MAX LIGHT USB-SP02A User manual

Product : 2 Port Slim Palmtop USB KVM Switch
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Trade Name : UNICLASS
Model No. : USB-SP02A/USB-SP02
Sample Received Date : Nov 12, 2005
Report No. : MLT0512EMC002
Prepared by :
Approved by :
Jesse Tien
Roger Chen
Test By Max Light Technology Co., Ltd.
Room 5, 8F, No.125, Section 3 Roosevelt Road,
Taipei, Taiwan., R.O.C.
Tel: 886-2-2363-2447 Fax: 886-2-2363-2597
T
Th
he
e
t
te
es
st
t
r
re
ep
po
or
rt
t
c
co
on
ns
si
is
st
ts
s
o
of
f
6
68
8
p
pa
ag
ge
es
s
i
in
n
t
to
ot
ta
al
l.
.
I
It
t
m
ma
ay
y
b
be
e
d
du
up
pl
li
ic
ca
at
te
ed
d
c
co
om
mp
pl
le
et
te
el
ly
y
f
fo
or
r
l
le
eg
ga
al
l
u
us
se
e
w
wi
it
th
h
t
th
he
e
a
al
ll
lo
ow
wa
an
nc
ce
e
o
of
f
t
th
he
e
a
ap
pp
pl
li
ic
ca
an
nt
t.
.
I
It
t
s
sh
ha
al
ll
l
n
no
ot
t
b
be
e
r
re
ep
pr
ro
od
du
uc
ce
ed
d
e
ex
xc
ce
ep
pt
t
i
in
n
f
fu
ul
ll
l,
,
w
wi
it
th
ho
ou
ut
t
t
th
he
e
w
wr
ri
it
tt
te
en
n
a
ap
pp
pr
ro
ov
va
al
l
o
of
f
o
ou
ur
r
l
la
ab
bo
or
ra
at
to
or
ry
y.
.

MAX LIGHT
MEASUREMENT REPORT Page: 2/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
Table of Contents :
I. Description of EUT 3.
II. Evaluation 4.
III. Conducted/Radiated Emissions Requirements (EMI) 5.
IV. Harmonics/Voltage Fluctuation and Flicker Test 14.
V. Electrostatic Discharge Requirements 20.
VI. Radiated Electromagnetic Field Requirements 29.
VII. Electrical Fast Transient/Burst Requirements 32.
VIII. Surge Requirements 35.
IX. Immunity to Conducted Disturbances, Induced by Frequency Field 38.
X. Voltage Dips, Short Interruptions and Voltage Variations Requirements 41.
Appendix I (EUT Test Setup) 44.
Appendix II (Users Manual) 53.
Appendix III (Schematic Diagram) 54.
Appendix IV (EUT Photographs) 55.

MAX LIGHT
MEASUREMENT REPORT Page: 3/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
I. Description of EUT
1.1 Identification of EUT
Equipment : 2 Port Slim Palmtop USB KVM Switch
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
4F, No. 98, Ming Chuan Rd.,
Hsintien, Taipei, Taiwan
Manufacturer : UNICLASS TECHNOLOGY CO., LTD.
4F, No. 98, Ming Chuan Rd.,
Hsintien, Taipei, Taiwan
Model No : USB-SP02A/USB-SP02
1.2 Technical data of EUT
Input Rating : Powered By PC(Via +5Vdc)
1.3 Configuration of EUT
This 2 Port Slim Palmtop USB KVM Switchconsists of
Item Component Manufacturer Model
1. Computer COMPAQ EVO D300
2. Keyboard IBM HDF-912
3. Monitor SONY SDM-HS74
4. Mouse IBM 10L6144
5. Printer PANASONIC KX-P10801
6. Modem ASKEY WS1414SV

