Mechan SCU-1 User manual

Keep this guide for future reference
Description
Operation
Applications
Declaration of Conformity
This information is designed to help suitably qualied
personnel install and operate Mechan Safety equipment.
Before using this product, read this guide thoroughly along
with any relevant European and/or National standards e.g.
Machinery Directive 2006/42/EC and it’s amendments,
Provision and Use of Work Equipment Regulations.
Further information can be obtained from Mechan Controls
Mechan HE safety switches are magnetically coded, solid
state non-contact safety switches for use in machine guard-
ing applications.
Non-contact operation makes the HE switches easy to
install and tolerant to misalignment. The solid state design
is even more tolerant to shock and vibration, and provides
single point switching which makes for a simpler and more
reliable machine guard interlock.
The additional security of the coded magnetic operation
along with fully sealed IP67 rating make these switches
ideal for use in wet or dusty and harsh environments.
The HE safety switches have been designed to connect to
the SCU-1 Safety Control Unit. When installed correctly, up
to 30 switches can be installed in series.
The HE safety switch has 2 x N/O + 1 N/C bi-directional
solid state outputs along with built in LED(s) for indication.
When installed on a machine guard, power is applied, and
the switch and actuator are within the specied operating
range, the N/O Outputs will be closed, the N/C Output will
be open. When the actuator moves out of the operating
range, the N/O Outputs will open, the N/C Output will close.
(See page 3 for LED Indication.)
The HE safety switch and actuator have an 7mm switching
distance and can approach each other from most angles.
When the switch is closed the targets on the printed face of
the switch must be aligned.
To avoid physical damage, do not use the switch and ac-
tuator as a stop, leave a 1-2 mm gap for best operation and
tolerance to machine guard vibration.
Interlocked guards where additional security required.
Door locking is not required.
Harsh environments where vibration, water or dust are
problems.
Food and Beverage packing/lling systems
Dairy Pharmaceutical Paper Industry
Can Forming and Filling, (Aluminium, Steel, Plastic)
Semi conductor Manufacture/Assembly.
APPROVALS
CE Complies with all relevant sections of the
CE marking directive
TUV CAT 4 SIL 3 PLe
EUROPEAN DIRECTIVES
Machinery Directive 2006/42/EC
Low Voltage Directive 2006/95/EC
Electromagnetic Compatibility Directive 2004/108/EC
EUROPEAN STANDARDS
EN ISO
13849-1
Safety of Machinery
Safety related parts of control systems
EN ISO
62061
Safety of Machinery - Functional safety
of safety related electrical, electronic and
programmable electronic control systems
EN 60204 Safety of Machinery
Electrical equipment for machines
EN
60947-5-1
Low voltage switch gear and control gear
EN 1088 Interlocking devices associated with
guards
EN
60947-5-3
Safety of Machinery
Specication for low voltage switchgear
and control gear
See back page for declaration of conformity.
CAT 4
SIL 3 PLe
MECHAN
Installation Guide : SCU-1 & HE Safety Switches
Norstat, Inc. • 300 Roundhill Drive, Unit 4, Rockaway, NJ 07866
Telephone – (973) 586-2500 FAX – (973) 586-1590
E-Mail – [email protected] Website – www.norstat.com

SAFETY CONTROL UNIT
SAFETY SWITCHES
Mounting on 35mm DIN Rail
Mounting the Safety Switches
Removal from 35mm DIN Rail
Indication
CONTROL UNIT RESET
POWER
When power is
connected, the red
LED will be
illuminated
OUTPUT
When K1 & K2 are
illuminated green,
the outputs 13/14
& 23/24 will be
closed and 31/32
will open.
Internal switch is set to the
LOWER position
Circuit X1/X2 requires a
momentary N/O button to
initialise reset.
Internal switch is set to the
UPPER position
Circuit X1/X2 requires a link.
NOTE: Closed contacts on
K3 & K4 can still be moni-
tored
To remove lid, use small screwdriver in the lid recess as
shown and prise gently upwards.
Manual Reset
Automatic Reset
1
2
1
2
The control modules are de-
signed to be mounted in an IP55
(minimum) control cabinet.
The modules clip on to standard
35 mm symmetric DIN-Rail
To remove the modules, gently
lever out the DIN clip with a
small screwdriver as shown (1).
Tilt the unit in the direction (2)
and slip the unit off the DIN Rail
Minimum separation 50mm
between adjacent switches.
Do not use
safety switches
as a stop.
1 mm separation
when closed
provides the best
results.
DO NOT mount
on hinged side of
the guard.
EN1088 :
Hide the actuator where
possible.
50
mm
Minimum Gap
AA
A
SS
S
AS
A
S
Norstat, Inc. • 300 Roundhill Drive, Unit 4, Rockaway, NJ 07866
Telephone – (973) 586-2500 FAX – (973) 586-1590
E-Mail – [email protected] Website – www.norstat.com

