Martin 05 User manual

05 Repeater
user manual

Measurements are in millimeters
43
172 98
203
Product
Alien O5 Repeaterbox
Description
Dimensions
Weight (kg)
Scale Date Sign
06.11.2002 NPE
0.5
60
Ø8
188
Ø4.5
© 2002 Martin Professional A/S, Denmark.
All rights reserved. No part of this manual may be reproduced, in any form or by any means, with-
out permission in writing from Martin Professional A/S, Denmark.
Printed in Denmark.
P/N 35000123, Rev A

3
INTRODUCTION
Thank you for selecting the Martin 05 Repeater. The 05 Repeater is part of
the Alien 05 system and is used to connect up to 24 additional Alien 05
luminaires to a single control channel from the 05 Driver unit. These
luminaires will respond in the same way as they will have the same control
signal.
For a detailed description of the Alien 05 System, refer to the 05 Driver user
manual.
SAFETY INFORMATION
Warning! This product is not for household use.
Read this manual before powering or installing the device, follow the safety
precautions listed below and observe all warnings in this manual and on the
housing. If you have questions about how to operate the system safely,
contact your Martin dealer or call the Martin 24-hour service hotline at +45
70 200 201.
• Install only in a dry area.
• Refer electrical installation to a qualified electrician.
• Refer all service to a Martin technician.
• Use only a source of AC power that complies with local building and
electrical codes and has both overload and ground-fault protection.
• Do not remove the cover.
• Do not modify the device.
POWERING THE 05 REPEATER
The 05 Repeater features an auto-ranging power supply. It is suitable for
use with 90 - 250 V, 50/60 Hz mains supplies. Use a cable with a 3 pin IEC
female plug.
Warning! For protection from dangerous electric shock, the fixture must
be grounded (earthed). The AC mains supply shall be fitted with
a fuse or circuit breaker, ground-fault protection, and a means
to isolate the fixture from the mains during service or when not
in use. Refer electrical installation to a qualified electrician.

4
CONFIGURATION
Channel signal input
The channel signal input connector is labeled Alien driver Channel link
Out/In (the two connectors are interchangeable, so use either one of them).
Use a CAT5 cable to connect this to:
• One of the six output channels on an 05 Driver, or
• One of the six output channels on another 05 Repeater (that is itself
connected directly or indirectly to an 05 Driver), or
Driver
Repeater
Repeater
Repeater

5
•TheAlien Driver Channel link Out on another 05 Repeater (that is itself
connected directly or indirectly to an 05 Driver that is not more than 40
metres of cable length away).
Connecting Alien 05 luminaries to the 05 Repeater
You can connect up to twenty-four Alien 05s to a single 05 Repeater - in 6
outputs (A-F), each containing up to four daisy-chained luminaries.
The maximum data cable length between the 05 Repeater output and the
last fixture in the daisy chain is 40 meters (130 feet).
Connecting additional 05 Repeaters
Up to eight 05 Repeaters can be daisy-chained using the Alien Driver
Channel link Out/In connectors, but note that this connector is unamplified
and that the last fixture in this daisy chain should not be more than 40 cable
meters (130 feet) away from the 05 Driver.
You can also connect a single 05 Repeater to each or any one of the 6
amplified Output (A-F) connectors on an 05 Repeater, and then connect
additional s05 Repeater to those. In this way a theoretically unlimited
number of 05 Repeaters may be connected to an single O5 Driver.
Warning: Do not mix Alien 05 luminaries and 05 Repeaters on the same
Output link. Connect only Alien 05 luminaires, or only a 05
Repeater, to an individual connector. This applies to both the 05
Driver and the 05 Repeater.
Driver
Repeater

6
FIXTURE LOCATION
Once the Alien system is set-up and running, there should be no need to
access the 05 Repeater. It may be installed in any convenient location that
meets the following conditions:
• The maximum tested data cable length between the 05 Repeater and any
directly connected Alien 05 luminaire is 40 meters (130 feet).
• The maximum tested data cable length between an 05 Repeater and an
amplified signal source (05 Driver outputs 1-6 or O5 Repeater outputs A-F)
is 40 meters (130 feet).
• The maximum tested total data cable length between an 05 Repeater and
an unamplified signal source (an 05 Driver via Alien driver Channel link
In/Out connectors on 05 Repeaters) is 40 meters (130 feet).
• The ambient temperature does not exceed 40° C (104° F).
• The unit is protected from moisture.
Four 7 mm (1/3 in.) holes are provided on the 05 Repeater casing for fixed
installation.
OUTPUT FAILURE LEDS
When illuminated, these LEDs - for outputs A to F - indicate that there has
been a line failure on the associated Output connector. Power off the 05
Repeater, check that all the cables are connected properly, and power it on
again.
If the problem persists, or if more than one of the Output Failre LEDs light
simulataneously, then this may be due to:
• Too high a load on the line. Ensure that the distances between the fixtures
do not exceed the recommended maximums and that there are not too
many fixtures on the network.
• Failure of the Alien driver Channel link In/Out connector. There may be a
failure with the connector or a cable connected to it. Disconnect power to
the system and check all the connections and cables before applying power
again.
If problems persist consult your Martin dealer for support.

Specifications - 05 Repeater
7
S
PECIFICATIONS
- 05 R
EPEATER
Physical
Size (L X W x H). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203 x 98 x 43 mm (8 x 3.9 x 1.7 in.)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.55 kg (1.2 lbs.)
Control
Remote interfaces: . . . . . . . . . . . . . . . . . . . . .DMX-512, Martin Oracle both via an 05 Driver
Data input: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CAT5 network cable (not supplied)
Data output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CAT5 network cable (not supplied)
Thermal
Maximum ambient temperature (Ta): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40° C (104° F)
AC Supply
Power supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Auto-ranging - 90 - 250 V, 50/60 Hz
Construction
Housing: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . sheet aluminum
Finish: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . electrostatic powder coating
Color:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . black (RAL 9005)
Accessories
Alien 05 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90340000
Oracle: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90722000
05 Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90722010
CAT5 network cables - 2 m (6.5 ft) x 50 pieces:. . . . . . . . . . . . . . . . . . . . . . . . . P/N 91611044
CAT5 network cables - 5 m (16.4 ft) x 30 pieces:. . . . . . . . . . . . . . . . . . . . . . . . P/N 91611045
CAT5 network cables - 10 m (32.8 ft) x 15 pieces:. . . . . . . . . . . . . . . . . . . . . . . P/N 91611045
Table of contents
Popular Repeater manuals by other brands

Lenze
Lenze CAN EMF2176IB Mounting instructions

Nikrans
Nikrans BD-18K-Voice 3G PRO quick start guide

NetComm
NetComm Velocity NP124 Setup guide

Kindermann
Kindermann 4K60 Audio Extraktor Mounting and operating instructions

DMP Electronics
DMP Electronics 1100R installation guide

Ntron
Ntron SER-485-IR quick start guide