Maxima GENEMAX 7000 IS User manual

GENEMAX 7000 IS
User Manual
SERIAL NUMBER M


INVERTER GENERATOR
Owner's Manual
GENEMAX 7000 IS
Tips-read this manual carefully before operating this generator.

4
GENEMAX 7000 IS GENEMAX 7000 IS

5
GENEMAX 7000 IS GENEMAX 7000 IS
Save this operating manual properly and carry it with the
generator for the convenience of emergency query in the
future. This manual constitutes one permanent element of the
generator. This manual shall be provided along with the
generator set when you lend or resell it.
Relevant information and technical specifications defined in
this manual take effect when printing is approved, with the
contents based on the equipment in production at time of
publication. Manufacturer reserves the rights to modify and
improve any parts described in the text without prior notice.
Original instruction

6
GENEMAX 7000 IS GENEMAX 7000 IS
01
01
20-21
02-07
08-19
22-26
27
28-38
39
40
41-42
43
44
45-48
Thank you for purchasing a generator.
read this manual carefully before use this generator, and fully comprehend
all requirements and operating procedure concerning the generator. In case
of any questions about this manual, contact the recent authorized dealer for
startup, operation, maintenance program and so on. The technician will
teach you how to use the generator in a correct and safe manner. We also
recommend that the operator consult startup and operating procedure of
this generator when buying it.
We recommend that the operator
Safety precautions
It is impossible for manufacturers to predict all hazardous circumstances
that may occur, for this reason, warnings in this manual and caution signs
on the generator set may not cover all hazardous circumstances. If we do
not give extra cautions for operating procedures, methods or techniques,
operate the generator in such ways that helps guarantee personal safety,
make sure no damage to generator set arises there from.
To make sure safe operation,Please read carefully three vital safety
warnings in this manual and on the generator, preceded by a safety alert
symbol including:
Foreward
Foreward
This generator will work in a safe, effective and reliable way only when it is
kept, operated and maintained properly. Before operation or maintenance
of the generator, the operator should:
Know well and strictly observe local laws and regulations.
Read and observe all safety warnings in this manual and on the device.
Let your family get familiar with all safety warnings in this manual.
!DANGER You WILL be KILLED or SERIOUSLY HURT if you don't
follow instructions.
!WARNING
!CAUTION
NOTICE
You CAN be KILLED or SERIOUSLY HURT if you don't
follow instructions.
You CAN be HURT if you don't follow instructions.
Your generator or other property could be damaged if you
don't follow instructions.
Inverter Generator Owner's Manual
Contents
1 Foreward
2 Safety Information
3 Control Function
4 Pre-oparation
5 Operation
7 Maintenance
6 Application Range
10 Storage
9 Transporting
8 Accessories Installation
11 Troubleshooting
12 P arameters
13 Electrical Schematic Diagram
07
08-13
14-25
26-27
28-32
33
34-44
39
47
48
49
50
51-54
45

7
GENEMAX 7000 IS GENEMAX 7000 IS
01
01
20-21
02-07
08-19
22-26
27
28-38
39
40
41-42
43
44
45-48
Thank you for purchasing a generator.
read this manual carefully before use this generator, and fully comprehend
all requirements and operating procedure concerning the generator. In case
of any questions about this manual, contact the recent authorized dealer for
startup, operation, maintenance program and so on. The technician will
teach you how to use the generator in a correct and safe manner. We also
recommend that the operator consult startup and operating procedure of
this generator when buying it.
We recommend that the operator
Safety precautions
It is impossible for manufacturers to predict all hazardous circumstances
that may occur, for this reason, warnings in this manual and caution signs
on the generator set may not cover all hazardous circumstances. If we do
not give extra cautions for operating procedures, methods or techniques,
operate the generator in such ways that helps guarantee personal safety,
make sure no damage to generator set arises there from.
To make sure safe operation,Please read carefully three vital safety
warnings in this manual and on the generator, preceded by a safety alert
symbol including:
Foreward
Foreward
This generator will work in a safe, effective and reliable way only when it is
kept, operated and maintained properly. Before operation or maintenance
of the generator, the operator should:
Know well and strictly observe local laws and regulations.
Read and observe all safety warnings in this manual and on the device.
Let your family get familiar with all safety warnings in this manual.
!DANGER You WILL be KILLED or SERIOUSLY HURT if you don't
follow instructions.
!WARNING
!CAUTION
NOTICE
You CAN be KILLED or SERIOUSLY HURT if you don't
follow instructions.
You CAN be HURT if you don't follow instructions.
Your generator or other property could be damaged if you
don't follow instructions.
Inverter Generator Owner's Manual
Contents
1 Foreward
2 Safety Information
3 Control Function
4 Pre-oparation
5 Operation
7 Maintenance
6 Application Range
10 Storage
9 Transporting
8 Accessories Installation
11 Troubleshooting
12 P arameters
13 Electrical Schematic Diagram

