manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Maytag
  6. •
  7. Dryer
  8. •
  9. Maytag MEDB750YW0 User manual

Maytag MEDB750YW0 User manual

Other Maytag Dryer manuals

Maytag MGD8200FC User manual

Maytag

Maytag MGD8200FC User manual

Maytag MED5900TW0 User manual

Maytag

Maytag MED5900TW0 User manual

Maytag D-2 User manual

Maytag

Maytag D-2 User manual

Maytag W10529646B User manual

Maytag

Maytag W10529646B User manual

Maytag MGDC215EW0 User manual

Maytag

Maytag MGDC215EW0 User manual

Maytag MDE17MN User manual

Maytag

Maytag MDE17MN User manual

Maytag MLG-45 User manual

Maytag

Maytag MLG-45 User manual

Maytag MEDC500VW - Centennial Series 29 Inch Electric... User manual

Maytag

Maytag MEDC500VW - Centennial Series 29 Inch Electric... User manual

Maytag MGDX5SPAW User manual

Maytag

Maytag MGDX5SPAW User manual

Maytag MEDE300V Parts list manual

Maytag

Maytag MEDE300V Parts list manual

Maytag MEDZ600TB User manual

Maytag

Maytag MEDZ600TB User manual

Maytag MGD5600TQ1 User manual

Maytag

Maytag MGD5600TQ1 User manual

Maytag MEDE251YG1 User manual

Maytag

Maytag MEDE251YG1 User manual

Maytag MDE2400AYW - 3.7 cu. Ft. Electric Dryer User manual

Maytag

Maytag MDE2400AYW - 3.7 cu. Ft. Electric Dryer User manual

Maytag 3LMEDC315FW User manual

Maytag

Maytag 3LMEDC315FW User manual

Maytag MGDB400VQ0 User manual

Maytag

Maytag MGDB400VQ0 User manual

Maytag MLG24PDAGW0 User manual

Maytag

Maytag MLG24PDAGW0 User manual

Maytag LD9824 User manual

Maytag

Maytag LD9824 User manual

Maytag MDG22PD User manual

Maytag

Maytag MDG22PD User manual

Maytag MDG28PD User manual

Maytag

Maytag MDG28PD User manual

Maytag YMEDB400VQ0 User manual

Maytag

Maytag YMEDB400VQ0 User manual

Maytag MDG6800AWW User manual

Maytag

Maytag MDG6800AWW User manual

Maytag MDG7400AWQ User manual

Maytag

Maytag MDG7400AWQ User manual

Maytag HYE3657AYW Manual

Maytag

Maytag HYE3657AYW Manual

Popular Dryer manuals by other brands

Whirlpool WED9270XL2 parts list

Whirlpool

Whirlpool WED9270XL2 parts list

Kleenmaid KED2000 Repair instructions

Kleenmaid

Kleenmaid KED2000 Repair instructions

SPI Supplies SPI-DRY Operation manual

SPI Supplies

SPI Supplies SPI-DRY Operation manual

Amana NGD5800DW Use & care guide

Amana

Amana NGD5800DW Use & care guide

Bosch WTG86402GB Installation and operating instructions

Bosch

Bosch WTG86402GB Installation and operating instructions

ffuuss eos user manual

ffuuss

ffuuss eos user manual

KitchenAid 53-3498 installation instructions

KitchenAid

KitchenAid 53-3498 installation instructions

Schulthess Spirit topLine TW 8340 operating instructions

Schulthess

Schulthess Spirit topLine TW 8340 operating instructions

Whirlpool LGR4624BW0 parts list

Whirlpool

Whirlpool LGR4624BW0 parts list

World Dryer AirMax D M5-972A manual

World Dryer

World Dryer AirMax D M5-972A manual

Alliance Laundry Systems ADEE9BSS user guide

Alliance Laundry Systems

Alliance Laundry Systems ADEE9BSS user guide

Miele PDR 910 EL Operating and installation instructions

Miele

Miele PDR 910 EL Operating and installation instructions

Amana NGD5800TQ0 parts list

Amana

Amana NGD5800TQ0 parts list

Bosch WTA79200GB Installation and operating instructions

Bosch

Bosch WTA79200GB Installation and operating instructions

AEG TR838P4OB user manual

AEG

AEG TR838P4OB user manual

Asko T760 user guide

Asko

Asko T760 user guide

Electrolux EW2H328R2 user manual

Electrolux

Electrolux EW2H328R2 user manual

Dawlance Spinner DS 6000 C owner's manual

Dawlance

Dawlance Spinner DS 6000 C owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Electric Dryer Installation Instructions
Table of Contents
DRYER SAFETY ......................................................................... 2
iNSTALLATiON REQUIREMENTS ............................................. 3
Tools and Parts ...................................................................... 3
Location Requirements ......................................................... 4
Electrical Requirements ........................................................ 5
install Leveling Legs .............................................................. 6
Electrical Connection ............................................................ 6
VENTING ................................................................................... 12
Venting Requirements ......................................................... 12
Plan Vent System ................................................................. 13
Install Vent System .............................................................. 14
CONNECT iNLET HOSES ........................................................ 14
CONNECT VENT ...................................................................... 16
LEVEL DRYER .......................................................................... 16
COMPLETE iNSTALLATiON CHECKLIST .............................. 17
REVERSE DOOR SWING ......................................................... 17
TROUBLESHOOTING .............................................................. 19
iNSTALLATiON NOTES
Date of purchase:
Date of installation:
installer:
Model number:
Serial number:
Para obtener acceso al manual de uso y cuidado en espaSol, o para obtener informaci6n adicional acerca de su
producto, visite:
www.whirlpool.com
Tenga listo su nOmero de modelo completo. Puede encontrar el nOmero de modelo y de serie dentro de la cavidad
superior de la puerta.
W10347663A
W10352825A=SP
DRYER S_ETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING -"Risk of Fire"
-Clothes dryer installation must be performed by aqualified installer,
- install the clothes dryer according to the manufacturer's instructions and local codes.
