MARS COMMERCE GSW2 PLUS User manual

GSW2 PLUS
Advanced GSM/GPRS communication device
USER MANUAL

GSW2 PLUS
USER MANUAL
Page 1
Contents
1FOR YOUR SAFETY.............................................................................................................................................4
2INTRODUCTION...................................................................................................................................................5
3GSW2 PLUS ENTRY-CONTROLER FEATURES AND APPLICATIONS....................................................6
4START UP...............................................................................................................................................................7
5LED INDICATION.................................................................................................................................................8
6CONNECTION DIAGRAM ..................................................................................................................................9
7GSW2 PLUS UNIT MANAGEMENT ................................................................................................................11
8GSW2 PLUS FUNCTIONS WITH PROGRAMMING INSTRUCTIONS.....................................................12
8.1 WEB SERVER - LOG IN..................................................................................................................................................12
8.2 WEB SERVER –ADDING UNITS TO USER PROFILE................................................................................................13
8.3 WEB SERVER-UNIT MANAGEMENT ..........................................................................................................................15
8.4 WIEGAND ACCESS.........................................................................................................................................................16
8.5 CALLER ID ACCESS.......................................................................................................................................................19
8.6 OUTPUTS SETTINGS......................................................................................................................................................20
8.7 INTERCOM CONFIGURATION .....................................................................................................................................22
8.8 TIMER-TIMED CONTROLLED OUTPUT .....................................................................................................................24
8.9 ALARM INPUTS ..............................................................................................................................................................26
8.10 ADMINISTRATION.........................................................................................................................................................28
8.11 GSW2 PLUS WIEGAND OUTPUT INTEGRATION......................................................................................................30
8.12 EVENT LOGGING ...........................................................................................................................................................31
8.13 MISCELLANEOUS ..........................................................................................................................................................32
8.14 PIN ACCESS NOTIFICATION FUNCTION ...................................................................................................................33
9WIEGAND INPUT DATA FORMATS..............................................................................................................35
9.1 WIEGAND 26 BIT, DIFFERENT DATA FORMATS .....................................................................................................36
9.2 WIEGAND 30 BIT, DIFFERENT DATA FORMATS .....................................................................................................37
10 CONTACTS ..........................................................................................................................................................38

GSW2 PLUS
USER MANUAL
Page 2
Figures
Figure 1: GSW2 PLUS: Connection diagram......................................................................................9
Figure 2: GSW2 PLUS: Connection table.........................................................................................10
Figure 3: WEB Server-Sign In page..................................................................................................12
Figure 4: WEB Server-Main page select ADD mode........................................................................13
Figure 5: WEB Server-Main page adding GSW2 PLUS units..........................................................14
Figure 6: WEB Server-Unit management window............................................................................15
Figure 7: WEB Server-Wiegand interface support............................................................................16
Figure 8: WEB Server-Adding Wiegand devices with permanent use..............................................17
Figure 9: WEB Server-Adding Wiegand devices with temporary use..............................................17
Figure 10: WEB Server-Caller ID Access.........................................................................................19
Figure 11: WEB Server-Output setting..............................................................................................20
Figure 12: WEB Server-Intercom settings.........................................................................................22
Figure 13: WEB Server-Timer setting →Day mode. ........................................................................24
Figure 14: WEB Server-Timer setting →Week mode.......................................................................24
Figure 15: WEB Server-Input alarm mode........................................................................................26
Figure 16: WEB Server-Notification numbers ..................................................................................28
Figure 17: WEB Server-Input alarm configuration ...........................................................................28
Figure 18: WEB Server-Wiegand Output settings.............................................................................30
Figure 19: WEB Server-Log event ....................................................................................................31
Figure 20: WEB Server-Misc ............................................................................................................32
Figure 21: WEB Server-Global enabling of the notification function...............................................33
Figure 22: WEB Server-Selecting administrator numbers for notification. ......................................34
Figure 23: WEB Server-First Wiegand interface support..................................................................35
Figure 24: WEB Server-Second Wiegand interface support.............................................................35

