PRODUCT OUTLINE
Technical details
width
projection
width and – width from 180 cm up to 650 cm , coupled from 651 cm up to 1200 cm
projection: – projection 150 / 200 / 250 / 300 / 350 / 400 cm
inclination angle:– adjustable from 0° up to 40°
frame colours: –standard colours:
–white powder coated RAL 9016 (MHZ-no. 171)
–brown powder coated RAL 8019 (MHZ-no. 584)
–silver powder coated RAL 9006 (MHZ-no. 900)
– special colours: as per RAL colour chart
awning fabric: – please see MHZ fabric range for awnings and shading systems
Operation
hand crank for dimensions up to 600 cm width and 350 cm projection
operation: with integrated gear with sliding clutch (GFT), removable crank
in different standard lenght (100, 120, 140, 160, 180, 200 cm).
electric motion: with manual adjustment of limit stops and thermal protection.
Option: motor with integrated radio receiver and hand transmitter.
rain hood: two-part rain hood made of aluminium, powder coated, sealing lip,
side cover, installation with separate fixing bracket on carrier bar.
VERTIMA: drop valance, for width up to max. 600 cm and projection up to
300 cm, integrated inside of special drop bar. Height approx.
150 cm. Operation with removable crank (length 60 cm).
PRISMA: guide bar, for width up to 650 cm and projection up to 350 cm.
Track bar for deflection of fabric in centre area over the joint arms.
Additional equipment
installation on: wall, ceiling (accessory), rafter* (accessory)
Installation (for installation on concrete C20/25, delivery of awning without installation screws respectively dowels)
item no. 08-1851 wall installation
item no. 08-1852 ceiling installation
Retractable awning with square carrier bar, side bearings made of aluminium inclusive cover, circular drop bar with lateral end
caps, fabric tube made of galvanized steel projection up to 350 cm ø 78 mm, for projection 400 cm ø 90 cm. Lateral folding arms,
transmission of power with strap hinge, angle of inclination is adjustable with a spindle. Brackets for installation on concrete
C20/25. Manual operation with crank or electric motion. Awning is with valance (height 20 cm). Coupled awnings with two fabrics
(fabric gap approx. 5 cm, valance in 1 piece).
width of awning
from 180 cm
from 230 cm
from 280 cm
from330 cm
from 380 cm
from 430 cm
maximum projetion
150 cm
200 cm
250 cm
300 cm
350 cm
400 cm
* inclination angle
DIN EN 13561
wind resistance category 2
Advice: the delivered installation brackets are for installation on concrete
C20/25. Other installation substructure, as well as installation on insulated
plaster is mandatory to be mentioned with the order, because other installa-
tion brackets or accessories could be necessary (additional charge). Please
consider the extraction forces.
*Advice: for installation on wood, wind resistance category 0 is valid.
Advise to DIN EN 13561
The standard delivered brackets are for installation on
concrete C20/25. Due to static reasons, it is mandatory
to advise with the order, if there is an other installation
substructure, or installation on insulated plaster, then it
is necessary to use different brackets, respectively other
accessories (additional charge).

T1-31
Subject to technical changes, edition 03.2008
MHZ carrier bar awning CLASSIC
*Advice: for orders without details of installation substructure you will receive brackets for the installation on concrete C20/25. Please consider the
respective extraction forces depending on the installation substructure and the bracket set. Other installation substructure, as well as installation on
insulated plaster is mandatory to be mentioned at order, because other accessories could be necessary (additional charge).
MODEL ILLUSTRATION
order details please use order form for awnings (www.mhz.de)
4
6
5
2
3
1
11. awning fabric
12. side bearing with cover
13.wall bracket (installation on concrete)
14. fabric tube
15. carrier bar
16. arm bracket / adjustment
for angle of inclination
17. joint arm
18. drop bar with end caps
9. valance with binding
8
9
item no.
frame colours
width
projection
fabric no.
Design of valance
colour of valance binding
mode of operation
operation side (seen from outside)
length of crank
installation
installation substructure*(maybe additional charge)
additional equipment
accessories
7
guide bar PRISMA (additional charge)rain hood (additional charge)
drop valance VERTIMA (add. charge)
light bar (additional charge)
please see page T1-41
additional equipment