SAFETY SWITCHES
Operation
Switching Characteristics
Indication
The HE Safety
switches are ex-
tremely versatile
and can approach
each other from any
angle without false
tripping.
When the guard is
closed the targets
on the printed face
of the switch and
actuator must be
aligned.
HE1 HE1-SS, HE2 & HE2-SS HED
HE1 HE2 HED
GS1 Power Run GS2
Power Off Off Off Off Off Off Off
Power On Gate(s) Open Red Red Off Red Off Off
Power On Gate Closed Green Green Yellow Red Off Off
Power On Gate 1 and 2 Closed Yellow Red Green Yellow
The chart shows the
switching points in
millimetres.
Norstat, Inc. • 300 Roundhill Drive, Unit 4, Rockaway, NJ 07866
Telephone – (973) 586-2500 FAX – (973) 586-1590
E-Mail – [email protected] Website – www.norstat.com

CONNECTIONS & FUSES
Pre-wired Switches
CONTACT OPERATION -The N/O contact(s) on Mechan safety switches are open when the actuator is away from
the switch. When the actuator is within the specied operating distance the N/O contact(s) will close and the N/C
contact will open
FUSES - All contacts should have external fuses tted. Fuse Rating = 400mA Quick Blow
CONNECTION FOR A SINGLE SWITCH
M12 Leaded Quick Disconnect (LQD)
HE1 / HE2 / HED Contacts 2NO + 1 NC
HE1 / HE2
Contacts 1NO + 1 NC
HE1 / HE2 / HED
Contacts 2NO + 1 NC
HE1 / HE2
Contacts 2NO
M12 Leaded Quick Disconnect
Norstat, Inc. • 300 Roundhill Drive, Unit 4, Rockaway, NJ 07866
Telephone – (973) 586-2500 FAX – (973) 586-1590
E-Mail – [email protected] Website – www.norstat.com

CONNECTION FOR UP TO 30 SWITCHES
Norstat, Inc. • 300 Roundhill Drive, Unit 4, Rockaway, NJ 07866
Telephone – (973) 586-2500 FAX – (973) 586-1590
E-Mail – [email protected] Website – www.norstat.com

DIMENSIONS
Control Unit
Safety Switches
HE-1 HE-1-SS
HE-2 HE-2-SS
HE-D
NOTE
HED switch has three options for
cable exit to enusure easy installation:
HED-21-DC-xxC
Cabel exit in centre of switch (1)
HED-21-DC-xxL
Cabel exit from left had sideof the switch (2)
HED-21-DC-xxR
Cabel exit from right hand side of the switch (3)
xx= cable length or lqd
(1)
(3)(2)
Norstat, Inc. • 300 Roundhill Drive, Unit 4, Rockaway, NJ 07866
Telephone – (973) 586-2500 FAX – (973) 586-1590
E-Mail – [email protected] Website – www.norstat.com

