MARS COMMERCE GSW2 PLUS User manual

GSW2 PLUS 1000 NEW
QUICK START GUIDE
Please use web server on: www.easyset.eu
1. BEFORE INSTALLATION, READ THIS QUICK START GUIDE FIRST!
2. Install wiring from power source to GSW2 PLUS location.
3. IMPORTANT: USE A MICRO SIM CARD (Micro-SIM) WITH MEMORY FOR
UP TO 250 CONTACTS! Insert SIM card to be used for GSW2 PLUS in
your personal mobile phone to erase PIN code.
4. IMPORTANT: ERASE THE PIN CODE ON SIM CARD!
5. Insert SIM card in GSW2 PLUS device as detailed below –gold contacts
down and cut off corner RHS. The unit must be switched OFF when you
insert the SIM! Insert SIM carefully as SIM holder is fragile if forced!
6. Connect outputs to GSW2 PLUS device.
7. Connect power cable to GSW2 PLUS device.
8. Connect device to source power supply voltage (12-20VAC or 12-24VDC).
9. Wait until YELLOW LED start flashing in 5 sec interval (0,5 sec ON / 5 sec
OFF) and BLUE LED starts flashing. This is set in around 30 seconds.
10. GSW2 PLUS device is now ready to operate.
WIRING
Wiring is minimal and apart from power supply source to GSW2 PLUS & door
release (gate automatic etc.) wires, there is no other required wiring.
POWER
SUPPLY
Power supply –12 to 20 V AC
or 12 to 24 V DC
OUT3
Wiegand output DOUT 1
OUT4
Wiegand output DOUT 0
IN1
Alarm input 1
GND
Ground
IN2
Alarm input 2
A
RS485 A
1C
Relay Output 1 –Common
B
RS485 B
1NC
Relay Out. 1 –Normal Close
TMP
Temp. connector - optional
1NO
Relay Out. 1 –Normal Open
SIM
Micro SIM card holder
2C
Relay Output 2 –Common
USB
USB for prog. with PC
2NC
Relay Out. 2 –Normal Close
ANT
GSM Antenna
2NO
Relay Out. 2 –Normal Open
Wiegand
input
GND
Ground
AUX
+12V DC AUX - *100 mA
max.
CB1
Call Button 1 –same as IN1!
Y W
B G
GSM Intercom –Call point
connections
BATT-
Backup Battery –(minus)
2G or 3G
2G or 3G version
BATT+
Backup Battery + (plus)
XT
Extended version
*Do not use the 12V AUX power output for electric lock driving! You can
use it to powerexternal sensors: Short-term current load (up to 1 minute)
- up to 500mA; Long-term currentload - up to 100mA! Use separate
power source for door electric lock!
SIM CARD (Micro SIM)
Insert the SIM card gold contacts down with the cut off to the RHS as
shown above. Insert SIM carefully. It will NOT break unless forced!
SET AUTHORISED CALLER ID USERS (1000 user version)
;CLP1=07796176545;CLP2=xxxxxxxxxx;CLP3=xxxxxxxxxx;CLP4=
xxxxxxxxxx;CLP5=xxxxxxxxxx;CLP6= xxxxxxxxxx;CLP7………(up to 1000);
SET ‘ANY CALLER’ MODE FOR CALLER ID ACCESS
Any number can switch the door release by calling the GSW2 PLUS ;CLPEN=2;
SET ONLY ‘
AUTHORISED CALLER ID USERS
’ HAVE CALLER ID ACCESS
Only Caller ID users can switch the door release by calling the unit ;CLPEN=1;
REQUEST CURRENT CALLER ID USERS (and other settings)
Request ALL 200 users in multiple messages: ;PCLP;
Request a select range (use any range): ;PCLP=1,5;
SETUP ACCESS CODES (PIN1 to PIN1000) –(3rd party Wiegand):
NOTE: PIN1 to PIN500 for Relay 1, PIN 501 to PIN1000 for Relay 2.
Set PIN access codes by sending SMS to GSW2 PLUS:
;PIN1=1234;PIN2=2345;…;PIN1000=5588; (first digit ≥ 1)
Delete PIN access codes by sending: ;PIN1=; … up to ;PIN1000=;
Check current PIN access codes: Request all PIN codes: ;PPIN;
Request a block of PIN codes: ;PPIN=1,5; (access codes 1 –5)
SETUP TEMPORARY SPIN ACCESS CODES (SPIN1 to SPIN100):
Up to 100 SPIN Access Codes and how many of times will it be used.
NOTE: Set the SPIN codes active output first: ;SPINO=1;. and SPIN code and
how many times will it be used: ;SPIN8=4321;SPINC8=3;
Explanation: Output set to trigger is Relay 1, SPIN8 code 4321 can be used 3
times and after the 3th time won’t be valid anymore.
Check current SPIN access codes: ;PSPIN; - prints SPIN parameters.
SET UP DOOR RELEASE SWITCHING MODE
Default is 3 sec pulse (suits automatic gates)
Change to 30 second pulse: ;OS1=30;
Change to latching (on/off): ;OS2=1; (relay 2 hold open function)
SET AS ‘1ST CALL OPEN’ / ‘2ND CALL CLOSE’
The output can be set to switch on with the first call from an authorized
