BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner .............................................................. (1)
Mounting screw (M3.5 × 10).............................................. (2)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%,
approx. 25mA with voltage output 1
approx. 45mA with current output 1
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Be sure to put the terminal cover on while the power is
supplied.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Zero Adj.
Span Adj. Output 1
Body
Specifications
Connection Diagram
(side)
Zero Adj.
Output 2*Span Adj.
Terminal Cover
*Provided only when the second output is selected.
INSTALLATION
Use Standard Rack (model: 10BXx).
OUTPUT ISOLATOR MODEL
10YS/10YK
EM-0871 Rev.4 P. 1 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
130 (5.12)
3 (.12)
51 (2.01)
82 (3.23)
2–4.3 (.17) dia.
MTG HOLE
TERMINAL COVER
7–M3.5 SCREW
8 (.31)
91 (3.58)
99 (3.90 )
25 (.98)
12
3
56
78
■CONNECTION DIAGRAM
+
–
+
–
INPUT MONITOR
1
OUTPUT 1
2
7
8
+
–
OUTPUT 2
5
6
CONNECTOR
POWER
INPUT
Note: The section enclosed by broken line is only for 2nd output channel.
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 10BXx). For the DC power source, be sure that
the ripple level is within 10% p-p.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
5) Go through the same procedure for Output 2. Extender
Card (model: 10EC) is required to access the Output 2
Adjustments on top of the unit maintaining electrical
connection at the rear connector.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.
10YS / 10YK
EM-0871 Rev.4 P. 2 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

This manual suits for next models

1

Other MG I/O System manuals

MG R7F4DC-DC16A-H User manual

MG

MG R7F4DC-DC16A-H User manual

MG R8-DAT8B2 User manual

MG

MG R8-DAT8B2 User manual

MG Mini-M M2VV User manual

MG

MG Mini-M M2VV User manual

MG M2BS-16U0 User manual

MG

MG M2BS-16U0 User manual

MG M6DBS User manual

MG

MG M6DBS User manual

MG Devicenet R7F4HD-DA32A User manual

MG

MG Devicenet R7F4HD-DA32A User manual

MG DS-824 User manual

MG

MG DS-824 User manual

MG M2BS-8U1 User manual

MG

MG M2BS-8U1 User manual

MG DLS-R1 User manual

MG

MG DLS-R1 User manual

MG Devicenet R7F4DD-DA16B-H User manual

MG

MG Devicenet R7F4DD-DA16B-H User manual

MG R7K4FML3-6-DA32-1 User manual

MG

MG R7K4FML3-6-DA32-1 User manual

MG R1M-J3 User manual

MG

MG R1M-J3 User manual

MG DLC-C1 Series User manual

MG

MG DLC-C1 Series User manual

MG R7HL-YS4L User manual

MG

MG R7HL-YS4L User manual

MG R7F4HD-DA32B User manual

MG

MG R7F4HD-DA32B User manual

MG M6DYV User manual

MG

MG M6DYV User manual

MG DLC E2 Series User manual

MG

MG DLC E2 Series User manual

MG R6D-SV2 User manual

MG

MG R6D-SV2 User manual

MG Mini-M M2PDU User manual

MG

MG Mini-M M2PDU User manual

MG R6N-SS2 User manual

MG

MG R6N-SS2 User manual

MG R30XN16A User manual

MG

MG R30XN16A User manual

MG R30BS User manual

MG

MG R30BS User manual

MG R7K4FML3-6-DC32B User manual

MG

MG R7K4FML3-6-DC32B User manual

MG R1M-GH User manual

MG

MG R1M-GH User manual

Popular I/O System manuals by other brands

M-system R7ML-DA16 instruction manual

M-system

M-system R7ML-DA16 instruction manual

Siemens SIMATIC ET 200iS manual

Siemens

Siemens SIMATIC ET 200iS manual

GE VersaPoint IC220ALG221 System manual

GE

GE VersaPoint IC220ALG221 System manual

CREVIS FnIO SSeries Quick start manual

CREVIS

CREVIS FnIO SSeries Quick start manual

Profire Energy PF2100 user manual

Profire Energy

Profire Energy PF2100 user manual

Crestron DMB-4K-CPU-128 Installation guides

Crestron

Crestron DMB-4K-CPU-128 Installation guides

Allen-Bradley Compact 5000 Series user manual

Allen-Bradley

Allen-Bradley Compact 5000 Series user manual

ICP DAS USA P8R8-DIO quick start guide

ICP DAS USA

ICP DAS USA P8R8-DIO quick start guide

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Allen-Bradley

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Extron electronics TLP VIM user guide

Extron electronics

Extron electronics TLP VIM user guide

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

National Instruments

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

ETAS ES930.1 user guide

ETAS

ETAS ES930.1 user guide

Measurement Computing USB-3103 user guide

Measurement Computing

Measurement Computing USB-3103 user guide

SeaLevel SeaRAQ 6510 user manual

SeaLevel

SeaLevel SeaRAQ 6510 user manual

EverFocus External I/O Box quick start guide

EverFocus

EverFocus External I/O Box quick start guide

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Advantech

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Future Desion Controls FDC-VR18 quick start guide

Future Desion Controls

Future Desion Controls FDC-VR18 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.