8
GENEMAX 7000 IS GENEMAX 7000 IS
03
Safety Information
Safety Information
Safety Information
Inverter Generator Owner's Manual
Inverter Generator Owner's Manual
Keep children and pets away
from the area of operation.
Do not place flammable objects
close to the outlet valve when
generator operation.
Keep it at least 1m away from
inflammables.
Keep the machine clean and
avoid spilt combustibles
including gasoline on it.
Do not use it in a wet condition.
Do not use it indoors.
Turn the generator “OFF''
when add fuel.
Don't add fuel near the
flammable thing or cigarette.
!WARNING
!WARNING
!WARNING
!WARNING
!DANGER
!DANGER

9
GENEMAX 7000 IS GENEMAX 7000 IS
0302
Safety Information
Safety Information
Safety Information
Inverter Generator
Owner's Manual
Inverter Generator
Owner's Manual
Keep children and pets away
from the area of operation.
Do not place flammable objects
close to the outlet valve when
generator operation.
Keep it at least 1m away from
inflammables.
Keep the machine clean and
avoid spilt combustibles
including gasoline on it.
Do not use it in a wet condition.
Do not use it indoors.
Turn the generator “OFF''
when add fuel.
Don't add fuel near the
flammable thing or cigarette.
!WARNING
!WARNING
!WARNING
!WARNING
!DANGER
!DANGER

10
GENEMAX 7000 IS GENEMAX 7000 IS
0504
!WARNING
!WARNING
!WARNING
The generator surface has high
temperature, avoid scalding.
Pay attention to the warnings
on the generating set.
It must realize safe grounding.
NOTICE Use the ground wire
with enough electric
flux.
Ground wire diameter:0.12mm/A
EX:10A-1.2mm
Do not connect to a home
power system.
Connection to a home power supply
If the generator is to be connected to a home power supply as a standby,
connection shall be performed by a professional electrician or by another
person with proficient electrical skill.
When the loads are connected to the generator, please carefully check
whether electrical connections are safe and reliable. Any improper
connection may cause damage to the generator, or cause a fire.
Make sure Inverter ducted fan, muffler louver and the inverter bottom
side cooling well and without chips, mud and water come in. it may
damage the generator, inverter or alternator if the cooling vent blocked.
Do not mix the generator with other stuff if moving, storing or running the
unit, It may cause generator damage or bring property safety issue when
the inverter in leakage.
Others
RIGHT
WRONG RIGHT
Inverter Generator
Owner's Manual
Inverter Generator
Owner's Manual
Safety Information
Safety Information

11
GENEMAX 7000 IS GENEMAX 7000 IS
0504
!WARNING
!WARNING
!WARNING
The generator surface has high
temperature, avoid scalding.
Pay attention to the warnings
on the generating set.
It must realize safe grounding.
NOTICE Use the ground wire
with enough electric
flux.
Ground wire diameter:0.12mm/A
EX:10A-1.2mm
Do not connect to a home
power system.
Connection to a home power supply
If the generator is to be connected to a home power supply as a standby,
connection shall be performed by a professional electrician or by another
person with proficient electrical skill.
When the loads are connected to the generator, please carefully check
whether electrical connections are safe and reliable. Any improper
connection may cause damage to the generator, or cause a fire.
Make sure Inverter ducted fan, muffler louver and the inverter bottom
side cooling well and without chips, mud and water come in. it may
damage the generator, inverter or alternator if the cooling vent blocked.
Do not mix the generator with other stuff if moving, storing or running the
unit, It may cause generator damage or bring property safety issue when
the inverter in leakage.
Others
RIGHT
WRONG RIGHT
Inverter Generator
Owner's Manual
Inverter Generator
Owner's Manual
Safety Information
Safety Information

