CDV7 Series Gas Fireplace
69D3011 5
• This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
• This appliance is not for use with solid fuels.
• The appliance is approved for bedroom or bedsitting
room installations.
• The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.
• This appliance is mobile home approved.
• The appliance must be properly connected to a venting
system.
• The appliance is not approved for closet installations.
• This appliance is approved to be vented with Simpson-
Duravent and MHSC Twist-Lock Direct Vent Compo-
nents.
Off/Pilot/On Knob
Remote Control
Switch Receiver
Figure 1 -
CDV7 Series Fireplace
Hi/Lo Knob
Blower
Control
On/Off/RS
Switch
Ignitor
FP84
The classification “noncombustible material” includes, but
is not limited to stone, brick and mortar. Noncombustibles
are safe to overlay the black-painted metal face (includ-
ing radiant plates) and do not pose a fire hazard. Do not
allow any noncombustible finish material to extend past or
interfere with fireplace opening.
The classification “combustible material” includes, but is not
limited to plywood, drywall and particle board. Combustible
materials may contact the sides, bottom or back of firebox.
Do not overlay the black painted face with combustible
materials.
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
Max.Input Min. Input Orifice
Model Fuel BTU/h BTU/h Size
CDVR33NV7 Nat. 18,000 13,000 #45
CDVR33PV7 LP 18,000 13,000 1.8 mm
CDVR33NE7 Nat. 18,000 13,000 #45
CDVR33PE7 LP 18,000 13,000 1.8 mm
CDVR36NV7 Nat. 0,000 15,000 #44
CDVR36PV7 LP 0,000 15,000 1.35 mm
CDVR36NE7 Nat. 0,000 15,000 #44
CDVR36PE7 LP 0,000 15,000 1.35 mm
CDVR4NV7 Nat. 4,000 17,000 .35 mm
CDVR4PV7 LP 4,000 18,000 1.45 mm
CDVR4NE7 Nat. 4,000 17,000 .35 mm
CDVR4PE7 LP 4,000 18,000 1.45 mm
CDVR47NV7 Nat. 4,000 17,000 .35 mm
CDVR47PV7 LP 4,000 18,000 1.45 mm
CDVR47NE7 Nat. 4,000 17,000 .35 mm
CDVR47PE7 LP 4,000 18,000 1.45 mm
CDVT33NV7 Nat. 18,000 13,000 #45
CDVT33PV7 LP 18,000 13,000 1.8 mm
CDVT33NE7 Nat. 18,000 13,000 #45
CDVT33PE7 LP 18,000 13,000 1.8 mm
CDVT36NV7 Nat. 0,000 15,000 #44
CDVT36PV7 LP 0,000 15,000 1.35 mm
CDVT36NE7 Nat. 0,000 15,000 #44
CDVT36PE7 LP 0,000 15,000 1.35 mm
CDVT4NV7 Nat. 4,000 17,000 .35 mm
CDVT4PV7 LP 4,000 18,000 1.45 mm
CDVT4NE7 Nat. 4,000 17,000 .35 mm
CDVT4PE7 LP 4,000 18,000 1.45 mm
CDVT47NV7 Nat. 4,000 17,000 .35 mm
CDVT47PV7 LP 4,000 18,000 1.45 mm
CDVT47NE7 Nat. 4,000 17,000 .35 mm
CDVT47PE7 LP 4,000 18,000 1.45 mm
Natural Propane (LP)
Inlet Minimum 5.5” w.c. 11.0” w.c.
Inlet Maximum 14.0” w.c. 14.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.