MAX LIGHT
MEASUREMENT REPORT Page: 4/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
II. Evaluation
According to Results
EN 55022: 1998 +A1: 2000 +A2: 2003 (Class B) Pass
EN61000-3-2: 2000 Pass
EN61000-3-3: 1995 +A1: 2001 Pass
EN 55024: 1998+A1: 2001+A2: 2003
EN 61000-4-2: 1995+A1: 1998+A2: 2001 Criterion B
EN 61000-4-3: 2002+A1: 2002 Criterion A
EN 61000-4-4: 1995+A1: 2001+A2: 2001 Criterion B
EN 61000-4-5: 1995+A1: 2001 Criterion B
EN 61000-4-6: 1996+A1: 2001 Criterion A
EN 61000-4-11: 2004 Criterion B & Criterion C
Criterion A: The equipment shall continue to operate as intended without
operator intervention.
Criterion B: After the test, the equipment shall continue to operate as
intended without operator intervention. During the test,
degradation of performance is allowed. However, no change of
operating state or stored data is allowed to persist after test.
Criterion C: Loss of function is allowed, provide the function is
self-recoverable, or can be restored by the operation of the
control s by the user in accordance with the manufacturer’s
instructions.
* EN 55024: 1998+A1: 2001+A2: 2003 Information technology equipment-
Immunity characteristics- Limits and
methods of measurement
Test Center: Max Light Technology Co., Ltd.
Remark : The test results only relate to the submitted test sample
specified above.

MAX LIGHT
MEASUREMENT REPORT Page: 5/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
III. Conducted/Radiated Emissions Requirements (EMI)
3.1 General:
The conducted emissions test from 150KHz to 30MHz is employed to the
power line through a LISN (Line Impedance Stabilization Network). The
limits are 66-56dBuV(QP) / 56-46dBuV(Average), decreases linearly with the
logarithm for 0.15-0.50MHz; 56dBuV(QP)/ 46dBuV(Average) for
0.50MHz-5MHz; 60dBuV(QP) / 50dBuV(Average) for 5-30MHz.
The conducted emissions test from 150KHz to 30MHz is employed to the
telecommunication port through a ISN (Impedance Stabilization Network) or
Current Probe . The Voltage limits are 84-74dBuV(QP) / 74-64dBuV(Average),
decreases linearly with the logarithm for 0.15-0.50MHz; 74dBuV(QP)/
64dBuV(Average) for 0.50MHz-30MHz; Current limits are 40-30dBuV(QP) /
30-20dBuV(Average), decreases linearly with the logarithm for
0.15-0.50MHz; 30dBuV(QP)/ 20dBuV(Average) for 0.50MHz-30MHz;
The radiated emissions test is made at a 10 meters open site from 30MHz
to 1000MHz. The object of this test is to investigate the emissions from the
EUT in order to suppress interference to the environment. The limits are
30dBuV/m(QP) for 30-230MHz; 37dBuV/m(QP) for 230-1000MHz.
3.2 Test Specifications:
Requirement Comment Result (Pass/Fail)
EN 55022 Class B Conducted Emission 0.15-30 MHz
(Main Power Port) Pass
EN 55022 Class B Conducted Emission 0.15-30 MHz
(Telecommunication Port) N/A
EN 55022 Class B Radiated Emission 30-1000 MHz Pass
3.3 Setup:
The EUT is placed on a support of non-metallic, the height of which is
0.8m above the ground. For the conducted test, a LISN is used as a
matching network to the measuring receiver. The EUT is rotated and the
antenna's height vary between 1m and 4m for horizontal and vertical
polarization to obtain the maximum reading during the radiated test.

MAX LIGHT
MEASUREMENT REPORT Page: 6/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
3.4 Test Equipment List:
A. EMCO 3825/2 LISN (S/N:2654)
B. EMCO 3825/2 LISN (S/N:2658)
C. Schaffner T411 ISN (S/N:A432)
D. HP 8591EM 9KHZ-1.8GHz Spectrum Analyzer (S/N:73412A00110)
E. Shielded Room (MLT-SR1)
F. HP 8591EM 9KHz-1.8GHz Spectrum Analyzer (S/N:73412A00230)
G. HP 8447D Pre Amplifier (S/N:2944A08954)
H. EMCO 3142 Biconilog Antenna (S/N:1184)
I. HP 8590A 10KHz-1.5GHz Spectrum Analyzer (S/N:5212A000211)
J. HP 9872B Plotter (S/N:20447A03436)
K. R&S ESH3 Test Receiver (S/N:892108/025)
L. R&S ESVP Test Receiver (S/N:881121/010)
3.5 Test condition:
EUT tested in accordance with the specifications given by the
manufacturer , and exercised in the most unfavorable manner.
3.6 Conducted Emissions Limits (Mains ports) :
Limits (dBuV)
Frequency range
(MHz) Quasi-peak Average
0.15 to 0.50 66 to 56 56 to 46
0.50 to 5.0 56 46
5.0 to 30 60 50
3.7 Conducted Emissions Limits (Telecommunication Port):
Voltage Limits (dBuV)
Frequency range
(MHz) Quasi-peak Average
0.15 to 0.50 84 to 74 74 to 64
0.50 to 30 74 64

