METREL A 1832 User manual

METREL test and measurement accessories:
Mode 3 Charging Cable Adapter
A 1832
Instruction manual
Version 1.1.1, Code no. 20 753 362

2
Distributor:
Manufacturer:
Metrel d.o.o.
Ljubljanska cesta 77
SI-1354 Horjul
Slovenia
e-mail:[email protected]
https://www.metrel.si
Mark on your equipment certifies that it meets requirements of all subjected EU
regulations.
Hereby, Metrel d.o.o. declares that the A 1832 is in compliance with subjected EU
directive. The full text of the EU declaration of conformity is available at the
following internet address https://www.metrel.si/DoC.
Mark on your equipment certifies that it meets requirements of all subjected UK
regulations.
Hereby, Metrel d.o.o. declares that the A 1832 is in compliance with subjected
UK regulations. The full text of the UK declaration of conformity is available at the
following internet address https://www.metrel.si/UK-DoC.
© 2023 METREL
No part of this publication may be reproduced or utilized in any form or by any means
without permission in writing from METREL.

A 1832 Mode 3 Charging Cable Adapter Table of contents
3
Table of contents
1Preface ....................................................................................................................4
2Safety and operational considerations.................................................................5
2.1 Warnings and notes ..........................................................................................5
2.2 Markings on the adapter....................................................................................5
2.3 Standards applied .............................................................................................6
3A 1832 standard set and accessories...................................................................7
4Adapter description................................................................................................8
5A 1832 operation.....................................................................................................9
6Maintenance............................................................................................................9
6.1 Cleaning............................................................................................................9
6.2 Service ..............................................................................................................9
7Technical specifications......................................................................................10
7.1 General data....................................................................................................10

A 1832 Mode 3 Charging Cable Adapter Preface
4
1 Preface
The A 1832 is intended for testing Mode 3 EV charging cables with type 2 connector. Different
tests can be carried out in combination with Metrel safety testers.

A 1832 Mode 3 Charging Cable Adapter Safety and operational considerations
5
2 Safety and operational considerations
2.1 Warnings and notes
In order to maintain the highest level of operator safety while carrying out various tests and
measurements METREL recommends keeping your Mode 3 Charging Cable Adapter in good
condition and undamaged. When using the adapter, consider the following general warnings:
❑Warning on the A 1832 means »Read the Instruction manual with special care
for safe operation«. The symbol requires an action!
❑If the A 1832 is used in a manner not specified in this Instruction manual or the
Instruction manual of target test equipment, the protection provided by the A 1832
and test equipment may be impaired!
❑Do not use the A 1832 if any damage is noticed!
❑Test input is intended to connection to mains test socket of electrical equipment
testers only.
❑Banana sockets are intended for test purposes only.
❑Do not connect the adapter to mains voltage.
❑Do not connect the carry out tests with mains voltage applied to the adapter!
❑All normal safety precautions have to be taken in order to avoid risk of electric
shock!
❑Service intervention is allowed to be carried out only by a competent authorized
personel!
2.2 Markings on the adapter
»Warning »Read the Instruction manual with special care to safety
operation«.
Mark on your equipment certifies that it meets requirements of all subjected EU
regulations.
Mark on your equipment certifies that it meets requirements of all subjected UK
regulations.
This equipment should be recycled as electronic waste.

A 1832 Mode 3 Charging Cable Adapter Safety and operational considerations
6
2.3 Standards applied
The A 1832 adapter is manufactured and tested in accordance with the following
regulations:
Safety (LVD)
EN 61010 - 1
Safety requirements for electrical equipment for measurement, control
and laboratory use –Part 1: General requirements
EN 61010 - 2 - 030
Safety requirements for electrical equipment for measurement, control
and laboratory use –Part 2-030: Particular requirements for testing and
measuring circuits
EN 61010 - 031
Safety requirements for electrical equipment for measurement, control
and laboratory use –Part 031: Safety requirements for hand-held probe
assemblies for electrical measurement and test
Functional
EN IEC 61851 - 1
Electric vehicle conductive charging system Part 1: General
requirements

A 1832 Mode 3 Charging Cable Adapter A 1832 standard set and accessories
7
3 A 1832 standard set and accessories
❑Mode 3 Charging Cable Adapter (A 1832)
❑Test instrument connection cable, 3 x 0.75 mm2, 1.5 m
❑Instruction manual

A 1832 Mode 3 Charging Cable Adapter Adapter description
8
4 Adapter description
Figure 4.1: A 1832 front panel
Legend:
1
Test input for connection of test instrument to the charging cable’s input side
2
LEDs for indication of continuity of phase and neutral conductors (L1, L2, L3, N)
3
Banana sockets for connection of test instrument and to the tested charging cable (all
connections on input and output side)
4
Connectors for Mode 3 charging cable

A 1832 Mode 3 Charging Cable Adapter Maintenance
9
5 A 1832 operation
In combination with Metrel safety testers, the adapter enables to carry out different safety
tests, for example:
❑Continuity of PE conductor
❑Continuity of L1, L2, L3, N conductors
❑Continuity of CP conductor
❑Resistance of PP coding resistors
❑Fast continuity check of L1, L2, L3, N conductors with LEDs, by using Sub Leakage test
❑Insulation of phase conductors to earth
Figure 5.1: Application example using MI 3365 and A 1832 (Continuity of PE conductor)
Note
❑For more information about carrying out other tests with A 1832, refer to Metrel’s MI
3365 Application notes, and test instruments user manuals.
6 Maintenance
Unauthorized person is not allowed to open the A 1832 Mode 3 Charging Cable Adapter. There
are no user replaceable components inside the adapter.
6.1 Cleaning
No special maintenance is required for the housing. To clean the surface of the adapter, use a
soft cloth slightly moistened with soapy water or alcohol. Then leave the A 1832 to dry totally
before use.
Warnings:
❑Do not use liquids based on petrol or hydrocarbons!
❑Do not spill cleaning liquid over the adapter!
6.2 Service
For repairs under warranty, or at any other time, please contact your distributor.

A 1832 Mode 3 Charging Cable Adapter Technical specifications
10
7 Technical specifications
7.1 General data
Charging cable connectors………………Type 2
Maximum test current............................ 10 A on test connector / 25 A on banana sockets
Measuring category............................... 50 V no CAT, max. transient overvoltage 1100 V
Protection classification......................... double insulation
Altitude ............................................... 2000 m
Pollution degree..................................... 2
Protection degree.................................. IP 40
Dimensions (w h l)........................... 30 cm 15 cm 34 cm
Weight ................................................ 3.16 kg
Operation conditions
Working temperature range................... 0C …40 C
Maximum relative humidity .................... 95 %RH (0C …40 C), non-condensing
Operation............................................... Outdoor use
Storage conditions
Temperature range................................ -10C …+70 C
Maximum relative humidity .................... 90 %RH (-10C …+40 C)
80 %RH (40C …60 C)
Table of contents