12
GENEMAX 7000 IS GENEMAX 7000 IS
0706
Inverter Generator
Owner's Manual
Inverter Generator
Owner's ManualInverter Generator
Owner's Manual
Inverter Generator
Owner's Manual
Safety Information
Safety Information
There is the warning label on the machine to remind you of the
safety regulations.
Using a generator indoors CAN KILL YOU IN
MINUTES.Generator exhaust contains carbon
monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or
garage. EVEN IF doors and
windows are open.
Only use OUTSIDE and far
away from windows, doors,
and vents.
Due to high voltage of Generator
Do not connect to any building electrical system.
Do not overload generator.
Non-qualified person (including under-aged
children) is not allowed to operate.
Read owners manual carefully for important
safety and health warnings and instructions.
Understand and follow warnings and cau tio ns.
Do not operate unless guards are in place.
Generator exhaust contains hazardous CO.
Do not operate indoors and try to operate in
well ventilated area.
Gasoline and its vapor are flammable and
expl osi ve. Keep gasoline away from heat,
sparks, a nd flame s our ces.
Generators produce electricity that can cause
serious injury or death.
Operate only in dry areas away from moisture,
rain,snow or standing water.
Read the safety instructions before using the
generator.
Gases such as carbon monoxide (colourless
and odourless gas) are produced during
operation which may lead to suffocation.
Only use the generator in well-ventilated
areas.
Some parts of equipment will generate high
temperature during operation, which will scald skin.
Warning! Dangerous voltages are present
when the generator is in operation.
Generator must always be switched off
before performing maintenance works.
Wear ear protection when operating the
generator.
Disconnect all devices from the connections
before performing maintenance works,
before leaving the device and after
switching it off.
Only fill the generator in well-ventilated areas
and keep it away from open flames, sparks and
cigarettes. Spilled fuel should be soaked up
immediately.
Switch off the engine and let it cool down
before filling the generator. Fuel is easily
flammable and may even explode under
certain circumstances.
!WARNING A warning reminding the user that he shall conform to
regulations of electrical safety applicable to the place
where the generating sets are used.
A warning on the requirements and the precautions to be
respected by the user in the case of re-supply by
generating sets of an installation, depending on existing
protective measures in this installation and applicable
regulations.

13
GENEMAX 7000 IS GENEMAX 7000 IS
0706
Inverter Generator
Owner's Manual
Inverter Generator
Owner's ManualInverter Generator
Owner's Manual
Inverter Generator
Owner's Manual
Safety Information
Safety Information
There is the warning label on the machine to remind you of the
safety regulations.
Using a generator indoors CAN KILL YOU IN
MINUTES.Generator exhaust contains carbon
monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or
garage. EVEN IF doors and
windows are open.
Only use OUTSIDE and far
away from windows, doors,
and vents.
Due to high voltage of Generator
Do not connect to any building electrical system.
Do not overload generator.
Non-qualified person (including under-aged
children) is not allowed to operate.
Read owners manual carefully for important
safety and health warnings and instructions.
Understand and follow warnings and cau tio ns.
Do not operate unless guards are in place.
Generator exhaust contains hazardous CO.
Do not operate indoors and try to operate in
well ventilated area.
Gasoline and its vapor are flammable and
expl osi ve. Keep gasoline away from heat,
sparks, a nd flame s our ces.
Generators produce electricity that can cause
serious injury or death.
Operate only in dry areas away from moisture,
rain,snow or standing water.
Read the safety instructions before using the
generator.
Gases such as carbon monoxide (colourless
and odourless gas) are produced during
operation which may lead to suffocation.
Only use the generator in well-ventilated
areas.
Some parts of equipment will generate high
temperature during operation, which will scald skin.
Warning! Dangerous voltages are present
when the generator is in operation.
Generator must always be switched off
before performing maintenance works.
Wear ear protection when operating the
generator.
Disconnect all devices from the connections
before performing maintenance works,
before leaving the device and after
switching it off.
Only fill the generator in well-ventilated areas
and keep it away from open flames, sparks and
cigarettes. Spilled fuel should be soaked up
immediately.
Switch off the engine and let it cool down
before filling the generator. Fuel is easily
flammable and may even explode under
certain circumstances.
!WARNING A warning reminding the user that he shall conform to
regulations of electrical safety applicable to the place
where the generating sets are used.
A warning on the requirements and the precautions to be
respected by the user in the case of re-supply by
generating sets of an installation, depending on existing
protective measures in this installation and applicable
regulations.

