"LABEL REPRESENTATION"
WARNOCK LISTED GAS-FIRED DIRECT VENT ROOM HEATER
HERSEY POÊLE AU GAZ HOMOLOGUE’, A AÉRATION DIRECTE
GAS LOGO MODEL: SDV40 MEDALLION
CERTIFIED FOR CANADA HOMOLOGUÉ POUR LE CANADA
Also for use in mobile (manufactured) homes after first sale of home. Convenant également pour installations dans des maisons mobiles.
Tested to (Testé aux normes) ANSI Z21.11.1-1993, CAN1-2.1-M89, CAN/CGA 2.17-M91, ANSI Z21.50-1996 and CAN/CGA 2.17--M91,ANSI Z21.50-1996-CSA 2.22-M96, UL
307B-1996. _________________________________________________
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, or loss of life. Refer to the owner's information manual
provided with this appliance. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Use only glass assemblies certified for use with this
appliance. Do not operate with glass panel(s) removed, cracked, or broken.
MISE EN GARDE: Installation, réglage, modification, entretien ou depannage non appropriés pourront causer des blessures ou des dommages materiels. Réferéz-vous au manuel du
proprietaire fourni avac cet appariel. Pour assistance ou renseignements complémentaires, veuillez consulter un installateur expérimenté, une agence dé depannage/entreitien ou cotre
compagnie gaziére. Pour utilisation avec les portes en verre certifiée l'appareil suelement. Ne pas opérer avec le verriére enlever, craquelure, brise.
NOT FOR USE WITH SOLID FUEL (NE DOIT PASÉ UTILISÉ AVEC UN COMBUSIBLE SOLIDE)
NATURAL GAS
(Gaz Naturel) PROPANE GAS
(Gaz de petrole liquefie (GPL))
Input Rating (Btu/hr) 0-1370 m (Entrée nominale) 40,000 35,000
Min. Input Rating (Btu/hr) 0-1370 m (Mininale Entrée nominale) 27,800 26,100
Orifice (DMS) )-1370 m (Orifice) 30 50
Maximum output (Btu/hr) (Sortie maximale) 31,300 27,800
Manifold Pressure (in w.c./kPa) (Pression au collecteur) 3.5/0.87 10.0/2.5
Manifold Pressure, low (in w.c./kPa) Pression d'entree minimale) 1.7/0.42 3.6/0.90
Minimum Inlet Pressure (in w.c./kPa) (Pression d'entrée minimale) 5.0/1.25 11.0/2.75
_______________________________________________
This appliance must be installed in accordance with local codes if any; If not, follow ANSI Z223.1 or CAN/CGA-B149. Mobile (Mfd.) home installations must adhere to Title 24 CFR,
Part 3280, or CSA Z240.4.
Cet appareil sera installé conformémént avec les codes locaux, le cas écheant. Si aucun code n'existe, suivez la norme ANSI Z223.1 ou la norme CAN/CGA (ACNOR)-B149.
_______________________________________________
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to sidewall 10 in. (255 mm) Unit top to ceiling 39 in. (990 mm.)
Unit to backwall 2 in. (50 mm.) Outlet vent to enclosure top 4 in. (105 mm.)
CAUTION: Hot whil in operation. Do not touch. Keep children, clothing, furniture, and flammable liquids or vapors away. ATTENTION: L'appareil est chaud lorsqu'il fonctionne.
Ne pas toucher l'appareil. Survieller les enfants. Garder les vétements, les meubles, l'essence ou autres liquides a capeur inflammables loin de l'appareil.
_______________________________________________
Electrical Rating (Courant nominal): 120 volts 60 Hz Less than 1 Ampere
_______________________________________________
Manufactured by (Fabriqué par): JOHNSON GAS APPLIANCE
CEDAR RAPIDS, IOWA
DO NOT REMOVE OR COVER THIS LABEL
VEILLEZ Á NE JAMAIS ENLEVER NI DISSIMULER CETTE ÉTIQUETTE
WH# __________________
TEST STANDARD CERTIFICATION
Gas appliances must be tested and certified by a nationally recognized testing and certification laboratory to ANSI (American National Standards Institute) gas
appliance safety standards.
The Mendota Gas Stove has been tested and certified by Intertek Testing Services, 8431 Murphy Drive, Middleton, Wisconsin 53562 to ANSI1 Z21.11.1-1993
"Vented Room Heaters"; CAN 2.1-M89 "Vented Room Heaters"; CAN/CGA 1.17-M91 "Gas-Fired Appliances for use at high altitudes"; ANSI Z21.50-1996,
CGA 2.22-M96 "Vented Gas Fireplaces; and UL307B-1987 "Gas Burning Heating Appliances for mobile homes, not for use with solid fuel.
The Mendota Gas Stove has met all necessary AGA/ANSI Standards and is fully certified for installation in any community.
MAIN GAS CONTROL INSTALLATION
1. DO NOT USE THIS STOVE IF ANY PART HAS BEEN UNDER WATER OR EXPOSED TO MOISTURE CORROSION. IMMEDIATELY CALL A
QUALIFIED SERVICE TECHNICIAN TO INSPECT THE STOVE AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS
CONTROL WHICH HAS BEEN UNDER WATER.
2. DO NOT insert any object other than suitable pipe or tubing in the inlet or outlet of the main gas control. Internal damage may occur and result in a
hazardous condition.
3. DO NOT connect the Stove before pressure testing gas piping and checking for gas leaks. Damage may result causing gas leakage.
4. DO NOT grip gas control body with a pipe wrench or vise. Damage may result causing gas leakage. Use inlet or outlet bosses, or special body wrench.
5. DO NOT use "off/on/pilot" gas knob to adjust gas flow.
6. Leak test with a soap solution with main burner "ON".