MAX LIGHT
MEASUREMENT REPORT Page: 7/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
3.8 Conducted Emissions Limits (Telecommunication Port):
Current Limits (dBuV)
Frequency range
(MHz) Quasi-peak Average
0.15 to 0.50 40 to 30 30 to 20
0.50 to 30 30 20
3.9 Radiated Emissions Limits:
Frequency range (MHz) Quasi-peak (dBuV/m)
30 to 230 30
230 to 1000 37

MAX LIGHT
MEASUREMENT REPORT Page: 8/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
3.10 Measurement Data Of Conducted Emissions:
3.10.1 Conducted Emissions (Mains Power)
The following table show a summary of the highest emissions of
power line conducted emissions to the HOT and NEUTRAL conductor of the
EUT power.
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 12/21/2005
Power Line Conducted Emissions (Class B)
Conductor Frequency
(MHz) Quasi-Peak
(dBuV) Limits Average
(dBuV) Limits
0.22 43.69 62.66 -- 52.66
0.56 37.00 56 -- 46
0.68 39.94 56 -- 46
L1 1.38 46.93 56 38.69 46
4.77 47.21 56 34.98 46
7.65 50.06 60 40.65 50
16.05 49.19 60 38.69 50
0.22 42.33 62.66 -- 42.66
0.56 36.70 56 -- 46
0.80 38.06 56 -- 46
L2 1.15 41.54 56 -- 46
4.36 39.26 56 -- 46
16.05 47.44 60 -- 50
24.14 39.54 60 -- 50
Notes : 1.L1: One end & Ground L2: The other end & Ground
2.Height of table on which the EUT was placed : 0.8 m.
3.The Quasi-Peak Value have already met the Average
Value Limit showed on above limits.
4.The above test results are obtained under the normal
condition.

MAX LIGHT
MEASUREMENT REPORT Page: 9/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
3.10.2 Conducted Emissions (Mains Power)
The following table show a summary of the highest emissions of
power line conducted emissions to the HOT and NEUTRAL conductor of the
EUT power.
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02A
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 12/21/2005
Power Line Conducted Emissions (Class B)
Conductor Frequency
(MHz) Quasi-Peak
(dBuV) Limits Average
(dBuV) Limits
0.24 51.68 61.78 40.80 51.78
1.03 46.00 56 40.80 46
1.16 45.73 56 41.50 46
L1 1.29 45.99 56 39.90 46
1.95 43.55 56 -- 46
4.31 42.90 56 -- 46
4.72 43.93 56 -- 46
0.24 50.63 61.78 39.40 51.78
1.03 45.62 56 40.60 46
1.15 45.56 56 41.20 46
L2 1.29 45.02 56 39.50 46
1.42 42.91 56 -- 46
1.94 42.98 56 -- 46
2.51 42.41 56 -- 46
Notes : 1.L1: One end & Ground L2: The other end & Ground
2.Height of table on which the EUT was placed : 0.8 m.
3.The Quasi-Peak Value have already met the Average
Value Limit showed on above limits.
4.The above test results are obtained under the normal
condition.

MAX LIGHT
MEASUREMENT REPORT Page: 10/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
3.11 Measurement Data Of Radiated Emissions:
3.11.1 Open Field Radiated Emissions (HORIZONTAL)
The highest peak values of radiated emissions from the EUT at
various antenna heights, antenna polarization, EUT orientation , etc. are
recorded on the following.
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 01/11/2006
Radiated Emissions (HORIZONTAL)
Frequency
(MHz) Amplitude
(dBuV/m) Limits(Class B)
(dBuV/m) Margin
(dB)
73.58 26.56 30 -3.44
136.55 25.25 30 -4.75
192.01 24.77 30 -5.23
200.00 25.46 30 -4.54
431.11 31.68 37 -5.03
610.10 31.80 37 -5.20
647.00 32.17 37 -4.83
678.80 31.11 37 -5.89
914.00 32.70 37 -4.30
Notes : 1.Margin= Amplitude - Limits
2.Distance of Measurement : 10 Meter (30-1000MHz)
3.Height of table for EUT placed: 0.8 Meter.
4.Amplitude= Reading Amplitude –Amplifier gain+ Cable loss
+Antenna factor
(Auto calculate in spectrum analyzer)

