manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. mbj
  6. •
  7. Light Fixture
  8. •
  9. mbj SRL-12 User manual

mbj SRL-12 User manual

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Cooper Lighting Halo L10538 specification

Cooper Lighting

Cooper Lighting Halo L10538 specification

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

Philips 32614 Series user manual

Philips

Philips 32614 Series user manual

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Lightolier LP200 specification

Lightolier

Lightolier LP200 specification

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Cooper Lighting Halo L3232E Specification sheet

Cooper Lighting

Cooper Lighting Halo L3232E Specification sheet

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier Lytespan 83ED17S specification

Lightolier

Lightolier Lytespan 83ED17S specification

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Segmented Ringlight
Operating Manual
Technical Data
Model Sizes in Series
The light is available in the following size 1)
SRL-12
1) Size definition refers to the outer luminous area diameter in cm.
Possible LED Colors (Color mix for segments on request)
LED Abbr.1) Peak Wavelength2)
White -WT 5000 K, CRI80
Red -RD near 625 nm
Green -GN near 470 nm
Blue -BE near 521 nm
Infrared -IR near 850 nm
1) Color option will be added to the model name aer the size information.
SRL-12-4WT refers to a ringlight with 4 segments with white LED light.
2) This is an approximated value. The exact value also depends on LED temperature
and LED current
MBJ Imaging GmbH
Jochim-Klindt-Straße 7 +49 4102 778 90 - 31
22926 Ahrensburg, Germany [email protected]
www.mbj-imaging.com
Mechanical Integration
The lights are equipped with 4 combined mounting positions of thread-
ed or through holes. It can be used to fix the lighting to the specified
position. To secure a long live time additional heat transfer measure-
ments at the holding positions are highly recommended.
03412.00 Manual MBJ Segmented Ringlight, Februar 2023
Safety Notes
Before working with this unit, read the warning and application instruc-
tions carefully and completely before operating the device.
Have the illuminators commissioned only in compliance with the
specified protective measures. It is essential that you comply with the
permissible ambient conditions. The lighting must be switched o before
installation and/or maintenance. The device must not be used when a
failure may cause personal injury.
1. The device is designed for indoor use only.
2. Light – Due to the risk of irritation of or damage to the eyes or
skin it is not recommended to look directly into the light source.
3. Heat –In case of insufficient heat dissipation or when running the
light in flash mode with a too high duty cycle, the surface tempera-
ture may get hot. Do not touch the product during operation or
immediately after it is turned off. Keep off flammable materials at
any time and allow for sufficient heat dissipation.
4. Electricity – The housing is electrically isolated from the ground
of the power supply. Operate only with the permissible current.
Exceeding the permissible current can lead to the destruction of
the device or to a significant shortening of the lifetime of the LEDs
in the device.
5. Usage – Please prevent mechanical stress to the light surface during
operation. This will lead to an inhomogeneous light emission.
6. Cleaning – The light emission surface has to be cleaned with a
standard glass cleaner and a soft cleaning cloth. Do not use other
material for cleaning as it will damage the device.
Model SRL-12
More 2D and 3D drawings can be found online:
www.mbj-imaging.com
Specification Segmented Ringlight
Operating temperature 10°C to 30°C / 45°C1)
Certifications CE, RoHS
Degree of protection IP54 or IP672)
Humidity 30 % to 70 %
1) Max. of 30°C is recommended for steady light operation w/o additional heat
transfer measurements, for max. 45°C a thermal connection is mandatory. Max.
of 45°C is also permissible for flash light operation with a max. 10% duty cycle.
2) MBJ LED lights are protected against the ingress of solids and water in accor-
dance with the selected protection class and applicable standards. Permanent
protection against liquids containing solvents, such as cleaning agents, machine
emulsions or other lubricants, cannot be guaranteed. IP is only valid with a
connected cable (MBJ cable recommended).
Optional:
Specification Segmented SRL-12 / Segmented SRL-12-IP
Optical parameter
Luminous area (ID-OD) 87 mm - 121 mm
Light emission Ring shaped light field with direct light emission, 6 power LED with 80° beam, 6 LED/segment
Recommended use Commonly used for shape from shading applications & highlighting dierent optical surface structures.
Recommended light working distance 75 mm - 200 mm
Luminous Flux of white LEDs1) 2260 lm
Radiant Power of red LEDs [mW] 1) 780 mW (4 sgements)
Radiant Power of IR LEDs [mW] 1) 3750 mW
Electrical parameter
Available interfaces -x with direct LED access (external 4-channel LED control is required)
ULed(+) range for -x version2) WT: 17 … 20 VDC; RD: 12 … 15 VDC; IR: 9 … 12 VDC
4 segment operation 1 segment operation
Typical Power steady light 15 W (3,75 W / channel) 9 W
Recommended LED current
Steady light (100% duty cycle) 900 mA (total max. for all segments) 450 mA (max. for one segment)
Flash light (50 % duty cycle, < 500 ms pulse) 1800 mA(total max. for all segments) 900 mA(max. for one segment)
Flash light (25 % duty cycle, < 50 ms pulse) 2700 mA(total max. for all segments) 1350 mA(max. for one segment)
Flash light (10 % duty cycle, < 5 ms pulse) 3600 mA(total max. for all segments) 1800 mA(max. for one segment)
General parameter
Dimension (H x W x D) 130 mm x 141 mm x 14 mm
Lens hole diameter [Ø]80 mm
Weight 300 g
Material Anodized aluminum housing with PMMA light cover
Connector M12x1 socket, 8 pin, male (for pinning details refer to chart “Electrical Connection”)
Accessories For cable, mounts and LED controller please check www.mbj-imaging.com
1) Values are approximate with a +/- 7 % tolerance.
2) Lower voltage value refers to steady light, higher voltage value refers to flash light, please see max. allowed current in the rows below.
Electrical Connection
The lighting is equipped with an 8 pin M12x1 connector.
Pin Color 1) SRL-12 4 Segments2)
1 white Segment 1 LED (+)
2 brown Segment 1 LED (-)
3 green Segment 2 LED (+)
4 yellow Segment 2 LED (-)
5grey Segment 3 LED (+)
6 pink Segment 3 LED (-)
7 blue Segment 4 LED (+)
8red Segment 4 LED (-)
1) Wire color of MBJ lighting cable
2) Connection to 24VDC without external LED controller may destroy the unit
Additional information
For connection it is recommended to use the MBJ light cable M12/8P with a
maximum length of 5 m and CTR-52 4-channel controller.
1
2
3
4
Segment 1
Segment 2
Segment 3
Segment 4
More information and tips
Please scan the QR-Code to visit our Website
for more product information.
i
Shape from shading example Radiation Characteristics
1
3
2
4
5
8
7
6