14
GENEMAX 7000 IS GENEMAX 7000 IS
DIGITAL DISPLAY MET ER
USB
Turb
(1) (2) (3) (4) (5) (6) (7)
(8)(9)
(13) (10)(11)(12)(14)
(15)
DC 12V 8. 3A
PARALLEL OUTLETS
AC BREAKER
AC BREAKER
AC 120V/240V
AC 120V
AC 120V
AC 120V
VOLTAGE
SELECTOR
ENGIN E START
4 in 1 ENGI NE START
ON
OFF
ON
ESC
THROTTLE
GROUN D
Inverter Generator
Owner's Manual
0908
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8) (9)
(11)
(12)
(10)
(13)
(14)
(15)
(16)
(17) (18) (19)
(20)
(21)
(23)
(22)
120V/240V
120V/240V(Parallel socket with 50A)
Inverter Generator
Owner's Manual
Control Function
Inverter Generator
Owner's Manual
Control Function
Control Function
DESCRIPTION
Serial number
T***YYMM*******
The YYMM is year
and month of
manufactured.
CONTROL PANEL
(1)
(2)
(3) Cover plate of oil level sensor
(4) Frame components
(5) Control panel
(6) Folding handle
(7) Battery maintenance cover
(8) Frame shock absorber
bracket (right)
(9) Panel bed
(10) Support wheel parts
(11) Right maintenance door
(12) Seal ring (fuel tank)
(13) Tank hood (back)
(14) Frame hood
(15) Handle
(16) Silencer spark collector
(17) Carbon tank
(18) Air filter
(19) Frame shock absorber
bracket (left)
(20) Left maintenance door
(21) Spark plug
(22) Combination switch
(23) Tank hood (front)
Fuel tank
Fuel tank cap
(1)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
Digital display meter
(2) DC socket
Parallel outlets
AC breaker
AC breaker
AC socket
Grounding terminal
Esc throttle
4 in 1 Engine start
Engine start
Voltage selector
USB charging port
DC protection
(with parallel
unit)
AC socket
AC socket
(1)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
Digital display meter
(2) Voltage selector
AC breaker
AC breaker
AC breaker
Parallel outlets
AC socket
Grounding terminal
AC socket
Esc throttle
4 in 1 Engine start
Engine start
AC socket
USB charging port
AC socket
(1) (2) (3) (4) (5) (6) (7)
TTEESSTT
TTEESSTT
RREESSEETT
RREESSEETT
TTEESSTT
TTEESSTT
RREESSEETT
RREESSEETT
USB
Turb
(8)(9)(10)(11)(12)(13)(14)
(15) DIGITAL DISPLAY MET ER
VOLTAGE
SELECTOR
AC BREAKER
AC BREAKER AC BREAKER PARALLEL OUTLETS
AC 120V/240V
AC 120V/240V
AC 120V
AC 120V
AC 120V
ENGIN E START
4 in 1 ENGI NE START
ESC
THROT TLE
ON
OFF
GROUND