MAX LIGHT
MEASUREMENT REPORT Page: 11/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
3.11.2 Open Field Radiated Emissions (VERTICAL)
The highest peak values of radiated emissions from the EUT at
various antenna heights, antenna polarization, EUT orientation , etc. are
recorded on the following.
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 01/11/2006
Radiated Emissions (VERTICAL)
Frequency
(MHz)
Amplitude
(dBuV/m) Limits(Class B)
(dBuV/m) Margin
(dB)
49.13 28.56 30 -1.44
73.65 28.63 30 -1.37
85.93 26.50 30 -3.50
92.42 26.18 30 -3.82
120.03 27.29 30 -2.71
138.02 28.73 30 -1.27
183.54 27.20 30 -2.80
192.01 28.23 30 -1.77
828.50 32.19 37 -4.81
Notes : 1.Margin= Amplitude - Limits
2.Distance of Measurement : 10 Meter (30-1000MHz)
3.Height of table for EUT placed: 0.8 Meter.
4.Amplitude= Reading Amplitude –Amplifier gain+ Cable loss
+Antenna factor
(Auto calculate in spectrum analyzer)

MAX LIGHT
MEASUREMENT REPORT Page: 12/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
3.11.3 Open Field Radiated Emissions (HORIZONTAL)
The highest peak values of radiated emissions from the EUT at
various antenna heights, antenna polarization, EUT orientation , etc. are
recorded on the following.
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02A
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 12/14/2006
Radiated Emissions (HORIZONTAL)
Frequency
(MHz) Amplitude
(dBuV/m) Limits(Class B)
(dBuV/m) Margin
(dB)
48.01 26.98 30 -3.02
89.66 26.84 30 -3.16
119.99 27.03 30 -2.97
139.26 25.58 30 -4.42
142.52 27.10 30 -5.03
191.99 28.51 30 -1.49
216.02 24.98 30 -5.02
360.03 32.87 37 -4.13
648.03 32.85 37 -4.15
Notes : 1.Margin= Amplitude - Limits
2.Distance of Measurement : 10 Meter (30-1000MHz)
3.Height of table for EUT placed: 0.8 Meter.
4.Amplitude= Reading Amplitude –Amplifier gain+ Cable loss
+Antenna factor
(Auto calculate in spectrum analyzer)

MAX LIGHT
MEASUREMENT REPORT Page: 13/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
3.11.4 Open Field Radiated Emissions (VERTICAL)
The highest peak values of radiated emissions from the EUT at
various antenna heights, antenna polarization, EUT orientation , etc. are
recorded on the following.
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02A
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 12/14/2006
Radiated Emissions (VERTICAL)
Frequency
(MHz)
Amplitude
(dBuV/m) Limits(Class B)
(dBuV/m) Margin
(dB)
48.01 25.76 30 -4.24
75.36 24.27 30 -5.73
90.30 26.20 30 -3.80
139.29 26.48 30 -3.52
168.02 25.09 30 -4.91
179.76 25.98 30 -4.02
191.99 26.46 30 -3.54
216.02 25.35 30 -4.65
765.48 31.73 37 -5.27
Notes : 1.Margin= Amplitude - Limits
2.Distance of Measurement : 10 Meter (30-1000MHz)
3.Height of table for EUT placed: 0.8 Meter.
4.Amplitude= Reading Amplitude –Amplifier gain+ Cable loss
+Antenna factor
(Auto calculate in spectrum analyzer)

MAX LIGHT
MEASUREMENT REPORT Page: 14/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
IV. Harmonics/Voltage Fluctuation and Flicker Test
4.1 General:
This standard is applicable to electrical and electronic equipment for
household and similar use, intended to be connected to low-voltage A.C
distribution system of the following types:
nominal voltages up to 240V, single-phase, two or tree wire;
nominal voltages up to 415V, three-phase, three or four wire;
nominal frequency 50 Hz or 60Hz
Examples of electrical equipment to which this standard applies
are appliances for cooking and heating, motor-operated or magnetically
driven appliance, portable tools, light dimmers and radio and television
receivers.
This standard is not applicable to :
equipment subject to notification to or consent by the supply
authority before connection to the system;
equipment intended exclusively for professional purposes.
4.2 Test Specifications:
Requirement Comment Results (Pass/Fail)
EN 61000-3-2 Harmonic 0-2 KHz Pass
EN 61000-3-3 Flicker Pass
4.3 Setup:
Whether the equipment operates with automatic, mixed or manual
control, the measurements shall be made under normal load, or conditions
for adequate heat discharge, and under normal operating conditions.