GSW2 PLUS
USER MANUAL
Page 3
Tables
Table 1: WEB Server - SPIN entry parameters. ................................................................................18
Table 2: WEB Server-Timer setting, output mode options ...............................................................25
Table 3: Wiegand 26: Mode 0............................................................................................................36
Table 4: Wiegand 26: Mode 1............................................................................................................36
Table 5: Wiegand 26: Mode 2............................................................................................................36
Table 6: Wiegand 26: Mode 3............................................................................................................36
Table 7: Wiegand 30: Mode 0............................................................................................................37
Table 8: Wiegand 30: Mode 1............................................................................................................37
Table 9: Wiegand 30: Mode 2............................................................................................................37
Table 10: Wiegand 30: Mode 3..........................................................................................................37

GSW2 PLUS
USER MANUAL
Page 4
1FOR YOUR SAFETY
SWITCH ON SAFELY
Do not switch the unit on when use of wireless phone is prohibited or when it may cause
interference or danger.
INTERFERENCE
All wireless phones and units may be susceptible to interference, which could affect performance.
SWITCH OFF IN HOSPITALS
Follow any restrictions. Switch the unit off near medical equipment.
SWITCH OFF IN AIRCRAFT
Follow any restrictions. Wireless devices can cause interference in aircraft.
SWITCH OFF WHEN REFUELING
Do not use the unit at a refueling point. Do not use near fuel or chemicals.
SWITCH OFF NEAR BLASTING
Follow any restrictions. Do not use the unit where blasting is in progress.
USE SENSIBLY
Use only in the normal position as explained in the product documentation. Do not touch the
antenna unnecessarily.

GSW2 PLUS
USER MANUAL
Page 5
2INTRODUCTION
GSW2 PLUS is a simple but powerful GSM switch and communication system designed to ensure
low-cost, simple to install/use, reliable and single box solution for remote managed switching
application and secure intercom solution. It is designed for unlimited range, pin code access, caller
ID control and Wiegand access support.
Optional GSW2 PLUS supports alarm detection, stay-alive messages, credit detection etc…

GSW2 PLUS
USER MANUAL
Page 6
3GSW2 PLUS ENTRY-CONTROLER FEATURES AND
APPLICATIONS
Features:
Built-in 4 (2G) or 5 (3G) band GSM module
Caller ID numbers control (up-to 1000 caller ID numbers)
Up to 100 temporary SPIN access codes
Up to 1000 PIN access codes
Input Wiegand receiver
2 outputs (relay supported)
Secure intercom support (with external Audio module)
Programming with PC via “USB to Mini USB cable” connected to the unit
Programming by WEB server
Programming by SMS commands
Applications:
Secure intercom solution (with separate call module)
Remote gate opener –Caller ID number recognition
Simple (Wiegand) access system

GSW2 PLUS
USER MANUAL
Page 7
4START UP
GSW2 PLUS unit accepts a standard GSM SIM cards from any network.
VERY
IMPORTANT
USE A MICRO SIM CARD
WARNING
DO NOT Insert or remove the SIM card while the unit is powered ON!!
IMPORTANT
Before inserting SIM card to unit make sure the PIN code is
removed!!
Insert SIM card in GSW2 PLUS unit.
Connect power cable to GSW2 PLUS unit (YOU MUST POWER THE GSW2 PLUS UNIT
WITH THE POWER SUPPLY IF INCLUDED. Do not power with any other power
supply).
Power up the unit.
Wait until LED1 (blue) starts flashing. This is set in around 30 –45 seconds.
GSW2 PLUS unit is now ready to operate.

GSW2 PLUS
USER MANUAL
Page 8
5LED INDICATION
Blue LED (LED1)
-Indicates the level of the GSM signal from 1 to 5 LED flashes (1 is weak signal, 5 is
excellent signal)
Red LED (LED2)
-GSM module Activity
Yellow LED (LED3)
-Short flashing indicates that the GSM module is ON, but it is not yet connected on the GSM
network. After connection, yellow led is flashing with short pulse (0,5s) ON and a long
pulse OFF (5s).

