Megawin Writer8 U1Plus User manual

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page1/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
Writer8_U1Plus
User Manual

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page2/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
目錄
1. Introduction ............................................................................................................3
2. On-Line Mode Update ............................................................................................4
3. Off-Line Mode Update............................................................................................6
4. Function Button ......................................................................................................8
4.1. Save Buffer ..................................................................................................................... 8
4.2. Save MPJ......................................................................................................................... 8
4.3. Dump Target................................................................................................................... 8
4.4. Check ID.......................................................................................................................... 8
4.5. Erase ............................................................................................................................... 8
4.6. Blank Check .................................................................................................................... 8
4.7. Program .......................................................................................................................... 8
4.8. Verify .............................................................................................................................. 8
4.9. Write Options ................................................................................................................. 8
4.10. Read Options ................................................................................................................ 9
4.11. WholeChip Erase .......................................................................................................... 9
4.12. Clear.............................................................................................................................. 9
5. Other.....................................................................................................................10
5.1. Language....................................................................................................................... 10
5.2. Check new AP ............................................................................................................... 10
6. Revision History ....................................................................................................11

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page3/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
1. Introduction
Writer8_U1Plus is AP of megawin’s writers(U1Plus). The PC-Site AP corresponding to
U1Plus supports megawin’s 8051 series 8-bit MCUs. In addition to writing the entire
flash area in On-Line mode, Writer8_U1Plus can also write MCU H/W Options.
Moreover, Writer8_U1Plus provides megawin’s standard ISP code and Off-Line mode
functions as well. This AP can also generate MPJ generation tools for customers.
megawin’s writers (U1Plus-D or U1Plus)
If only user connect U1Plus-D and DUT’s board through J9 connector(ICP Interface),
U1Plus-D can program DUT on board.

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page4/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
2. On-Line Mode Update
Step 1. Select Part No
Select a MCU Part No to be updated. If it is found to be incorrect, ID fail will be raised.
After selecting a different Part No, the Code Buffer will be cleared automatically.
Step 2. Load File
Load Bin or Hex file to buffer, after clicking “OK”, users need to choose whether to
place it in the AP area (read into the buffer at 0x00) or IAP (users can define any
location to read into the buffer). Clicking “OK” to see update results in Code Buffer.
Users can Load File repeatedly and overlay files on each other. If users execute Load
File repeatedly, the overlapping file will be overwritten by the last file read. If there is
a blank between the read position of the previous and last files, 0xFF will be filled in.
Check “Clear Buffer” in the “Select Insert Area” dialog. After clicking “OK”, all the
Code Buffer will be cleared and then read into the File.
Step 3. Insert ISP-code
If users need to use ISP function, please click “Insert ISP-code” to insert megawin's
standard ISP code, or choose their own developed ISP code. After clicking “OK”, the
AP will automatically place the ISP code in the address corresponding to the Code
Buffer and set the necessary H/W Options setting concurrently.

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page5/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
Step 4. H/W Options
Customers can set OR setting by themselves. For the description of the setting value,
please refer to the “User Guide: 8. Hardware Option”.
Step 5. Auto
Click “Auto” to set execution options. The preset execution options are: “WholeChip
Erase”, “Blank Check”, “Program”, “Verify”, and “Write Options.” Users can modify
the execution options by themselves.

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page6/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
3. Off-Line Mode Update
Step 1. Select Part No
Step 2. Load File
Step 3. Insert ISP-code
Step 4. H/W Options
Step 5. Off-Line Mode
Click “Off-Line Mode”to download setting (flash & H/W options setting) to U1Plus
H/W. Furthermore, users can also set Max Counter and Serial Number. Max Counter
can control the number of times that U1Plus can perform off-line programming. Its
default value is 0 (meaning unlimited). After Serial Number Enable, 12 strings and 8
numbers can be set and be placed in any position of the Code Buffer. The Serial
Number function can even be implemented by Auto Increment Number.
Click “Read Info” to read the current Off-Line setting in U1Plus H/W.

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page7/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
Step 6. Setup another U1Plus-D
Plug out the writer from PC, repeat “Off-line Mode Update” for another U1Plus-D.
User connect the two writers as shown on the following figure.Press the RUN button
to process the Off-line Copying operation, and then the LEDs will indicate the
programming status:
Blue - the DUT is under programming.
Green - the operation is completed and passed.
Red - the operation is failed.
PS Tester signal interface
GND: Ground.
5V: 5V power.
3V: 3V power.
GND: Ground.
BUSY: the DUT is under programming, active high.
OK: the operation is completed and passed, active high.
NG: the operation is failed, active high.
Start_H: Tester triggers Run Button, active high.
Start_L: Tester triggers Run Button, active low.
GND: Ground.

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page8/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
4. Function Button
4.1. Save Buffer
Click “Save Buffer”can save data in BIN file from Code Buffer.
4.2. Save MPJ
Click “Save MPJ”can save MPJ file. The MPJ file records the contents of the Code
Buffer and the current setting of the H/W Option. Users can read the MPJ file
through “Load File” and read back all settings. The MPJ file is also necessary
information provided by users before megawin burns codes for customers. After
users generate the MPJ file that needs to be burned, the AP will also generate an
“MPJ Request Form” as a confirmation between megawin and users.
4.3. Dump Target
Click “Dump Target”to load flash data from MCU.
4.4. Check ID
Click “Check ID”to confirm if MCU ID is the same as PartNo.
4.5. Erase
Click “Erase”to erase all flash from MCU.
4.6. Blank Check
Click “Blank Check”to check flash is 0xFF from MCU.
4.7. Program
Click “Program”to download Code Buffer data to MCU flash.
4.8. Verify
Click “Verify”to check whether Code Buffer data is consistent with MCU flash.
4.9. Write Options
Click “Write Options”to write H/W Options to MCU.

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page9/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
4.10. Read Options
Click “Read Options”to read H/W Options from MCU.
4.11. WholeChip Erase
Click “WholeChip Erase”to erase flash and H/W Options. This function can unlock ID
Lock.
4.12. Clear
Click “Clear” button to clear all information in Message.

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page10/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
5. Other
5.1. Language
Click Logo in the upper left corner of the UI to select the language from “Language.”
5.2. Check new AP
By clicking Logo in the upper left corner of the UI, users can open the interface from
“Update Writer8 U1Plus”Or they may click “Check” to check if there is a new version
on the official website. If there is a new version, users can directly click “Download”
to download.
Check “Show update message when start”, users can set to automatically detect if
there is a new version when the AP start on.

Writer8_U1Plus
User Manual v1.2.0.0
This document information is the intellectual property of Megawin Technology Co., Ltd page11/11
© Megawin Technology Co., Ltd. 2020 All rights reserved
6. Revision History
Revision
Description
Date
v1.0.0.7
Initial version
2021/04/16
v1.1.0.0
Support 89Series/82L(E)52/82L(E)54/82G516
Support 82FL(E)532/82FL(E)564/5A32/5A64/84FG516
Support 5B08/5B16/5B24/5B32/5C32/5C64/5D16/5E32
Support 6D16/6D17/6D32/6D64
2022/02/16
v1.2.0.0
Support MG82F5Bxx
Support MG82F6B08/001/104
2022/05/30
Table of contents