MAX LIGHT
MEASUREMENT REPORT Page: 15/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
User’s operation controls or automatic programmer shall be set to
produce the maximum harmonic components, for each successive
harmonic component in turn.
A definition of the normal load or of the conditions for adequate heat
discharge can usually be found in the EN publication corresponding to the
equipment under test.
Equipment may have several separately controlled circuits. Each
circuit is considered as a single piece of equipment if it can be operated
independently and separately from the other circuits.
4.4 Test Equipment List:
EMC-Partner HAR1000-1P Power Harmonics Analyzers (S/N:076)
4.5 Test condition:
EUT tested in accordance with the specifications given by the
manufacturer , and exercised in the most unfavorable manner.
4.6 Measurement Data Of Harmonic:
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 12/21/2005
Classification : Class A
Input Voltage : 230.3V
Rms Amp : 0.384A
Real Power : 41.77W
Peak Amp : 1.835A
Apparent Power : 88.39VA
Power Factor : 0.473
Limits Multiplied by 1.00

MAX LIGHT
MEASUREMENT REPORT Page: 16/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
Measurement Data
Harmonic Order Limits Magnitude Results
(Pass/Fail)
2 1.080A 0.0056A Pass
3 2.300A 0.1860A Pass
4 0.430A 0.0054A Pass
5 1.140A 0.1735A Pass
6 0.300A 0.0050A Pass
7 0.770A 0.1564A Pass
8 0.230A 0.0045A Pass
9 0.400A 0.1350A Pass
10 0.184A 0.0040A Pass
11 0.330A 0.1116A Pass
12 0.153A 0.0035A Pass
13 0.210A 0.0875A Pass
14 0.131A 0.0031A Pass
15 0.150A 0.0647A Pass
16 0.115A 0.0027A Pass
17 0.132A 0.0447A Pass
18 0.102A 0.0023A Pass
19 0.118A 0.0288A Pass
20 0.092A 0.0021A Pass
21 0.107A 0.0164A Pass
22 0.084A 0.0017A Pass
23 0.098A 0.0089A Pass
24 0.077A 0.0015A Pass
25 0.090A 0.0081A Pass
26 0.071A 0.0012A Pass
27 0.083A 0.0093A Pass
28 0.066A 0.0010A Pass
29 0.078A 0.0094A Pass
30 0.061A 0.0007A Pass
31 0.073A 0.0082A Pass
32 0.058A 0.0006A Pass
33 0.068A 0.0063A Pass
34 0.054A 0.0005A Pass
35 0.064A 0.0048A Pass
36 0.051A 0.0004A Pass
37 0.061A 0.0035A Pass
38 0.048A 0.0002A Pass
39 0.058A 0.0029A Pass
40 0.046A 0.0002A Pass

MAX LIGHT
MEASUREMENT REPORT Page: 17/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
4.7 Measurement Result Of Flicker:
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 12/21/2005
Classification : Class A
Input Voltage : 230.3V
Rms Amp : 0.384A
Real Power : 41.77W
Peak Amp : 1.835A
Apparent Power : 88.39VA
Power Factor : 0.473
Test Equipment Setting
Line Voltage 229.9V/AC
Line Frequency 50Hz
Test Limit Overrides None
Total Number Of Failures Pst: (0), Plt: (0), Dc: (0), Dmax (0)m Dt (0)
Total Number Of Errors None
4.8 Measurement Data Of Harmonic:
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02A
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 12/16/2005
Classification : Class A
Input Voltage : 230.3V
Rms Amp : 0.415A
Real Power : 41.97W
Peak Amp : 2.114A
Apparent Power : 95.59VA
Power Factor : 0.439
Limits Multiplied by 1.00

