5GPac Installation Instructions 11/07-2
Chapter 3 Model ID & Serial Number Explanation
Chapter 4 Safe Installation Requirements
WARNING
FIRE, EXPLOSION AND ASPHYXIATION HAZARD
Improper adjustment, alteration, service, maintenance or installation could cause serious
injury, death and/or property damage.
Installation or repairs made by unqualied persons could result in hazards to you and
others. Installation MUST conform with local codes or, in the absence of local codes, with
codes of all governmental authorities have jurisdiction.
The information contained in this manual is intended for use by a qualied service agency
that is experienced in such work, is familiar with all precautions and safety procedures
required in such work, and is equipped with the proper tools and test instruments.
AVERTISSEMENT
DANGER D'INCENDIE, EXPLOSION OU ASPHYXIE
Une mauvaise exécution d'installation, réglage, altération, intervention ou entretien peut
causer dégâts matériels et dommages corporels ou même mort.
Une installation ou des réparations faites par des personnes non qualiées peuvent
entraîner des dangers pour vous et les autres. L'installation DOIT être faite en conformité
avec les normes locales, ou en leur absence avec les normes des autorités nationales
ayant juridiction en la matière.
Les informations contenues dans ce manuel sont prévues pour être utilisées par une
agence de dépannage qualiée, ayant de l'expérience dans ce type de travaux, familière
avec les précautions et procédures de sécurité que cela implique, et équipée des outils et
instruments de test adéquats.
NOTE: This furnace is design-certied by the CSA International (formerly AGA and CGA) for installation in
the United States and Canada. Refer to the appropriate codes, along with this manual, for proper installation.
Air Source
Vertical
Gas
Nominal Cooling
24 = 24,000 BTUH
30 = 30,000 BTUH
36 = 36,000 BTUH
42 = 41,500 BTUH
48 = 48,000 BTUH
60 = 55,000 BTUH
System Type
Air Conditioner
Power Supply
A = 208/230V, 1ø, 60Hz
C = 208/230V, 3ø, 60Hz
D = 460V, 3ø, 60Hz
Ventilation Configuration
N = 0-15% fresh air with manual damper, no pressure relief.
Y = 0 to 450 cfm of outside air, field adjustable, manual damper, no
pressure relief.
Z = 0 to 450 cfm of outside air, field adjustable, manual damper,
includes pressure relief.
B = Motorized two position damper (open & closed) capable of 0 to
450 cfm of outside air, includes pressure relief.
C = Economizer; capable of 100% of rated cooling capacity using
outside air.
H = GreenWheel®energy recovery ventilator
Heating Input (MBTUH)
045 = 45,000 BTUH
067 = 67,000 BTUH
090 - 90,000 BTUH
075 = 75,000 BTUH
100 = 100,000 BTUH
125 = 125,000 BTUH
Model Identication
AVG • AC • •• •
Serial Number Date Code
A = January E = May J = September L = 2000 R = 2004 V = 2008
B = February F = June K = October M = 2001 S = 2005 W = 2009
C = March G = July L = November N = 2002 T = 2006
D = April H = August M = December P = 2003 U = 2007