15
GENEMAX 7000 IS GENEMAX 7000 IS
DIGITAL DISPLAY MET ER
USB
Turb
(1) (2) (3) (4) (5) (6) (7)
(8)(9)
(13) (10)(11)(12)(14)
(15)
DC 12V 8. 3A
PARALLEL OUTLETS
AC BREAKER
AC BREAKER
AC 120V/240V
AC 120V
AC 120V
AC 120V
VOLTAGE
SELECTOR
ENGIN E START
4 in 1 ENGI NE START
ON
OFF
ON
ESC
THROTTLE
GROUN D
Inverter Generator
Owner's Manual
0908
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8) (9)
(11)
(12)
(10)
(13)
(14)
(15)
(16)
(17) (18) (19)
(20)
(21)
(23)
(22)
120V/240V
120V/240V(Parallel socket with 50A)
Inverter Generator
Owner's Manual
Control Function
Inverter Generator
Owner's Manual
Control Function
Control Function
DESCRIPTION
Serial number
T***YYMM*******
The YYMM is year
and month of
manufactured.
CONTROL PANEL
(1)
(2)
(3) Cover plate of oil level sensor
(4) Frame components
(5) Control panel
(6) Folding handle
(7) Battery maintenance cover
(8) Frame shock absorber
bracket (right)
(9) Panel bed
(10) Support wheel parts
(11) Right maintenance door
(12) Seal ring (fuel tank)
(13) Tank hood (back)
(14) Frame hood
(15) Handle
(16) Silencer spark collector
(17) Carbon tank
(18) Air filter
(19) Frame shock absorber
bracket (left)
(20) Left maintenance door
(21) Spark plug
(22) Combination switch
(23) Tank hood (front)
Fuel tank
Fuel tank cap
(1)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
Digital display meter
(2) DC socket
Parallel outlets
AC breaker
AC breaker
AC socket
Grounding terminal
Esc throttle
4 in 1 Engine start
Engine start
Voltage selector
USB charging port
DC protection
(with parallel
unit)
AC socket
AC socket
(1)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
Digital display meter
(2) Voltage selector
AC breaker
AC breaker
AC breaker
Parallel outlets
AC socket
Grounding terminal
AC socket
Esc throttle
4 in 1 Engine start
Engine start
AC socket
USB charging port
AC socket
(1) (2) (3) (4) (5) (6) (7)
T
T
E
E
S
S
T
T
T
T
E
E
S
S
T
T
R
R
E
E
S
S
E
E
T
T
R
R
E
E
S
S
E
E
T
T
T
T
E
E
S
S
T
T
T
T
E
E
S
S
T
T
R
R
E
E
S
S
E
E
T
T
R
R
E
E
S
S
E
E
T
T
USB
Turb
(8)(9)(10)(11)(12)(13)(14)
(15) DIGITAL DISPLAY MET ER
VOLTAGE
SELECTOR
AC BREAKER
AC BREAKER AC BREAKER PARALLEL OUTLETS
AC 120V/240V
AC 120V/240V
AC 120V
AC 120V
AC 120V
ENGIN E START
4 in 1 ENGI NE START
ESC
THROT TLE
ON
OFF
GROUND

16
GENEMAX 7000 IS GENEMAX 7000 IS
ENGIN E START
4 in 1 ENGI NE START
Turb
ESC
THROT TLE
ON
OFF
USB
50Hz 60Hz
(9)
(13) (10)(11)(12)(15)
(1) (2) (3) (4) (5) (6) (7)
(8)
(14)
(16)
VOLTAGE
SELECTOR
DIGITAL DISPLAY METER
AC BREAKER
AC BREAKER
AC 200V
AC 100V
AC 100V
AC 100V
GROUND
DC 12V 8. 3A
PARALLEL OUTLETS
Inverter Generator
Owner's Manual
230V
100V/200V
(1) (2) (3) (4) (5) (6) (7)
(8)
(11) (9)(10)(13) (12)
1110
Inverter Generator
Owner's Manual
Control Function
Inverter Generator
Owner's Manual
Control Function
CONTROL FUNCTION
4 in 1 switch knob
(1)
(3)
(4)
(5)
(6)
(7)
(8) F
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
Digital display meter
(2) DC socket
Parallel outlets
AC breaker
AC breaker
requency selection
AC socket
Grounding terminal
Esc throttle
4 in 1 Engine start
Engine start
Voltage selector
USB charging port
DC protection
(with parallel
unit)
AC socket
AC socket
DIGITAL DISPLAY MET ER
USB
DC 12V 8. 3A
ENGIN E START
4 in 1 ENGI NE START
PARALLEL OUTLETS
AC BREAKER
AC BREAKER
AC 230V
AC 230V
AC 230V
GROUN D
Turb
ESC
THROTTLE
ON
OFF
(1)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
Digital display meter
(2) DC socket
Parallel outlets
AC breaker
AC breaker
AC socket
Grounding terminal
Esc throttle
4 in 1 Engine start
Engine start
USB charging port
DC protection
(with parallel
unit)
AC socket
This switch controls ignition system,
fuel system, power system, and
solenoid valve.
Off -- stop the engine: Ignition system
is in the closed state, fuel switch is off,
solenoid valve switch is off, and power
system switch is off; the engine can't
be started normally.
On -- start/run the engine: Ignition
system is in the working state, fuel
switch is on, solenoid valve switch is
on, and power system switch is on.
The engine can be started with one
key by hand, and the Blue tooth APP
can be started and run normally.
When the combination switch is placed
in the “On” position, operate the start
switch button to start the engine.
One-key start switch
When the battery voltage is too low or
power loss is serious, and the power
fails to start normally, pull the recoil
starter to start the engine. .
Recoil starter

