86D0024 3
9. The installation must conform with local codes or, in
the absence of local codes, with the National Fuel
10. This unit complies with the latest revision of ANSI
Z21.11.2-2007 Unvented Heaters and also complies
with ANSI Z21.60 Decorative Vented Appliances for
Solid Fuel Burning Fireplaces. State and local codes
may only allow operation of this appliance in a vented
vented operation, see “Vented Instructions” in this
manual.
11. Do not install the heaters in a bathroom or bed-
room.
location of the heater, and annual cleaning are
necessary to avoid potential problems with soot-
ing. Sooting, resulting from improper installation
or operation, can settle on surfaces outside the
installation.
-
terns. Sooting and improper burning will occur.
14. CAUTION: Candles, incense, oil lamps, etc. produce
combustion byproducts including soot. Vent-free
these types of products. In addition, the smoke and/
or aromatics (scents) may be reburnt in the vent-free
appliance which can produce odors. It is recom-
mended to minimize the use of candles, incense,
etc. while the vent-free appliance is in operation.
INSTALLER
Please leave these instructions with the appliance.
OWNER
Please retain these instructions for future reference.
Read these instructions carefully before installing or trying to operate this vent-free gas heater.
8. Early signs
you have these signs, obtain fresh air immediately.
Have the heater serviced as it may not be operating
properly.
continued on page 4
• Do not use a blower insert, heat exchanger insert or other accessory, not approved
WARNING
1. Due to high temperatures, the appliance should
and draperies.
2. Children and adults should be alerted to the haz-
ard of high surface temperature and should stay
away to avoid burns or clothing ignition.
3. Young children should be carefully supervised
when they are in the same room with the appli-
ance.
on or near the appliance.
5. Any safety screen or guard removed for servicing
an appliance, must be replaced prior to operating
the heater.
6. Installation and repair should be done by a quali-
7. To prevent malfunction and/or sooting, an un-
vented gas heater should be cleaned before use
and at least annually by a professional service
person. More frequent cleaning may be required
material, etc. It is imperative that control compart-
ments, burners and circulating air passageways
be kept clean.