number & off with the next. This works when you set the relay output by SMS
as follows: ;OS1R=1; (for 1st relay) or ;OS2R=1; (for 2nd relay).
ACCESSING TO THE UNIT FOR CHANGING PARAMETERS:
Set the TN1 –TN5 telephone numbers of Authorized Users, who have the
full access to the GSW2 PLUS unit (to set or delete Caller ID numbers of the
users, change parameters, receive alarms, …):
;TN1=xxxxxxxxxx;TN2=xxxxxxxxxx;…;TN5=xxxxxxxxxx;
SECURITY LEVEL –SL:
SL parameter from 0 to 5 defines which telephone number stored in the
phone book from TN1 –TN5 can enter into programming and remote
control of the GSW2 PLUS.
SL=0 –All calls and SMS are accepted to the GSW2 PLUS unit,
SL=1 –Only number stored under parameter TN1 has access to the unit, …
SL=4 –Numbers stored under parameters TN1 to TN4 have access to unit.
Example: ;SL=1; –Only the TN1 has access to the GSW2 PLUS unit.
OPERATION & TESTING
Follow these steps to test the system…
1. SWITCH ON POWER: The device starts to initialize indicated by
YELLOW flashing once per second. When YELLOW is flashing once
per 5 second it is registered to the network and BLUE flashes signal
strength, the device is ready to program. Between 2 –5 BLUE
flashes is recommended.
2. PROGRAM BY SMS: Send minimum setting (1 User phone
number): ;CLP1=xxxxxxxxxxxx; (using your own phone number)
3. ENTRY CONFIRMATION: Check entry by sending: ;PCLP=1,2; and
the device will send the first two entered phone numbers. If you do
not receive a reply, the device is not yet registered to the GSM
network or there is no credit on the SIM card!
4. CALL THE GSW2 PLUS DEVICE: Call from the phone number set as
CLP1 to test the output switch.
PROGRAMMING SOFTWARE EASYSET
Test the unit before trying to use programming software.
NOTE: If you are using 1 alarm input and 1 or a few users, it is far
more efficient to use the above SMS set up procedure.
1. Get the software EasySet & USB driver files from the CD or WEB.
2. Install the EasySet software (please be carefull to download the
correct PC program - x86 or x64): Double click on *.msi file.
3. Plug device into your PC with USB to Mini USB cable:With valid
SIM card and in normal operation mode –the GSW2 PLUS device
must be registered on the GSM network (BLUE LED: 2 –5 flashes.
4. Start EasySet SW: Double click on EasySet icon. The GSW2 PLUS
must be connected to PC via USB. Select connection port: choose
the COM port number (Device manager →Ports) and click
Connect.
5. Program settings: Always “Read configuration” first, before any
programming action by PC. Go through the tabs to change settings.
From the ‘Home’ tab press “Send configuration” to program the
GSW2 PLUS. Then “Save configuration to file” for future access via
“Load configuration from file”.
TROUBLESHOOTING
Please check the following before calling for support.
1. You have GSM signal (BLUE flashing LED),
2. You have a tested, credited, working SIM,
3. You have followed above ‘OPERATION & TESTING’ procedure.
TECHNICAL SUPPORT
See the complete Installation Manual for full information. This is a basic
“Quick Start Guide” only. Please contact your Supplier for further
information, if you have tried the above and cannot resolve the issue.

Web Server: www.easyset.eu
Our Android apps EasySet you can install free of charge from Google Play:
https://play.google.com/store/apps/details?id=com.marscommerce.esweb
https://play.google.com/store/apps/details?id=com.marscommerce.easycontrol
Our IOS apps EISWARE you can install free of charge from Apple Store:
https://itunes.apple.com/app/eisware-web/id1137960053?mt=8
https://itunes.apple.com/us/app/eisware-control/id1220908841?mt=8
Other manuals for GSW2 PLUS
2
Other MARS COMMERCE Conference System manuals
Popular Conference System manuals by other brands

Prentke Romich Company
Prentke Romich Company Vanguard Plus Operator's manual

Cisco
Cisco Telepresence MX200 quick start guide

Veris Industries
Veris Industries H8163-CB installation guide

Aethra
Aethra vega X5 user manual

Polycom
Polycom ReadiManager LX 100 Getting started guide

Takstar
Takstar WTG-700 user manual