17
GENEMAX 7000 IS GENEMAX 7000 IS
ENGIN E START
4 in 1 ENGI NE START
Turb
ESC
THROT TLE
ON
OFF
USB
50Hz 60Hz
(9)
(13) (10)(11)(12)(15)
(1) (2) (3) (4) (5) (6) (7)
(8)
(14)
(16)
VOLTAGE
SELECTOR
DIGITAL DISPLAY METER
AC BREAKER
AC BREAKER
AC 200V
AC 100V
AC 100V
AC 100V
GROUND
DC 12V 8. 3A
PARALLEL OUTLETS
Inverter Generator
Owner's Manual
230V
100V/200V
(1) (2) (3) (4) (5) (6) (7)
(8)
(11) (9)(10)(13) (12)
1110
Inverter Generator
Owner's Manual
Control Function
Inverter Generator
Owner's Manual
Control Function
CONTROL FUNCTION
4 in 1 switch knob
(1)
(3)
(4)
(5)
(6)
(7)
(8) F
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
Digital display meter
(2) DC socket
Parallel outlets
AC breaker
AC breaker
requency selection
AC socket
Grounding terminal
Esc throttle
4 in 1 Engine start
Engine start
Voltage selector
USB charging port
DC protection
(with parallel
unit)
AC socket
AC socket
DIGITAL DISPLAY METER
USB
DC 12V 8. 3A
ENGIN E START
4 in 1 ENGI NE START
PARALLEL OUTLETS
AC BREAKER
AC BREAKER
AC 230V
AC 230V
AC 230V
GROUN D
Turb
ESC
THROTTLE
ON
OFF
(1)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
Digital display meter
(2) DC socket
Parallel outlets
AC breaker
AC breaker
AC socket
Grounding terminal
Esc throttle
4 in 1 Engine start
Engine start
USB charging port
DC protection
(with parallel
unit)
AC socket
This switch controls ignition system,
fuel system, power system, and
solenoid valve.
Off -- stop the engine: Ignition system
is in the closed state, fuel switch is off,
solenoid valve switch is off, and power
system switch is off; the engine can't
be started normally.
On -- start/run the engine: Ignition
system is in the working state, fuel
switch is on, solenoid valve switch is
on, and power system switch is on.
The engine can be started with one
key by hand, and the Blue tooth APP
can be started and run normally.
When the combination switch is placed
in the “On” position, operate the start
switch button to start the engine.
One-key start switch
When the battery voltage is too low or
power loss is serious, and the power
fails to start normally, pull the recoil
starter to start the engine. .
Recoil starter

