MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
DC voltage input module ....................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches while the power is supplied.
The switches are used only for maintenance without the
power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R5-BS).
DC VOLTAGE INPUT MODULE
(re-transmitted output) MODEL R5-SV1A
EM-7568 Rev.3 P. 1 / 4
INSTRUCTION MANUAL
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
COMPONENT IDENTIFICATION
RUN LED
ON
1
Input
2345678 Zero/Span Adj.
Mode Selector
5
4
3
2
1
0
9
8
7
6
456
123
RUN
UP
DOWN
UP Button
DOWN Button
■
SIDE VIEW ■FRONT VIEW
Euro Type
Connector Terminal
■SIDE DIP SW
• INPUT RANGE: SW1, 2, 3, 4
SW RANGE
1234
OFF OFF OFF OFF -10 – +10V(*)
ON OFF OFF OFF -5 – +5V
OFF ON OFF OFF -1 – +1V
ON ON OFF OFF 0 – 10V
OFF OFF ON OFF 0 – 5V
ON OFF ON OFF 1 – 5V
OFF ON ON OFF 0 – 1V
(*) Factory setting
Note: Be sure to set unused SW5 thorugh 8 to OFF.
R5-SV1A
EM-7568 Rev.3 P. 2 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■ZERO/SPAN ADJ. MODE SELECTOR ROTARY SW
SW MODE *1FUNCTION RUN LED *1
0 (*) Monitor Output % proportional to the Input % Red/Green ON *2
1
2
3
Output 0% adjustment Increments by 1
Increments by 5
Increments by 10
Red Blinking
4
5
6
Output 100% adjustment Increments by 1
Increments by 5
Increments by 10
Green Blinking
7
8
9
Simulated output Simulates output 0%
Simulates output 50%
Simulates output 100%
Orange Blinking
(*) Factory setting
*1. When switching Monitor mode to another, set the rotary switch to a desired SW position and then press UP/DOWN button, so
that the mode is switched. Along with mode switching, RUN LED turns to blinking as shown in the table. Setting the rotary
switch to 0, the mode is automatically switched to Monitor mode in a few seconds.
*2. Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
• Zero/Span Adjustment Modes
Monitor Mode
Re-transmits the input signal as output in proportion.
Output 0% Adjustment Mode
Adjusts the 0% output signal using the front UP/DOWN
buttons, in monitoring the output value with a multimeter.
SW1 through SW3 switch the internal increments by 1, 5
and 10.
Output 100% Adjustment Mode
Adjusts the 100% output signal using the front UP/DOWN
buttons, in monitoring the output value with a multimeter.
SW4 through SW6 switch the internal increments by 1, 5
and 10.
Simulated Output Mode
Outputs the simulated signals of 0%, 50% and 100%.
• How to Operate
1) Start up in Monitor Mode (SW position = 0) and wait for
2 or 3 seconds.
2) Switch to another mode and go through the adjustments.
3) Reset the switch to the position ‘0’ so that the new setting
is stored in the internal memory.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R5CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Bias [Zero Adj.] -320.00 to +320.00 0.00
Gain [Span Adj.] -32000 to +32000 1.0000
R5-SV1A
EM-7568 Rev.3 P. 3 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
456
123
6.5
(.26)
90 (3.54) LOCKING CLAMP
90 (3.54) 5.6
(.22)
18 (.71)
POSITIONING GUIDE
■CONNECTION DIAGRAM
1
2
4
5
+
+
–
INPUT
–
+
3
BUS CONNECTOR
INTERNAL POWER
INTERNAL BUS A
INTERNAL BUS B*
*For dual redundant communication.
Note: Connect either wide or narrow span terminals for each channel.
OUTPUT
NARROW
SPAN
WIDE
SPAN
• Wide span: -10 – +10 V DC, -5 – +5 V DC, 0 – 10 V DC,
0 – 5 V DC, 1 – 5 V DC
• Narrow span: -1 – +1 V DC, 0 – 1 V DC
WIRING INSTRUCTIONS
■EURO TYPE CONNECTOR TERMINAL
Applicable Wire size: 0.2 – 2.5 mm2
Stripped length: 7 mm
R5-SV1A
EM-7568 Rev.3 P. 4 / 4