GSW2 PLUS
USER MANUAL
Page 9
6CONNECTION DIAGRAM
Before connection the GSW2 PLUS please take a look at connection diagram.
Figure 1: GSW2 PLUS: Connection diagram

GSW2 PLUS
USER MANUAL
Page 10
PS
Power supply
BATT+
Back-up Battery connection
PS
BATT-
IN1
Alarm input 1 / Call button 1
G
GSM Intercom –Call point
connections
IN2
Alarm input 2 / Call button 1
B
1C
Relay output 1 –Common
W
1NC
Relay output 1 –Normal Close
Y
1NO
Relay output 1 –Normal Open
CB1
2C
Relay output 2 –Common
AUX
2NC
Relay output 2 –Normal Close
GND
2NO
Relay output 2 –Normal Open
WIEGAND
Wiegand input connector
AUX
+12V AUX max. 100 mA in total!
ANT
GSM Antenna
GND
Ground
USB
USB conn. for programming with PC
OUT 3
Wiegand output D0
OUT 4
Wiegand output D1
GND
Ground
A
RS485 A
B
RS485 B
TMP
Temperature probe connector
Figure 2: GSW2 PLUS: Connection table.
IMPORTANT
DO NOT USE Power out (12V AUX) for electric lock driving! Use
separatepowersourcefordoorelectric lock!

GSW2 PLUS
USER MANUAL
Page 11
7GSW2 PLUS UNIT MANAGEMENT
Unit supports different types of management (programming):
Unit can be programmed directly by USB connection, with the use of configuration software
running on PC (EasySet).
Unit can be programmed remotely by using WEB server access.
Unit can be programmed remotely by SMS commands (Optional).

GSW2 PLUS
USER MANUAL
Page 12
8GSW2 PLUS FUNCTIONS WITH PROGRAMMING
INSTRUCTIONS
As mentioned in previous chapters GSW2 PLUS unit can be programmed in various ways, this
document will focus on most common programming way: WEB programming.
IMPORTANT
SIM card in the GSW2 PLUS unit MUST have DATA PLAN to be able to
use WEB programming!
8.1 WEB SERVER - LOG IN
The web server can be find under the address: https://www.easyset.eu/.
Figure 3: WEB Server-Sign In page
User must first use the Sign IN section to create working profile on the server. The profile can be
created by using social login like Facebook, Google account or Twitter. The user lacks any of the
social profile it can proceed to Sign UP page use standard user name and password entry.
NOTE
Server supports Firefox, Google Chrome, Safari.

GSW2 PLUS
USER MANUAL
Page 13
8.2 WEB SERVER –ADDING UNITS TO USER PROFILE
After login the user will be diverted to WEB server main window. This page is used to
add/remove/search for GSW2 PLUS units from the user’s profile.
Select “+” sign to select ADD GSW2 PLUS units to user’s profile.
Figure 4: WEB Server-Main page select ADD mode

GSW2 PLUS
USER MANUAL
Page 14
Figure 5: WEB Server-Main page adding GSW2 PLUS units
User than provides required data:
Name: Name for the added unit - mandatory information.
IMEI: Identification number of the unit, can be found in the enclosure of the unit -
mandatory information. The IMEI is located on the cellular chip and also should be on the
card board box of the GSW2 PLUS.
Phone Number: The telephone number of the SIM card in the GSW2 PLUS unit -
mandatory data.
GPRS settings: Information needed to enable data connection between the server and the
unit. Selectable from the drop-down menu - mandatory data.
Location: Notification field, used by the user to provide extra data for its own information -
optional data.
By clicking the “+” (insert sign) after filling mandatory data, the unit will be added to the user
profile.
First building of the unit data-base may take a few minutes.