MHZ carrier bar awning
CLASSIC
T1-32
Subject to technical changes, edition 03.2008
230 mm
260 mm
230 mm
235 mm
TECHNICAL DETAILS
wall installation
standard wall bracket
for installation on concrete
(delivered with awning)
ceiling installation
standard ceiling bracket
for installation on concrete
(additional charge)
If required we will send to you 1:1 drawings of our awning constructions for wall and ceiling installation.
60
20
84
150 mm
96
225 mm
85 49
96
60
85
37
154 mm
230 mm
296 mm
315 mm
wall installation with rain hoodwall installation
ceiling installation
*Please note: for installation on wood wind resistance category 0 is valid. The maximum projection is 300 cm. Please check static
of wooden construction before. Please draw a sketch with position of awning, rafters and the space between. Please ask for form
sheet " measurement of center to center brackets CLASSIC".
rafter bracket*
(accessory)
140
max.
150
160 mm
WK 1
DK 1

T1-33
Subject to technical changes, edition 03.2008
MHZ carrier bar awning CLASSIC
245 mm
235 mm
245 mm
260 mm
TECHNICAL DETAILS
230 mm
235 mm
dimension 1
dimension 2
projection
guide bar
Guide bar PRISMA
Drop valance VERTIMA
additional dimension data
* angle of dimen- projection in cm
inclination sion 150 200 250 300 350
0°
5°
10°
15°
20°
25°
30°
35°
40°
23
147
36
143
49
139
62
133
75
127
88
120
101
111
115
102
129
92
230 mm
260 mm
* angel of inclination
26
197
43
193
61
187
78
180
95
172
112
162
130
152
149
140
168
127
29
246
50
242
72
235
94
227
115
217
137
205
160
192
183
177
207
161
32
296
58
291
84
283
109
274
136
262
162
248
189
232
217
215
246
196
34
346
65
340
95
331
125
320
156
307
187
291
218
273
251
252
286
230
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
wall installation
wall installation
ceiling installation
ceiling installation
dimension data in cm
up to projection of 350 cm

MHZ carrier bar awning
CLASSIC
T1-34
Subject to technical changes, edition 03.2008
Measurement of axes A1, A2 in cm for installation on concrete
width of projection of awning in cm
awning
in cm
200 - 250
251 - 300
301 - 350
351 - 400
401 - 450
451 - 500
501 - 550
551 - 600
151)
40
40
40
60
702)
90
90
–1)
15
40
40
60
702)
90
90
–
–1)
15
40
60
702)
90
90
–
–
–1)
15
40
40
902)
902)
–
–
–
–
–1)
15
40
65
150 200 250 300 350
–
–
–
–1)
15
40
652)
902)
400
TECHNIC AND DIMENSIONS
fabric width (width – 18 cm)
width
projection
Projection and measurement of center to center brackets
Brackets and joint arms (for installation on concrete)
Please note: Installation brackets should be fitted max. 10
cm away from arm bracket. For standard awnings the dimen-
sion A1 and A2 is the same. Support bracket should be pla-
ced in centre. Measurement of center to center brackets for
awnings with three and four joint arms on request. Special
measurement of center to center brackets for installation on
other substructure are optional possible. Please ask for form
sheet " measurement of center to center brackets " CLASSIC.
1) 1) minimum width of awning: if the awning is between
30 and 50 cm wider than the projection, then measurement
A1, A2 is between 8 and 14 cm.
2) For guide bar PRISMA the measurement A1,A2 is 50 cm
projection
bracket joint arm
arm bracket drop bar
width of number of number of
awning in cm brackets* joint arms
180 - 400
401 - 600
601 - 650
651 - 800
801 - 1200
2
3
3
4
6
2
2
3
4
4
AAddvviiccee: deviating to this overview, for some system widths with projec-
tions of 300/350/400 cm more installation brackets will be delivered.
Please see overview "extraction forces and bracket sets (K-set) for the
accurate number of brackets depending on the installation substructure.

