Melody MDA2 User manual

MODEL: MDA2
Owner’s Manual

Model: MDA2
1
Print edition MELODY INTERNATIONAL HOLDINGS PTY LTD
preface:
Thank you very much for using the MDA2 vacuum tube Integrated amplifier.
MELODY HIFI products are designed and manufactured with a high standard concept
to ensure high quality sound regeneration and long service life. To ensure that you
enjoy the highest quality of MELODY brand equipment. Before you install or attempt
to operate this device, please read and understand the following instructions carefully.
Familiarity with the product and its correct operating procedures will help you ensure
maximum music enjoyment and reliable operation.
packing
Keep all packaging in a dry place for future maintenance or moving of your equipment.
The original packaging can save your investment and cause unnecessary damage and
cost.
Unpacking
The MDA2 is a very exquisite equipment, packed in two layers of cartons inside and
outside. Please check the packing case carefully for damage, damage or wet marks
before unpacking. The pure cotton gloves provided in the packing box are to prevent
fingerprints on the surface of the equipment and the hand slipping during handling.
"Melody" products are very heavy. When you carry them, it must be done by two or
more people.
The accessories in the box are as follows:
xOne instruction manual
xOne power cord
xwo spare safety tubes
xOne warranty card
xOne glove
xOne remote control
xOne slotted screwdriver (for regulating bias voltage)
xOne pair of aaa1.5v batteries
Warning
In order to reduce the risk of electric shock, do not remove the bottom cover of the
chassis. To avoid fire and electric shock hazards, do not let the equipment get wet or
damp. If maintenance is needed, please ask qualified maintenance personnel or send
them to local dealers repair one

Model: MDA2
2
Print edition MELODY INTERNATIONAL HOLDINGS PTY LTD
Preparation before use
Your MDA2 amplifier and vacuum tube are packed in sponge. These sponges that
protect the vacuum tubes must be removed before you attempt to operate the
amplifier.
Front panel function description
xPower indicator: LED (yellow)
xWhen the machine is turned on, the indicator light is yellow
xPower switch on / off (in front of the machine)
xIt is used to turn on and off the amplifier power supply
xTransfer switch: I II III IV V
xIt is used to select the sound source, and five channels of sound source input
can be selected.
xvolume control knob
xThis knob can control the volume of the sound. The volume is gradually
increased by turning it clockwise, and the volume is gradually increased by
turning it anticlockwise Gradually decrease.
xAdjust the tube current switch
xIt is used to adjust the current of output power transistor 2A3, and each 2A3
tube is adjusted to 30~35mA.
Warm tips: MELODY company reminds you not to blindly pursue perfect sound quality,
24 hours a day. This method is not suitable for vacuum tube amplifier. Because the
service life of the electronic tube is only 2000 hours, equivalent to 84 days

Model: MDA2
3
Print edition MELODY INTERNATIONAL HOLDINGS PTY LTD
connect
Function description
¾There are 4 groups of signal input terminals (represented by numbers 1, 2, 3 and
4)
For input source
¾A set of balanced input terminals (indicated by the number5).
For input source (when you use balanced input signal, also connect a set of RCA
signals. Because the balance is not grounded at this time, it is grounded through
RCA signal)
¾Three groups of horn terminals, (left and right channels)
`
used to connect left and right channel speakers
¾One power input socket, fuse holder
AC 240V ~ power supply voltage is input from this, and a fuse is installed in the fuse
holder. Please use the same specification fuse when replacing the fuse.
Important note: for the best sound effect, please connect your whole system with
better quality signal line and horn line. In order to achieve the correct pronunciation
of the audio signal, the red or "+" speaker terminal lead is connected to the MDA2 "4"
or "8" ohmic impedance terminal. Connect the black or "- speaker terminal lead to the
MDA2 " 0 "ohm impedance terminal.