Other MG I/O System manuals

MG R8-DAT8B2 User manual

MG

MG R8-DAT8B2 User manual

MG R1M-GH User manual

MG

MG R1M-GH User manual

MG R9WTU-ED User manual

MG

MG R9WTU-ED User manual

MG R7F4HD-DAC32C User manual

MG

MG R7F4HD-DAC32C User manual

MG R7K4FML3-6-DAC32B User manual

MG

MG R7K4FML3-6-DAC32B User manual

MG R7F4DH-1-DAC16B User manual

MG

MG R7F4DH-1-DAC16B User manual

MG Devicenet R7F4HD-DC32B User manual

MG

MG Devicenet R7F4HD-DC32B User manual

MG R7I4DML3-DC32A User manual

MG

MG R7I4DML3-DC32A User manual

MG R7K4FML3-6-DC32B User manual

MG

MG R7K4FML3-6-DC32B User manual

MG 10YS User manual

MG

MG 10YS User manual

MG R3-DA16 User manual

MG

MG R3-DA16 User manual

MG R7F4DC-DC16B-H User manual

MG

MG R7F4DC-DC16B-H User manual

MG R7F4HEIP-DA16A User manual

MG

MG R7F4HEIP-DA16A User manual

MG R7I4DECT-1-DC32A User manual

MG

MG R7I4DECT-1-DC32A User manual

MG R30BS User manual

MG

MG R30BS User manual

MG R7K4FML3-6-DA32-1 User manual

MG

MG R7K4FML3-6-DA32-1 User manual

MG R6N-SV2 User manual

MG

MG R6N-SV2 User manual

MG R8-FS16N User manual

MG

MG R8-FS16N User manual

MG DLC-C1 Series User manual

MG

MG DLC-C1 Series User manual

MG Mini-M M2LMS User manual

MG

MG Mini-M M2LMS User manual

MG R30XN16A User manual

MG

MG R30XN16A User manual

MG R6D-SV2 User manual

MG

MG R6D-SV2 User manual

MG R7F4DC-DC16A-H User manual

MG

MG R7F4DC-DC16A-H User manual

MG M2BS-16U2 User manual

MG

MG M2BS-16U2 User manual

Popular I/O System manuals by other brands

M-system R7ML-DA16 instruction manual

M-system

M-system R7ML-DA16 instruction manual

Siemens SIMATIC ET 200iS manual

Siemens

Siemens SIMATIC ET 200iS manual

GE VersaPoint IC220ALG221 System manual

GE

GE VersaPoint IC220ALG221 System manual

CREVIS FnIO SSeries Quick start manual

CREVIS

CREVIS FnIO SSeries Quick start manual

Profire Energy PF2100 user manual

Profire Energy

Profire Energy PF2100 user manual

Crestron DMB-4K-CPU-128 Installation guides

Crestron

Crestron DMB-4K-CPU-128 Installation guides

Allen-Bradley Compact 5000 Series user manual

Allen-Bradley

Allen-Bradley Compact 5000 Series user manual

ICP DAS USA P8R8-DIO quick start guide

ICP DAS USA

ICP DAS USA P8R8-DIO quick start guide

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Allen-Bradley

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Extron electronics TLP VIM user guide

Extron electronics

Extron electronics TLP VIM user guide

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

National Instruments

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

ETAS ES930.1 user guide

ETAS

ETAS ES930.1 user guide

Measurement Computing USB-3103 user guide

Measurement Computing

Measurement Computing USB-3103 user guide

SeaLevel SeaRAQ 6510 user manual

SeaLevel

SeaLevel SeaRAQ 6510 user manual

EverFocus External I/O Box quick start guide

EverFocus

EverFocus External I/O Box quick start guide

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Advantech

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Future Desion Controls FDC-VR18 quick start guide

Future Desion Controls

Future Desion Controls FDC-VR18 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.