SAFETY CONTROL UNIT
Supply nominal voltage 24Vac/dc (+/- 15 %)
Nominal power consumption 3VA
Safety contacts 2 x NO
Auxiliary contact 1 x NC
Output contact rating (max) 4A/230Vac; 2A/24Vdc(Res.)@Cos=1
Output contact rating (min) 10V/10mA
Output contact fuse rating AC=5A; DC=2.5A; Quick blow
Drop out time Deactivation by inputs, 13ms
Internal fuse 100mA Resetable
Internal fuse recovery time >2 Seconds
Internal switches Reset Manual / Automatic—Selectable
Max conductor size 1 x 2.5mm stranded with sleeves, 1 x 4mm solid
Installation group (Control unit) C in accordance with VDE0110
Enclosure protection Housing IP40, Terminals IP20
Operating temperature -10C to +55C (85% Humidity max)
Storage temperature -20C to +60C
Housing material Polycarbonate Red
Mounting / Fixing 35mm Symmetric DIN Rail
Utilisation category in accordance with EN 60947-4-1
Safety contacts:AC1 at 230 V Imin:10mA.Imax:4A
Safety contacts:DC1 at 24 V Imin:10mA.Imax:2A
Air gap creepage in accordance with EN 60947-1 Vibration In Accordance With EN 60068-2-6
Pollution Degree 2 Weight 210g
Overvoltage Category III Frequency 10-55Hz
Rated Insulation Voltage 250V Amplitude 0.35mm
Rated Impulse Withstand Voltage 4.0KV
Simultaneity Channel 1 ∞
Simultaneity Channel 2 ∞
SAFETY SWITCHES
Operation Coded Non-contact
Contact Arrangements 2 x N/O + 1 x N/C
Safety Contact Operating Distance 7mm ON / 12mm OFF
Safety Contact Rating DC: 24Vdc / 400mA
Auxilliary Contact Rating DC: 24Vdc / 400mA
External Fusing ( When not using SCU-1 ) 400mA
Dimensions See page 6
IP Rating IP67
Cable Length 100 Metres max
Operating temperature -10 to +55C
Storeage temperature -20 to +60C
Mounting Target to target
Construction Red ABS Resin Filled or 316 Grade Stainless Steel resin Filled
SAFETY RELATED DATA
PL In accordance with EN ISO 13849-1 PL-e, CAT 4
SIL CL in accordance with EN IEC 62061 SIL 3
PFHd in accordance with EN IEC 62061 3.62 x 10-09
PFH 4.43 x 10-09
B10d 2 X 106
MTTFd >100 years ( Based on usage rate of 360 days/year, 24 hours/day, 10 operations/hour )
Tm(mission time) 20 years
DC 96.5%
SFF 98.2%
TECHNICAL SPECIFICATIONS
Norstat, Inc. • 300 Roundhill Drive, Unit 4, Rockaway, NJ 07866
Telephone – (973) 586-2500 FAX – (973) 586-1590
E-Mail – [email protected] Website – www.norstat.com

Document Number : 340-400-IDv1
Notes
In the interest of product development specications are
subject to change without notice.
It is the responsibility of the user to ensure compliance with
any acts or by-laws in place.
All information regarding Mechan equipment is believed to
be accurate at the time of printing. Responsibility cannot be
accepted for errors or omissions.
Maintenance
It is recommended to check the safe operation of the of the
switches and look for signs of damage or excessive wear
on a weekly basis. Damaged units should be replaced or
returned to the manufacturer for repair where practical.
Declaration of Conformity
We hereby declare that the products identified below conform to the relevant Essential Health & Safety Requirements of the European
Machinery Directive (2006/42/EC),EMC Directive(2004/108/EC) and other relevant EC Directives as listed below.
Mechan Product Standards
HE Series
SCU-1 Safety Control Unit
HE-1 Safety Switches
HE-2 Safety Switches
HED Safety switches
BS EN60204-1:2006
–
Safety of Machinery, Electrical equipment of machines. General requirements.
BS EN60947-5-3:1999 + AMD 1 04.2005 – Low voltage switchgear and control gear –
Part 5-3: Control circuit devices and switching elements – Requirements for proximity devices with defined behaviour under fault conditions.
BS EN60947-5-1:2004 – Low voltage switchgear and control gear –
Part 5-1: Control circuit devices and switching elements – electro- mechanical control circuits.
EN ISO 13849-1 : 2008 Safety of Machinery, Safety –related Parts of Control Systems
EN 62061 : 2005 Safety of Machinery,-- Functional Safety of Safety elated electrical ,electronic and programmable electronic Control
Systems
BS EN61000-6-4:2007 – EMC Generic emission standard. Industrial.
BS EN61000-6-2:2005 – EMC Generic immunity standard. Industrial.
EC-type examination No. 44 205 10 385597 Notified body 0044, TÜV NORD CERT GmbH, Langemarckstr. 20, 45141 Essen, Germany.
[ 2002/95/EC Restriction of the use of certain Hazardous substances (RoHs) ]
The overall machine must comply with the machinery directive. For further information please contact Mechan Controls Plc.
Authorized Signature
W. Boardman
WA Boardman, Managing Director – July 2011
NORSTAT INC.
300 Roundhill Dr. Rockaway, NJ 07866
www.norstat.com, www.norstatblog.com
PH 973-586-2500, FX 973-586-1590
This manual suits for next models
3
Table of contents