- Do not install aclothes dryer with flexible plastic venting materials, if flexible metal
(foil type) duct is installed, it must be of a specific type identified by the appliance
manufacturer as suitable for use with clothes dryers. Fle×ible venting materials are
known to collapse, be easily crushed, and trap lint. These conditions will obstruct
clothes dryer airflow and increase the risk of fire.
- To reduce the risk of severe injury or death, follow all installation instructions.
- Save these instructions.
2
IN$ LATION REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed:
Flat-blade screwdriver #2 Phillips screwdriver
Parts supplied (all models):
Leveling legs (4)
Parts supplied (steam models):
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
I1®®®1
Level &
"Y" connector Short inlet hose
Wire stripper (direct wire
installations)
Caulking gun and
compound (for installing
new exhaust vent)
Vent clamps
Tin snips (new vent
installations)
5' inlet hose Rubber washer
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed: (Not supplied with dryer)
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhuast system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the "Assistance
or Service" section in your "Use and Care Guide".
Optional Equipment: (Not supplied with dryer)
Refer to your "Use and Care Guide" for information about
accessories available for your dryer.
1/4" nut driver
(recommended) Tape measure
Pliers
Explosion Hazard
Keep flammable materials and vapors, such as
gaso|ine, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[] A location allowing for proper exhaust installation. See
"Venting Requirements."
[] A separate 30 amp circuit.
[] If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer. See
"Electrical Requirements."
[] Floor must support dryer weight of 200 Ibs. (90.7 kg). Also
consider weight of companion appliance.
[] Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
[] For a garage installation, place dryer at least 18" (457 mm)
above floor. If using a pedestal, you will need 18" (457 mm)
to bottom of dryer.
[] Steam models only: Cold water faucets located within 4 ft.
(1.2 m) of the water fill valves, and water pressure of 20-100
psi (137.9-689.6 kPa). You may use the water supply for your
washer using the "Y" connector and short hose (if needed)
which are provided.
For each arrangement, consider allowing more space for ease
of installation and servicing; spacing for companion appliances
and clearances for walls, doors, and floor moldings. Space
must be large enough to allow door to fully open. Add spacing
on all sides of dryer to reduce noise transfer. If a closet door
or Iouvered door is installed, top and bottom air openings
in door are required.
IMPORTANT." Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
45° F (7° C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
iNSTALLATiON CLEARANCES
Location must be large enoughto allow dryer door to open fully.
DRYER DiMENSiONS
Dryer with extended back: Dryer with flat back:
30"
(78sram)f
431/2"
(783 ram}
-,,P-- 22%"----_
(565 ram) .,_--- 28"-----_
w]w-
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See "Venting
Requirements."
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested
spacing of 0" (0 mm) clearance on sides and rear.
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door, and
floor moldings.
[] Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
[] For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
[] Companion appliance spacing should also be considered.
(25ram) (73._=rnm)(25ram)
Recessedarea
_1 ]4" max," e
(25ram) (7a3ram) (127ram)
Side view - closet or confined area
(Dryerwith extended back)
28" (127ram}
(25ram) (711ram)
Side view - closet or confined area
(Dryer with flat back)
48"_*--[_
(310cm2)I
+
(76ram}
Closet door with vents
* Requiredspacing
4
Mobilehome =Additional installation requirements:
This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard
for Mobile home construction
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240
MH.
Mobile home installations require:
[] Metal exhaust system hardware, available for purchase from
your dealer. For further information, see "Assistance or
Service" section in your "Use and Care Guide".
[] Special provisions must be made in mobile homes to introduce
outside air into dryer. Openings (such as a nearby window)
should be at least twice as large as dryer exhaust opening.
ELECTRIC, REQUIREMENWS
it is your responsibility:
[] To contact a qualified electrical installer.
[] To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70
- latest edition and all local codes and ordinances.
[]
[]
[]
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240
volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208
volt electrical supply, if specified on the serial/rating plate)
on a separate 30-amp circuit, fused on both sides of the line.
Connect to an individual branch circuit. Do not have a fuse in
the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
[]
[]
[]
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor
is permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection, the neutral ground conductor must be
removed from the external ground connector (green screw),
and secured under the neutral terminal (center or white wire)
of the terminal block. When the neutral ground conductor
is secured under the neutral terminal (center or white wire)
of the terminal block, the dryer cabinet is isolated from
the neutral conductor.
If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see "Optional 3-wire
connection" section.
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes prohibit grounding through the neutral
conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
[] A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to
