DOC: FS 12569 REVISED: 140113
HYDROSTATIC PRESSURE TRANSDUCER
FPC-12569
Functional Overview
39mm
93mm 19mm 28mm
25mm
7.4mm
- Pressure Range: 0-0.1bar (0-1m)
- Small body diameter - 39mm
- Excellent repeatability and long term stability
- Excellent anti-interference ability
- Application: depth or level measurement in wells, open water
and ground water level measurement
Features
Dimensions
Thank you for purchasing the MATelec Hydrostatic Pressure Transducer.
This unit is designed to be used for both potable/raw/rain water and waste
water applications. The unit is suited to 4-20mA applications where precise
level readings are required.
Pressure Range: Gauge pressure: 0-0.1bar (0-1m)
Level Range: 0m-200m (site dependent)
Overload Pressure: 1.5 times full scale
Accuracy: 0.5% F.S
Supply Voltage: 12~30Vdc ; 24Vdc
Output Signals: 4~20mA
Temperature Ranges: Compensated Temperature: 0~50°C
Media: -10~70°C
Environment: -30~85°C
Storage: -40~125°C
Temperature Compensation: 0.02%F.S./°C
Electrical Connection: Vented Cable
Protection Classication: Sensor is IP68
Vibration: 20g ; 20~5000HZ
Housing Material: 316 Stainless Steel
Operating Life: >1x108Pressure Cycles
Specications
MATelec reserves the right to alter any technical data without notice.
®
ATelec
AUSTRALIA
DOC: FS 12569 REVISED: 140113
HYDROSTATIC PRESSURE TRANSDUCER
FPC-12569
®
ATelec
AUSTRALIA
Installation Guide
MATelec reserves the right to alter any technical data without notice.
100mm
(MIN)
50mm
(MIN)
1 2 3 45
Installing a Hydrostatic Transducer | FSW-12570
OPEN
OPEN
Hanging
Point
Nylon
Clamp
CLOSE
CLOSE
100mm
(MIN)
50mm
(MIN)
1 2 3 45
Installing a Hydrostatic Transducer | FSW-12570
OPEN
OPEN
Hanging
Point
Nylon
Clamp
CLOSE
CLOSE
100mm
(MIN)
50mm
(MIN)
1 2 3 45
Installing a Hydrostatic Transducer | FSW-12570
OPEN
OPEN
Hanging
Point
Nylon
Clamp
CLOSE
CLOSE
100mm
(MIN)
50mm
(MIN)
1 2 3 45
Installing a Hydrostatic Transducer | FSW-12570
OPEN
OPEN
Hanging
Point
Nylon
Clamp
CLOSE
CLOSE
100mm
(MIN)
50mm
(MIN)
1 2 3 45
Installing a Hydrostatic Transducer | FSW-12570
OPEN
OPEN
Hanging
Point
Nylon
Clamp
CLOSE
CLOSE
1. Ensure hook or similar bracket
(supplied by others) is installed, for
clamp to hang from.
2. Move nylon clamps up to enable
Cable Receptor to open.
3. Place cable in clamp
ensuring it is aligned
with cable groove.
4. Move clamps down to ensure
cable is securely held/clamped.
Care must be taken to ensure
Transducer position is correct.
(Refer Fig. 5)
5. Hang bracket on hook.
The weight of the transducer will ensure the clamps
continue to hold the cable.
Excess cable must be coiled neatly ensuring no kinks
obstruct internal Air Tube.

Other Matelec Transducer manuals

Matelec FPC-12570 User manual

Matelec

Matelec FPC-12570 User manual

Matelec FPC-12571 User manual

Matelec

Matelec FPC-12571 User manual

Matelec FPC-12572 User manual

Matelec

Matelec FPC-12572 User manual

Popular Transducer manuals by other brands

Kele UCS-621 quick start guide

Kele

Kele UCS-621 quick start guide

Camille Bauer SINEAX U 554 operating instructions

Camille Bauer

Camille Bauer SINEAX U 554 operating instructions

Raymarine HYPERVISIONT HV-300 Series installation instructions

Raymarine

Raymarine HYPERVISIONT HV-300 Series installation instructions

Lowrance 000-15275-001 installation guide

Lowrance

Lowrance 000-15275-001 installation guide

Simrad ES38-10 - INSTALLATION REV H installation manual

Simrad

Simrad ES38-10 - INSTALLATION REV H installation manual

Kobold MM Series operating instructions

Kobold

Kobold MM Series operating instructions

GEM 3240 operating instructions

GEM

GEM 3240 operating instructions

halstrup-walcher PIZ instruction manual

halstrup-walcher

halstrup-walcher PIZ instruction manual

Setra Systems Multi-Sense 231RS operating instructions

Setra Systems

Setra Systems Multi-Sense 231RS operating instructions

Dossena FL Series quick start guide

Dossena

Dossena FL Series quick start guide

M-system 18PA instruction manual

M-system

M-system 18PA instruction manual

Siemens SITRANS 7ML1100 Compact operating instructions

Siemens

Siemens SITRANS 7ML1100 Compact operating instructions

Airmar R109LH Owner's guide and installation instructions

Airmar

Airmar R109LH Owner's guide and installation instructions

Airmar P79 Owner's guide & installation instructions

Airmar

Airmar P79 Owner's guide & installation instructions

t.a.c. CP-8551 General instructions

t.a.c.

t.a.c. CP-8551 General instructions

Furuno 165T/265LH Owner's guide and installation instructions

Furuno

Furuno 165T/265LH Owner's guide and installation instructions

Airmar Shorty P6 Owner's guide & installation instructions

Airmar

Airmar Shorty P6 Owner's guide & installation instructions

Electro-Voice DH2T-16 Technical specifications

Electro-Voice

Electro-Voice DH2T-16 Technical specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.