MDV IMPACT MONO AHPM V4W/D2N8-B Dimension Guide

E
nginee
r
i
ng D
ata
ATW HEAT PUMP
IMPACT
MONO 4-16 kW

1
CONTENTS
Part 1 General Information ............................................................................ 3
Part 2 Engineering Data ............................................................................... 17
Part 3 Installation and Field Settings .......................................................... 61
IMPACT MONO Type

IMPACT MONO type
2

3
-
...............................................................................
...........................................................................................
............................................................................................
..............................................................
...................................................................................
IMPACT Split System
IMPACT MONO Type

4
1.1
-
-
-
-
IMPACT
1 Impact Mono System
IMPACT MONO type
IMPACT

5
-
1.2
-
-
-
-
The IMPACT Mono can be configured to run
IMPACT MONO Type

6
2
-
- - - - -
-
-
-
-
-
1.
- - - -
3
-
- -
- -
-
Impact
(AHPM-)
AMHP
Aircon
ER90 E: Electric heater
R: 3-phase
90: 9 kW
IMPACT MONO type

7
-
4
4.1
-
1.
2.
Please select the IMPACT Mono unit capacity based on
IMPACT
IMPACT
Impact
IMPACT MONO Type

8
4.2
4.3
4.4
- - - - - - -
IMPACT
IMPACT MONO type
IMPACT's

9
-
5
5.1
-
-
-
1.
IMPACT MONO Type

10
IMPACT MONO type

11
-
5.2
- -
-
1.
IMPACT MONO Type

12
- -
-
-
1.
IMPACT MONO type

13
-
- -
-
-
1.
IMPACT MONO Type

14
5.3
- -
- -
1.
Modularity is perfect when an extension of capacity becomes required as the building cooling/heating demand evolves. 6
units can be controlled in group. The group control system can control and view the operation of the entire system only by
connecting the master to the wire controller. If the DHW function is required, the water tank can only be connected to the
master unit water circuit through a three-way valve, and controlled by the master unit. If AHS is needed, it can only be
connected to the master waterway and controlled by the master unit. The Tbt1 temperature sensor must be installed in
the parallel system (otherwise unit cannot be started). If the balance tank is too large, Tbt2 needs to be added in order to
improve the control accuracy. Tbt2 is set in the lower part of the balance tank. The water inlet and outlet pipe joints of
each unit of the parallel system should be connected with soft connections and one-way valves must be installed at the
IMPACT MONO type

15
-
water outlet pipe.
IMPACT MONO Type

16
IMPACT MONO type

17
Part 2
Engineering Data
1 Specifications ........................................................................................... 18
2 Dimensions and Center of Gravity ............................................................ 24
3 Piping Diagrams ....................................................................................... 26
4 Wiring Diagrams ....................................................................................... 28
5 Capacity Tables......................................................................................... 37
6 Operating Limits ....................................................................................... 51
7 Hydronic Performance .............................................................................. 52
8 Sound Levels ............................................................................................ 53
9 Accessories .............................................................................................. 59
IMPACT MONO Type

18
1 Specifications
Outdoor unit model name
220-240/1/50V/Ph/HzPower supply
Heating A7W35
10.08.406.354.20kWCapacity
2.021.631.280.82kWRated input
4.955.154.955.10COP
Heating A7W45
10.08.106.304.30kWCapacity
2.672.101.701.13kWRated input
3.85 3.753.703.80COP
Heating A7W55
9.507.506.004.40kWCapacity
3.062.362.031.49kWRated input
3.103.182.952.95COP
Heating A-7W35
8.007.006.004.70kWCapacity
2.622.192.001.52kWRated input
3.20 3.053.003.10COP
Heating A-7W55
6.15 6.855.154.00kWCapacity
3.433.002.582.05kWRated input
2.002.052.001.95COP
Cooling A35W18
9.908.306.504.50kWCapacity
2.181.641.350.82kWRated input
4.555.054.805.50EER
Cooling A35W7
8.207.457.004.70kWCapacity
2.522.222.331.36kWRated input
3.35 3.253.003.45EER
Seasonal space heating
energy efficiency class
Water outlet at 35 A+++C
Water outlet at 55 A++C
SCOP
Warmer climate 35 C7.096.996.576.46
55 C 4.624.514.214.15
Average climate 35 C5.224.954.85 5.20
55 C 3.373.523.31 3.47
Colder climate 35 C4.334.214.06 4.32
55 C 2.882.852.63 2.99
Sound power Level2595855dB 60
mRated water flow 31.441.09/h 0.72 1.72
mWater flow range 30.4~2.10.4~1.650.4~1.250.4~0.9/h
3.23.23.23.2LInternal water volume
Twin rotaryTypeCompressor
DC fan / 1DC fan / 1Motor type / Number of fansOutdoor fan
Finned tubeAir side heat exchanger
R32 1.4kgRefrigerant
Unit dimension (W H mmD)
Packing dimension (W H 1375mmD)
kgNet/Gross weight
Outdoor air
temperature range
Cooling -5C 43
Heating -25C 35
1295
718
429
885
475
86/107
1465
1035
560
105/132
1385
865
526
AHPM-V4W/D2N8-B***
AHPM-V6W/D2N8-B***
AHPM-V8W/D2N8-B *** AHPM-V10W/D2N8-B***
IMPACT MONO type

19
DHW C -25 43
Water side heat exchanger Plate type
Water side connection R1 " R1 " R5/4" R5/4"
Water setting
temperature range
Cooling C 5 25
Heating C 25 65
DHW3C 30 60
Notes:
1. Relevant EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811/2013; (EU) No 813/2013; OJ 2014/C 207/02.
2. Sound power test condition EN12102-1
3. Maximum domestic hot water temperature 60 is only available with TBH support.
IMPACT MONO Type
This manual suits for next models
9
Table of contents
Popular Heat Pump manuals by other brands

Dimplex
Dimplex SI 22TU Installation and operating instruction

Steinbach
Steinbach BP-50HS-A1 user manual

Carrier
Carrier Aquazone 50RWS036-360 Installation, Start-Up and Service Instructions

AERMEC
AERMEC NRP 0240 Technical manual

Pentair
Pentair ThermalFlo Heat Pump Contol Panel Addendum Addendum manual

TECO
TECO TK 5K instruction manual

Nibe
Nibe CLIMATEMASTER TRANQUILITY 16 Series Installation operation & maintenance

flamco
flamco VHW 260 Installation and user manual

Interline
Interline 59695325 instruction manual

Energie
Energie INVERTER 4/12 Installation and instruction manual

MAXA
MAXA HMV-A 0251 Technical manual

Lennox
Lennox TPA036H4N4 installation instructions