EM-7821 Rev.7 P. 1 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
ISOLATOR MODEL M6DYV
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES OR UL
• This equipment is suitable for Pollution Degree 2 and In-
stallation Category II (transient voltage 2500V). Rein-
forced insulation (signal input or output to power input:
300V) and basic insulation (signal input to output: 300V)
are maintained. Prior to installation, check that the insu-
lation class of this unit satisfies the system requirements.
• The equipment must be mounted inside a panel.
• Altitude up to 2000 meters.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformance.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lighting surge protectors for those wires connected
to remote location.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
100 – 240V AC rating: 90 – 264V, 47 – 66 Hz, ≤ 2VA
24V DC rating: 24V ±10%, approx. 0.45W
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +55°C
(-4 to +131°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Front Cover
DIN Rail Adaptor
Specifications
■FRONT VIEW (with the cover open)
Zero Adj.
Power LED
Span Adj.
M6DYV
EM-7821 Rev.7 P. 2 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom. When the unit is installed to an Installation Base (model M6DBS),
refer to its instruction manual.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook at the rear side of unit on the DIN
rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
DIN Rail
AB
■REMOVING THE UNIT
A)Pull down the DIN rail adaptor using a minus screwdriv-
er.
B)Pull out the lower part of the unit.
C)Remove the upper part from the DIN rail.
DIN Rail Adaptor A
B
C
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
94 (3.70)
5.9 (.23)
DIN RAIL HOOK
102 (4.02)
[0.5 (.02)]
8–M3
EURO TERMINAL
DIN RAIL
35mm wide
5678
1234
• When mounting, no extra space is needed between units.
WIRE INSERTION ANGLE: approx. 7°
SCREWDRIVER
INSERTION ANGLE
: approx. 40°
M6DYV
EM-7821 Rev.7 P. 3 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■CONNECTION DIAGRAM
+
–
OUTPUT
5
6
8
+
–
INPUT
1
2
U (+)
V (–)
POWER
POWER*
* Available only for DC power input type
7
CONNECTOR
■WIRING INSTRUCTIONS
• Applicable wire size
Solid: 0.2 to 2.5 mm2(0.55 to 1.75 dia.)
Stranded: 0.2 to 2.5 mm2(Tinning wire ends may
cause contact failure and therefore is not
recommended.)
Ferruled: 0.2 to 1.5 mm2(0.55 to 1.35 dia.)
• Expose wire conductors by 8 mm (0.31”).
8 mm 8 mm
3.7 mm dia.
max.
3.7 mm dia.
max.
Wire exposure Recommended
ferruled wire
• How to Connect Wires
Screwdriver
Wire
Insert a wire. Confirm that the wire tip hits the bottom and
tighten the screw with a screwdriver.
Confirm that the wire’s insulation tube is not caught in the
terminal. (Torque: 0.3 N·m)
Screwdriver
Wire
8 mm
6 mm
M6DYV
EM-7821 Rev.7 P. 4 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
For an bidirectional output (e.g. -10 – +10 V DC), apply
an input signal corresponding to 0 V DC output. (Same
procedure in (3))
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.

Other MG I/O System manuals

MG R3Y-MS8 User manual

MG

MG R3Y-MS8 User manual

MG DLC-C1 Series User manual

MG

MG DLC-C1 Series User manual

MG R3-DA16 User manual

MG

MG R3-DA16 User manual

MG M2BS-16U0 User manual

MG

MG M2BS-16U0 User manual

MG R7E-MS4 User manual

MG

MG R7E-MS4 User manual

MG R8-FS16N User manual

MG

MG R8-FS16N User manual

MG R7HL-YS4L User manual

MG

MG R7HL-YS4L User manual

MG R7F4HEIP-DA16A User manual

MG

MG R7F4HEIP-DA16A User manual

MG DLC E2 Series User manual

MG

MG DLC E2 Series User manual

MG Devicenet R7F4HD-DC32B User manual

MG

MG Devicenet R7F4HD-DC32B User manual

MG DS-824 User manual

MG

MG DS-824 User manual

MG DLS-R1 User manual

MG

MG DLS-R1 User manual

MG R7F4DH-1-DAC16B User manual

MG

MG R7F4DH-1-DAC16B User manual

MG DLS-M1 User manual

MG

MG DLS-M1 User manual

MG R7I4DML3-DC32A User manual

MG

MG R7I4DML3-DC32A User manual

MG 10FNS User manual

MG

MG 10FNS User manual

MG M2BS2 User manual

MG

MG M2BS2 User manual

MG M2BS-8U1 User manual

MG

MG M2BS-8U1 User manual

MG M6DBS User manual

MG

MG M6DBS User manual

MG R7G4FML3-6-DC16A User manual

MG

MG R7G4FML3-6-DC16A User manual

MG R7F4DC-DC16A-H User manual

MG

MG R7F4DC-DC16A-H User manual

MG R7K4FML3-6-DC32B User manual

MG

MG R7K4FML3-6-DC32B User manual

MG R7C-RT4A User manual

MG

MG R7C-RT4A User manual

MG R7F4DC-DC16B-H User manual

MG

MG R7F4DC-DC16B-H User manual

Popular I/O System manuals by other brands

M-system R7ML-DA16 instruction manual

M-system

M-system R7ML-DA16 instruction manual

Siemens SIMATIC ET 200iS manual

Siemens

Siemens SIMATIC ET 200iS manual

GE VersaPoint IC220ALG221 System manual

GE

GE VersaPoint IC220ALG221 System manual

CREVIS FnIO SSeries Quick start manual

CREVIS

CREVIS FnIO SSeries Quick start manual

Profire Energy PF2100 user manual

Profire Energy

Profire Energy PF2100 user manual

Crestron DMB-4K-CPU-128 Installation guides

Crestron

Crestron DMB-4K-CPU-128 Installation guides

Allen-Bradley Compact 5000 Series user manual

Allen-Bradley

Allen-Bradley Compact 5000 Series user manual

ICP DAS USA P8R8-DIO quick start guide

ICP DAS USA

ICP DAS USA P8R8-DIO quick start guide

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Allen-Bradley

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Extron electronics TLP VIM user guide

Extron electronics

Extron electronics TLP VIM user guide

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

National Instruments

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

ETAS ES930.1 user guide

ETAS

ETAS ES930.1 user guide

Measurement Computing USB-3103 user guide

Measurement Computing

Measurement Computing USB-3103 user guide

SeaLevel SeaRAQ 6510 user manual

SeaLevel

SeaLevel SeaRAQ 6510 user manual

EverFocus External I/O Box quick start guide

EverFocus

EverFocus External I/O Box quick start guide

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Advantech

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Future Desion Controls FDC-VR18 quick start guide

Future Desion Controls

Future Desion Controls FDC-VR18 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.