation of the unit in the event of an abnormal condition may result in damage, re or electrical
shock. In such cases, contact the manufacturer or authorized services.
Do not wind, pull, damage, or modify the power cord.
Do not expose it to heating or place any objects on it.
• This may cause a re or electric shock.
UV-C light sources contain a small amount of mercury - beware of breakage! If you break a lamp, ventilate the
room where the breakage occurred.
Clean with a mercury vacuum cleaner or other suitable means that avoid the formation of dust and mercury va-
pors, such as a towel or syringe, which are also discarded after use, as well as personal protective equipment.
Hand over the hazardous waste to the local branch of the Ministry of Environment and Water with the help of a
closed container.
II. Warning / Caution III. How it’s work / Construction / Technical Characteristics
• Original PHILIPS® bactericidal ultraviolet lamps, which delivers ultraviolet energy with a specic wavelength of 254
nanometers (nm) and are highly effective against microbes in the air, including: virus, bacteria and mold spores.
• The device consists of a special UV powder coated outer housing and a stainless-steel inner housing in which the UV-C
tube is installed.
• With the help of two fans, air is forced into the disinfection chamber.
• The special construction prevents direct and indirect radiation of UV radiation.
• The device also has lters for capturing solid particles.
• Quick and easy access to replace the UV-C light source.
• Designed for use in hospital rooms, operating rooms, clinics, laboratories, pharmaceutical and food industries, ofces,
retail outlets, schools, kindergartens, homes.
How it’s work / Construction
Input Voltage, Frequency 220-240V / 50-60Hz
Electrical Power 95W (UV-C lamp with 2G11 socket)
Ingress protection IP20
Recommended room volume [m3/h] up to 120 m3/h
Noise emission [dB] 47 dB (+/- 5%)
Operating temperature [C°] 5° to 40°
Dimensions (mm)
Height: 1192
Width: 350
Depth: 107
UV-C tube
Brand: PHILIPS
Installed light 1
Consumption 95W
Wavelenght 254 nm
Tube replacement interval [h] 9000 hrs (75 % ±5 % output
performance)
Technical Characteristics
1192
443
350 107
187
A A
B B
C C
D D
E E
F F
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
LINEAR:
ANGULAR:
FINISH:
DEBURR AND
BREAK SHARP
EDGES
NAME
SIGNATURE
DATE
MATERIAL:
DO NOT SCALE DRAWING
REVISION
TITLE:
DWG NO.
SCALE:1:10
SHEET 1 OF 1
A4
WEIGHT:
Assem UVC_FACE