the dryer must end in ring terminals or spade terminals
with upturned ends.
[] A UL listed strain relief.
if your outlet looks like this:
4-wire
receptacle
(14-30R)
Then choose a 4-wire power supply cord with
ring or spade terminals and UL listed strain
relief. The 4-wire power supply cord, at least
4 ft. (1.22 m) long, must have 4 10-gauge solid
copper wires and match a 4-wire receptacle of
NEMA Type 14-30 R. The ground wire (ground
conductor) may be either green or bare. The
neutral conductor must be identified by a
white cover.
if your outlet looks like this:
Then choose a 3-wire power supply cord with
ring or spade terminals and UL listed strain
relief. The 3-wire power supply cord, at least
4 ft. (1.22 m) long, must have 3 10-gauge solid
copper wires and match a 3-wire receptacle of
NEMA Type 10-30R.
3-wire
receptacle
(10-30R)
if connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
[] Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with flexible metallic conduit. All
current-carrying wires must be insulated.
[] 10-gauge solid copper wire (do not use aluminum) at least
5 ft. (1.52 m) long.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
INSTALL LE¥_LING LEGS
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1, Prepare dryer for leveling legs
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
Screw in leveling legs
diamond
marking
Examine leveling legs, find diamond marking. Screw legs into
leg holes by hand, use a wrench to finish turning legs until
diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its final location. Leave enough room for electrical
connection and to connect the exhaust vent.
ELEC%RIC_ CONNECTION
Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use aUL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Electrical Connection Options
1, Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to Power Supply Cord Connection.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to Power Supply Cord Connection.
4-wire direct connection:
Go to Direct Wire Connection.
3-wire direct connection:
Go to Direct Wire Connection.
NOTE: If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to "Optional
3-wire connection." This connection may be used with
either a power supply cord or a direct wire connection.
6
B E C
Before you start, disconnect power. Remove hold-down
screw (D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down screw
E. Neutral ground wire
EHole below terminal block cover
POWER SUPPLY CORD
CONNECTION
Power supply cord strain relief
Attach power supply cord
strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening
(B) so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
Attach power supply cord
to strain relief
If your outlet looks like this:
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to "4-Wire Power Supply Cord
Connection" on this page.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to "3-Wire Power Supply Cord
Connection" on page 8.
4=WIRE POWER SUPPLY CORD CONNECTION
IMPORTANT: A 4-wire connection isrequiredfor mobile homes and
where localcodes do not permit the useof 3-wire connections.
4-wire receptacle (NEMA
type 14-30R)
Spade terminals with
upturned ends
4-prong plug
Ring terminals
, Prepare to connect neutral
ground wire and neutral wire
Remove center terminal block screw (B). Remove neutral
ground wire (E)from external ground conductor screw (A).
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
Connect neutral ground wire
and neutral wire
Connect neutral ground wire (E) and neutral wire (white) (C)
of power supply cord under center terminal block screw (B).
Tighten screw.
Connect ground wire
3=WIRE POWER SUPPLY CORD CONNECTION
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
3-wire receptacle (NEMA
type 10-30R) 3-prong plug
Spade terminals with
upturned ends Ring terminals
Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.
Remove center terminal block screw (B).
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Venting Requirements". Connect neutral wire (white or center) (C) of power supply cord
to center terminal block screw (B). Tighten screw.
8
3. connectremaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Venting Requirements".
Direct Wire
Fire Hazard
Use 10 gauge copper wire.
Use aUL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
DIRECT WIRE CONNECTION
Direct wire strain relief
["1, Attach direct wire strain relief
to strain relief
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in
a horizontal position. Tighten strain relief screw against the
direct wire cable.
if your wiring looks like this:
4-wire direct connection:
Go to "4-Wire Direct Connection"
on this page.
3-wire direct connection:
Go to "3-Wire Direct Connection"
on page 10.
4=WIRE DIRECT WiRE CONNECTION
iMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit 3-wire connections.
1, Prepare your 4=wire cable for
direct connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 11/2"(38 mm)
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads.
ground wire and neutral wire 5, Connect remaining wires
Remove center terminal block screw (B). Remove neutral
ground wire (E)from external ground conductor screw (A).
and neutral wire
Connect neutral ground wire (E) and place
hooked end (hook facing right) of neutral
wire (white or center wire) (C) of direct wire
cable under center screw of terminal block
(B). Squeeze hooked ends together and
tighten screw.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
"Venting Requirements".
3=WIRE DIRECT WiRE CONNECTION
Use where local codes permit connecting cabinet=ground
conductor to neutral wire.
1, Prepare your 3-wire cable for
direct connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 31/2" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
Remove center terminal block screw (B).
10