18
GENEMAX 7000 IS GENEMAX 7000 IS
(18) Current run time
18
13
12
11 12 13 14
8 9 10
(8) (Normal operation)
(9) Bluetooth logo (10) Fuel quantity
(11) AC Voltage (12) AC Voltage
(13)AC Current (14) AC Current
Operation identification
15 16 17
(15) Power (16) Speed (17) Frequency
(1)
(2) QR Code for Bluetooth Connection
3 4
(5) Overload indicator light (6) AC pilot light
(7) Operating key
Multimeter
( ) Liquid crystal display ( ) Oil warning light
1 2 3 4 5 6 7
Inverter Generator
Owner's Manual
Control Function
Inverter Generator
Owner's Manual
Control Function
Esc throttle
Turb
ESC
THROTTLE
ON
OFF
“ON”
When the ESC switch is turned to
“ON”, the economy control unit
controls the engine speed according to
the connected load. The results are
better fuel consumption and less
noise.
“OFF”
When the energy saving switch is
placed on the “Off” position, under the
condition of load less than 4.5kW, the
engine runs at the rated speed
(3,100r/min).
“TURB”
When the energy saving switch is
placed on the position of “TURB”, the
engine runs at the rated speed
(3,600r/min) regardless of whether the
load is connected or not.
Tip: When the following devices are
applied, such as air compressor and
submersible pump, ESC must be turned
off and the energy saving switch must be
placed on the position of “TURB”.
Digital display meter
1. When the combination switch is placed
on the “Off” position (when the engine is
not started):
Operate key 7, only the content of 19 is
displayed on the screen interface (after
each operation of key 7, the display will
disappear automatically after maintaining
5s.).
2. When the engine is not started, but the
combination switch is on the “On” position:
a. No content is displayed on the screen
interface.
Notes: If the battery has been installed,
this interface indicates that the battery
voltage is less than 8V (the battery needs
to be charged), one-key start and Blue
tooth APP start cannot be carried out, but
the engine can be started by recoil starter.
If there is no display after replacing the
battery with new one, please contact the
designated dealer.
b. The screen interface displays the
contents of 21-22 and 23 (2 display
interfaces in total).
Notes: The interface with the display
contents of 21-22 indicates that the
battery voltage is more than 10V, one-key
start and Blue tooth APP start can be
carried out.
c. The screen interface displays the
contents of 24-26 and 23 (2 display
interfaces in total).
Notes: The interface with the display
content of 24-26 indicates that the battery
voltage is more than 8V but less than 10V,
one-key start and Blue tooth APP start
cannot be carried out, but the engine can
be started by recoil starter.
Prompt: The interface with the display
content of 23 can be used for connecting
the Mac address of Blue tooth device.
The display interface can be switched by
operation of key 7, and the contents are
displayed in turn.
When the above contents are displayed in
each display interface, the contents of 27,
9 (displayed with Blue tooth, not displayed
without Bluetooth) and 10 are also
displayed at the same time.
(19) Cumulative running time
19
Digital display meter

19
GENEMAX 7000 IS GENEMAX 7000 IS
(18) Current run time
18
13
12
11 12 13 14
8 9 10
(8) (Normal operation)
(9) Bluetooth logo (10) Fuel quantity
(11) AC Voltage (12) AC Voltage
(13)AC Current (14) AC Current
Operation identification
15 16 17
(15) Power (16) Speed (17) Frequency
(1)
(2) QR Code for Bluetooth Connection
3 4
(5) Overload indicator light (6) AC pilot light
(7) Operating key
Multimeter
( ) Liquid crystal display ( ) Oil warning light
1 2 3 4 5 6 7
Inverter Generator
Owner's Manual
Control Function
Inverter Generator
Owner's Manual
Control Function
Esc throttle
Turb
ESC
THROTTLE
ON
OFF
“ON”
When the ESC switch is turned to
“ON”, the economy control unit
controls the engine speed according to
the connected load. The results are
better fuel consumption and less
noise.
“OFF”
When the energy saving switch is
placed on the “Off” position, under the
condition of load less than 4.5kW, the
engine runs at the rated speed
(3,100r/min).
“TURB”
When the energy saving switch is
placed on the position of “TURB”, the
engine runs at the rated speed
(3,600r/min) regardless of whether the
load is connected or not.
Tip: When the following devices are
applied, such as air compressor and
submersible pump, ESC must be turned
off and the energy saving switch must be
placed on the position of “TURB”.
Digital display meter
1. When the combination switch is placed
on the “Off” position (when the engine is
not started):
Operate key 7, only the content of 19 is
displayed on the screen interface (after
each operation of key 7, the display will
disappear automatically after maintaining
5s.).
2. When the engine is not started, but the
combination switch is on the “On” position:
a. No content is displayed on the screen
interface.
Notes: If the battery has been installed,
this interface indicates that the battery
voltage is less than 8V (the battery needs
to be charged), one-key start and Blue
tooth APP start cannot be carried out, but
the engine can be started by recoil starter.
If there is no display after replacing the
battery with new one, please contact the
designated dealer.
b. The screen interface displays the
contents of 21-22 and 23 (2 display
interfaces in total).
Notes: The interface with the display
contents of 21-22 indicates that the
battery voltage is more than 10V, one-key
start and Blue tooth APP start can be
carried out.
c. The screen interface displays the
contents of 24-26 and 23 (2 display
interfaces in total).
Notes: The interface with the display
content of 24-26 indicates that the battery
voltage is more than 8V but less than 10V,
one-key start and Blue tooth APP start
cannot be carried out, but the engine can
be started by recoil starter.
Prompt: The interface with the display
content of 23 can be used for connecting
the Mac address of Blue tooth device.
The display interface can be switched by
operation of key 7, and the contents are
displayed in turn.
When the above contents are displayed in
each display interface, the contents of 27,
9 (displayed with Blue tooth, not displayed
without Bluetooth) and 10 are also
displayed at the same time.
(19) Cumulative running time
19
Digital display meter