MAX LIGHT
MEASUREMENT REPORT Page: 18/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
Measurement Data
Harmonic Order Limits Magnitude Results
(Pass/Fail)
2 1.080A 0.0031A Pass
3 2.300A 0.1709A Pass
4 0.430A 0.0021A Pass
5 1.140A 0.1633A Pass
6 0.300A 0.0024A Pass
7 0.770A 0.1526A Pass
8 0.230A 0.0024A Pass
9 0.400A 0.1385A Pass
10 0.184A 0.0027A Pass
11 0.330A 0.1230A Pass
12 0.153A 0.0027A Pass
13 0.210A 0.1056A Pass
14 0.131A 0.0024A Pass
15 0.150A 0.0876A Pass
16 0.115A 0.0024A Pass
17 0.132A 0.0699A Pass
18 0.102A 0.0021A Pass
19 0.118A 0.0531A Pass
20 0.092A 0.0021A Pass
21 0.107A 0.0385A Pass
22 0.084A 0.0018A Pass
23 0.098A 0.0256A Pass
24 0.077A 0.0015A Pass
25 0.090A 0.0150A Pass
26 0.071A 0.0012A Pass
27 0.083A 0.0070A Pass
28 0.066A 0.0012A Pass
29 0.078A 0.0058A Pass
30 0.061A 0.0009A Pass
31 0.073A 0.0082A Pass
32 0.058A 0.0009A Pass
33 0.068A 0.0098A Pass
34 0.054A 0.0009A Pass
35 0.064A 0.0101A Pass
36 0.051A 0.0009A Pass
37 0.061A 0.0095A Pass
38 0.048A 0.0009A Pass
39 0.058A 0.0079A Pass
40 0.046A 0.0006A Pass

MAX LIGHT
MEASUREMENT REPORT Page: 19/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
4.9 Measurement Result Of Flicker:
Applicant : UNICLASS TECHNOLOGY CO.,LTD.
Model No : USB-SP02A
EUT : 2 Port Slim Palmtop USB KVM Switch
Test Mode : Send H pattern
Test Date : 12/16/2005
Classification : Class A
Input Voltage : 230.3V
Rms Amp : 0.415A
Real Power : 41.97W
Peak Amp : 2.114A
Apparent Power : 95.59VA
Power Factor : 0.439
Test Equipment Setting
Line Voltage 229.9V/AC
Line Frequency 50Hz
Test Limit Overrides None
Total Number Of Failures Pst: (0), Plt: (0), Dc: (0), Dmax (0)m Dt (0)
Total Number Of Errors None

MAX LIGHT
MEASUREMENT REPORT Page: 20/68
Report Number: MLT0512EMC002 Issue Date:01/13/2006
Technology Lab
V.
Electrostatic Discharge Requirements (ESD)
5.1 General:
This requirement relates to the EUT may be involved static electricity
discharges owing to environmental and installation conditions. A transfer of
electrostatic charge between objects of different electrostatic potential
may cause harmful to the EUT. A performance Criterion is classified as A, B,
C the recommendation is Criterion B.
5.2 Test Specifications:
Requirement Basic Standard Performance
Criterion
EN 55024 EN 61000-4-2: 1995+A1: 1998+A2: 2001 Criterion B
Criterion A: The equipment shall continue to operate as intended without
operator intervention.
Criterion B: After the test, the equipment shall continue to operate as
intended without operator intervention. During the test,
degradation of performance is allowed. However, no change of
operating state or stored data is allowed to persist after test.
Criterion C: Loss of function is allowed, provide the function is
self-recoverable, or can be restored by the operation of the
control s by the user in accordance with the manufacturer’s
instructions.
5.3 Setup:
The discharge shall be applied in two ways:
1.Contact discharge to the conductive surfaces and coupling planes:
The EUT shall be exposed to at least 200 discharges, 100 each at
negative and positive polarity, at a minimum of four test points. One of
the test points shall be subjected to at least 50 indirect discharges to
the center of the front edge of horizontal coupling plane. Test shall be
performed at a maximum repetition rate of one discharge per second.
This manual suits for next models
1
Table of contents
Popular Switch manuals by other brands

Austin Hughes
Austin Hughes CV-801 user manual

IMC Networks
IMC Networks AccessEtherLinX Operation manual

Patton electronics
Patton electronics 360 user manual

Dataprobe
Dataprobe iBoot-G2S manual

roco
roco Z21 switch DECODER manual

Elsner
Elsner Corlo Touch KNX Technical specifications and installation instructions