GSW2 PLUS
USER MANUAL
Page 15
8.3 WEB SERVER-UNIT MANAGEMENT
After the GSW2 PLUS unit is added to user database, the user can change the configuration of the
specific unit.
All changes made by the user are listed in the Change Log window. By clicking Send to device
button ALL changes are sending to the unit. User can revert all changes made, before sending, by
clicking Revert all or select particular entry and revert it.
Figure 6: WEB Server-Unit management window

GSW2 PLUS
USER MANUAL
Page 16
8.4 WIEGAND ACCESS
GSW2 PLUS unit has onboard support for 1 Wiegand output based device. With the user of
external replicator more Wiegand devices can be connected to the unit.
Configuration of Wiegand interface is found in Digital interface tab in the Input section. Wiegand
interface can be found on board with a dedicated Wiegand connector and cables.
Figure 7: WEB Server-Wiegand interface support.
Mode: Select appropriate data formatting (Advise unit provider for more info if needed,
mode 2 is most common setting)
Facility code: User can Enable or Disable facility code field.
Wiegand devices can be defined in two sections. First section is permanent pin codes and second is
temporary pin codes - limited by the number of use.
NOTE
See Chapter 9-WIEGAND INPUT DATA FORMATs for detailed explanation
of different data format options.

GSW2 PLUS
USER MANUAL
Page 17
Permanent use: devices are added in Pin access tables.
They are placed in two tables. For each table user can define which output they will trigger.
Figure 8: WEB Server-Adding Wiegand devices with permanent use.
PIN entry: For each PIN entry user need to select PIN code value and optional User name.
Temporary pin codes are placed in Temporary pin access tab.
Figure 9: WEB Server-Adding Wiegand devices with temporary use.
Temp PIN codes activate output: Selecting the output that will be triggered in case of
correct SPIN code.

GSW2 PLUS
USER MANUAL
Page 18
SPIN entry: For each SPIN entry user need to select appropriate values.
SPIN options
Desription
SPIN value
Temporary PIN code
User name
Name of the user
Notify
If SPIN code is used, administrator numbers CAN be notified
Counter limit
Enable/Disable counter limitation (consecutive use)
Timer limit
Enable/Disable timer limitation
Timer mode
Timer limit mode: Day limit (day limitation), Timer limit
(hours of a day access limitation)
Rules valid on weekend
Enable/Disable timer limitation for weekend days
Counter
Number of allowed use of SPIN code
Timer start/Timer end
Bottom and Top timer limitation
Table 1: WEB Server - SPIN entry parameters.

GSW2 PLUS
USER MANUAL
Page 19
8.5 CALLER ID ACCESS
Caller ID access is a very simple way to control relay output defined in Caller ID output setting.
User will by calling in the GSW2 PLUS unit trigger defined output.
Settings for this function are found in the Caller id # tab.
Figure 10: WEB Server-Caller ID Access
General settings:
Caller ID security mode: User can select between 3 options:
Caller ID Disabled deactivates caller ID function –all numbers are restricted
Caller ID for specific users will limit the caller ID function only to the numbers on the list.
Caller ID always ON will allow all users that know the number of the unit to open defined
output. In last option the user doesn’t need to be on the list to trigger the output
Caller ID output: Selecting the output that will be triggered in Caller ID function.
NOTE
Selection Caller ID always ON will allow anybody with the knowledge of the
unit number to trigger the output by calling the unit. Use this setting with
caution.
Other manuals for GSW2 PLUS
2
Table of contents
Other MARS COMMERCE Conference System manuals
Popular Conference System manuals by other brands

TANDBERG
TANDBERG Edge MXP Series Installation

Biamp
Biamp Devio SCX 400 Installation & operation guide

Highfive
Highfive RB1 quick start guide

Gehrke
Gehrke NeuroKom IP DS 935-SH product manual

INIM Electronics
INIM Electronics SmartLink-P Installation and programming manual

AT&T
AT&T Merlin Legend BIS22D quick reference