20
GENEMAX 7000 IS GENEMAX 7000 IS
1514
(20) Remaining run time
(21)
(22) Battery(Voltage greater than 10V)
Battery normal
21 22
20
23
(23) MAC address
26 27
24
25
(24) Operation identification(Not running)
(25) Battery(loss of capacity)
(26) Hand Start Tips
(27) Battery(More than 8V and less than 10V)
Inverter Generator
Owner's Manual
Control Function
Inverter Generator
Owner's Manual
Control Function
(31) Maintenance identification
31
28
(28) Maintenance tips
29 30
(29) Fault identification
(30) Fault code symbol
displayed in each display interface, the
contents of 9 (displayed with Blue tooth,
not displayed without Blue tooth) and 10
are also displayed at the same time.
5. When the combination switch is on the
“On” position, the engine is not started or
the engine is started successfully (running
normally): the screen interface displays
the content of 28, and the content of 28
represents the information as follows:
When the generator set reaches the
maintenance time, it needs to be
maintained immediately. If maintenance
has been carried out, operate key 7 to
clear this information.
Prompt: Operate key 7 to clear the
maintenance information, the screen
automatically switches to the next
interface.
If key 7 is not operated to clear the
maintenance information, the content of 28
will be displayed once every 1 minute in
each screen interface for 10 seconds and
the content of 28 will not be displayed
again until 2 hours later. At the same time,
the maintenance mark will not be
displayed on the right side of the Bluetooth
mark on the screen interface, until the
generator set is maintained and key 7 is
operated to clear the maintenance
information.
If the unit does not have Blue tooth, the
screen interface does not display the
content of 23.
3. When the combination switch is placed
on the “On” position, and the engine starts
successfully and runs normally: the
screen interface displays the contents of
11-14, 15-17, 18, 19, 20, 21-22 and 23 (7
display interfaces in total).
Prompt: The interface content of 23 is
used for the Mac address of connecting
Blue tooth device.
The display interface can be switched by
operation of key 7, and the contents are
displayed in turn.
When the above contents are displayed in
each display interface, the contents of 8, 9
(displayed with Blue tooth, not displayed
without Blue tooth) and 10 are also
displayed at the same time.
If the unit does not have Bluetooth, the
screen interface does not display the
content of 23.
4. When engine runs with failure: the
screen interface displays the contents of
29-30, and the content of 30 represents
the fault information as follows:
U> a: AC over voltage, indicating the
character of AC (alternative
indication of AC and digit)
b: DC over voltage, indicating the
character of DC (alternative
indication of DC and digit)
U< a: AC under-voltage, indicating the
character of AC (alternative
indication of AC and digit)
b: DC under-voltage, indicating the
character of DC (alternative
indication of DC and digit)
I> Output over current of generator.
Output short circuit of generator.
Over heat of frequency converter.
Prompt: When the above contents are
Oil warning light
When the oil level falls below the lower
level, the oil warning light comes on and
then the engine stops automatically.
Unless you refill with oil, the engine will
not start again.
Tip: If the engine stalls or does not start,
turn the engine switch to “ON” and
then pull the recoil starter. If the oil
warning light flickers for a few
seconds, the engine oil is insufficient.
Add oil and restart.
Table of contents
Popular Portable Generator manuals by other brands

Northern Lights
Northern Lights M864W Operator's manual

Nature's Generator
Nature's Generator Elite user manual

Baur
Baur SSG 1100 user manual

Lutz
Lutz Easyzon D 100 Installation, operation & maintenance instructions

Champion Global Power Equipment
Champion Global Power Equipment 200992 quick start guide

Champion Power Equipment
Champion Power Equipment 72531 Owner's manual & operating instructions

Firman
Firman P03501 owner's manual

Chicago Electric
Chicago Electric 92455 operating instructions

Circutor
Circutor SVG instruction manual

Briggs & Stratton
Briggs & Stratton ELITE 030210 owner's manual

Thunder Scientific
Thunder Scientific 9500 Operation and maintenance manual

Porter-Cable
Porter-Cable PCG2200 instruction manual