Component and Oven Testing Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
May 2005 3 16026294
©2005 Maytag Services
Illustration Component Test Procedure Results
Bake element Disconnect wiring to element and
measure cold resistance of terminals. .......
Measure voltage at bake element ..............
Approx. 22 Ω.
240 VAC.
Hi-limit temperature
switch
Normally closed, verify operation:
Open: 208° to 222°F (98° to 105°C) .........
Closed: 156° to 174°F (69° to 79°C).........
Infinite.
Continuity.
Cooling fan motor Measure voltage ........................................
Check motor windings to ground................
120 VAC.
No continuity.
RPM: 1670 to 2070
Oven Control Testing Procedures
Illustration Component Test Procedure Results
M1 Controlled Oven temperature
adjustment
Press
Bake
pad.
Enter
550
on the digit-pad.
Immediately press and hold
Bake
pad
for 3 to 5 seconds.
Oven can be adjusted from -35 to +35
degrees in 5-degree increments by
pressing
(slew up)
or
(slew down)
pads. To avoid over adjusting the
oven, move temperature 5 degrees
each time. Wait 4 seconds for the data
entry timer to expire to accept the
change. Temperature adjustment will
be retained even through a power
failure.
While increasing or decreasing oven
temperature, this does not affect self-
cleaning temperature.
M1 Controlled Temperature display Press and hold
Cancel
and
Bake
pads for 3 to 5 seconds. Press
(slew up)
or
(slew down)
pads to
change.
This mode enables the user to indicate
°F or °C on the display.
M1 Controlled Clock Display Press and hold
Cancel
and
Clock
pads for 3 to 5 seconds.
Allows clock to be toggled On or OFF.
M1 Controlled 24 Hour Clock Press and hold
Cancel
and
Delay
pads for 3 to 5 seconds. Press
(slew up)
or
(slew down)
pads to
change.
Allows the time on the clock to be
toggled from 12 hour or 24 hour display.
M1 Controlled Factory Default Press and hold
Cancel
and
Keep
Warm
pads for 3 to 5 seconds until
beep sounds.
Allows the clock to be reset to factory
settings.
M1 Controlled Twelve hour off Control will automatically cancel any
cooking operation and remove all relay
drives 12 hours after the last pad
touch.
See Sabbath mode to disable.
M1 Controlled Sabbath Mode Hold
Clock
pad for 3 to 5 seconds to
activate Sabbath mode.
Hold
Clock
for 3 to 5 seconds to
disable Sabbath mode.
Desired bake function must be
initiated before entering Sabbath
mode.
"SAb" will be displayed and flash for 5
seconds then remain on until timed-out
or cancelled.
The status "SAB" is NOT fault code 5A6.
All pad inputs are disabled except for
CANCEL and CLOCK pads.
This mode disables the normal 12 hour
shutoff to allow operation of the bake
mode for a maximum of 72 hours.
The oven light is not disabled.