Model: MDA2
4
Print edition MELODY INTERNATIONAL HOLDINGS PTY LTD
Connection diagram

Model: MDA2
5
Print edition MELODY INTERNATIONAL HOLDINGS PTY LTD
install
Place the MDA2 on a stable surface that can bear its weight, and always ensure that the
equipment works in a dry and ventilated environment. If the equipment is placed on the equipment
rack, make sure that sufficient air flow is provided and the surrounding operating temperature
should not exceed 49 ϶C. There should be at least 12 inches of unrestricted ventilation in the upper
and lower spaces. We do not recommend running the device in a closed cabinet.
Operation instructions
¾Before starting the machine, please check again to make sure that your system connection is
correct.
¾Before starting the machine, please confirm again whether your input power supply voltage
is equal to the input power supply provided by this device The pressure is the same.
¾After confirming that there is no error, you can turn on the power switch button from "off" to
"on", The indicator light will be yellow. Indicates that the machine is working normally. (Note:
if the indicator light is not on, turn off the power switch to "off" and check whether the fuse
is blown. If the fuse is blown out, please reinstall it with the spare fuse provided by us,
otherwise contact the dealer or our company).
¾After your sound source works normally, you can enjoy high-quality music by selecting the
correct channel and adjusting the volume control knob to the appropriate volume. After an
hour, your system will be at its best.
Safety instructions
¾Never disassemble or disassemble the equipment without permission, so as to avoid
contact with dangerous voltage, even when the equipment is off. To prevent failure, please
contact the nearest
¾don't try to change any component of the equipment. The equipment has been inspected
and tested by professional laboratory before delivery and has been adjusted to the best
operation mode.
¾At high temperature, the vacuum tube will emit heat:
1. Do not touch the vacuum tube to avoid serious burns.
2.Do not expose vacuum tubes to moisture. Any droplet will cause tube burst damage or
equipment spark.
3.Do not keep the device out of reach of children and pets.
¾the device away from any heat source or flammable chemicals.
¾the equipment in use must correspond to the voltage for your country. Do not attempt to
change components to apply to others Voltage. The switch of the equipment should be in the
state of off when not in use for a long time or in thunderstorm.
¾If smoke, fire, abnormal sound or smell occurs, please turn off the power switch immediately
Note: 1. Do not unplug and plug signal wires or horn wires when your sound system is working,
so as not to damage the unit and other equipment. 2. After turning off the power switch, the
power switch should be turned on after an interval of 5 minutes to avoid damaging the
vacuum tube Contact dealers or MELODY.

Model: MDA2
6
Print edition MELODY INTERNATIONAL HOLDINGS PTY LTD
Cleaning and maintenance
¾must cut off power supply when maintenance.DŽ
¾be used for Aluminum alloy surface clean. Please use soft cotton cloth when wiping, no It
will scratch the surface of the equipment.
¾Pu painting surface cleaning car wax water used for cleaning. Please use soft cotton cloth
when wiping, Otherwise it will scratch the surface of the equipment.
¾to avoid using any kind of thinner, alcohol, or other volatile liquid to wipe. Because they are It
can damage the surface layer and cause spots on the surface to affect the aesthetics of the
equipment.
The warranty
¾the equipment warranty period is two years. (Vacuum tube is guaranteed for six months)
¾within the period of responsibility, the company ensure the quality of products under the
normal use of maintenance of the problem. conditions It was licensed for repair and shipped
to the warranty or back to MELODY.
¾if you don't get the company allowed to open the machine, the warranty commitment.
¾
Note: Information in this manual is subject to change without prior notice

Model: MDA2
7
Print edition MELODY INTERNATIONAL HOLDINGS PTY LTD
Technical Specifications
Power output: 2X13 Watts (Class AB1)
Tubes: 2A3 x4ǃXF184 x 4ǃWE407x1.
Frequency response: 20Hz ~ 30KHz
Signal to noise ratio: 85 dB
Harmonic distortion: 1%
Input sensitivity: 480mV
Output impedance: 4ɏǃϴɏ
Supply voltage: ~240V±5%ˈ50Hz
Dimensions: 475X390X245MM (WxDxH)
Net weight: 39.5KG
Note: For continuous improvement, we reserve the right to change specifications without prior
notice.

!"#$%
&'()*(
+,(
Melodyhifi (Shenzhen) Co. LTD
Baolong Industrial Zone, Longgang Street, Longgang District, Shenzhen city, Guangdong Province
Floor 6, Building C, New Genera�on Shuanghuan Informa�on Industry Park, No. 8, Baoqing Road
Zip code: 518116
Telephone: + 0755-89529002
Website: www.melodyhifi.com.au
Table of contents
Other Melody Amplifier manuals

Melody
Melody Everest211 User manual

Melody
Melody PM845max User manual

Melody
Melody WE2688Signature User manual

Melody
Melody MP211 User manual

Melody
Melody PRO88 MKII User manual

Melody
Melody Dark Power 300B-1 User manual

Melody
Melody DPM80 User manual

Melody
Melody Everest845 User manual

Melody
Melody DARK 300B User manual