T1-35
Subject to technical changes, edition 03.2008
INSULATED PLASTER SYSTEMS
MHZ carrier bar awning CLASSIC
The information for the insulated plaster systems are also valid for MHZ awnings VEGAS,VENUS and NOVA. On request, we cal-
culate the current extraction forces depending on the needed bracket sets (K-set) for you.
For this we need following details:
- type of awning inclusive accessory (e.g. Vertima)
- installation type
- substructure of installation
- thickness of insulated plaster, as well as selected insulated plaster system (S1/S2/S3)
plaster up to 2 cm thickness
wall installation
(without spacer)
ceiling installation
(without spacer)
plaster (without insulation)
insulated plaster up to 8 cm thickness
wall installation
spacer with PVC-tube
ceiling installation
spacer with PVC-tube
ø 40 mm
ø 15
Insulated plaster -
System S1
Insulated plaster -
System S3
Insulated plaster -
System S2
insulated plaster up to 16 cm thickness
wall installation
spacer using plastic distance
plates
ceiling installation
spacer using plastic distance
plates
not possible
190 mm
220 mm
10
extraction forces on request, depen-
ding on installation substructure and
thickness of insulated plaster, as well
as insulated plaster system.
extraction forces on request, depen-
ding on installation substructure and
thickness of insulated plaster, as well
as insulated plaster system.
insulated plaster up to 17 cm thickness
wall installation
spacer using Thermax M16
ceiling installation
spacer using Thermax M16
not possible
extraction forces on request, depen-
ding on installation substructure and
thickness of insulated plaster, as well
as insulated plaster system.
please see extraction forces index,
depending on installation substructure.

MHZ carrier bar awning
CLASSIC
T1-36
Subject to technical changes, edition 03.2008
WALL BRACKET SET (K-SET)
wall brackets
It is possible to install the brackets outside or inside the arm brackets. Pairs of brackets have to be installed on the left and right side of the arm bracket. Consider
the measurement of center to center brackets! For width of 401 cm on and 2 arms an additional support bracket will be needed. * From width 601 cm an additional
third arm in left or right version will be needed. ** Special bracket set for projection of 400 cm
WK 1
K-Set TA (standard)
2 units WK 1
total 4 fixation points
K-Set TB* (standard)
3 units WK 1
total 6 fixation points
Advise to DIN EN 13561
The standard delivered brackets are for installation on
concrete C20/25. Due to static reasons, it is mandatory
to advise with the order, if there is an other installation
substructure, or installation on insulated plaster, then it
is necessary to use different brackets, respectively other
accessories (additional charge).
60
20
84
150 mm
96
wall bracket WK 1
standard wall brackets
2 fixation points per bracket
200 mm
150
230 mm
150
60
22
25
wall bracket WK 2
VEGAS wall bracket (WK 8)
with adapter (additional charge)
4 fixation points per bracket
340 mm
300 mm
350 mm
28050
12
20
130
12
350 mm
280
50
WK4 WK5
wall bracket WK 4/5
wall bracket (WK 1) with additional steel plate
(add. charge)
WK 4: 6 fixation points per bracket
WK 5: 2 fixation points per bracket
wall installation
80-100 mm
80-100 mm
80-100 mm
80-100 mm
WK 2
K-Set TF (additional charge)
2 units WK 2
total 8 fixation points
K-Set TH* (additional charge)
3 units WK 2
total 12 fixation points
80-100 mm 80-100 mm
80-100 mm 80-100 mm
160-200 mm160-200 mm
160-200 mm160-200 mm
160-200 mm 160-200 mm
160-200 mm
K-Set TC (standard)
4 units WK 1
total 8 fixation points
K-Set TD/TD4** (standard)
5 units WK 1
total 10 fixation points
K-Set TE* (standard)
6 units WK 1
total 12 fixation points
80-100 mm 80-100 mm
80-100 mm 80-100 mm
80-100 mm 80-100 mm
WK 4
K-Set TI (additional charge)
2 units WK 4
total 12 fixation points
K-Set TK (additional charge)
2 units WK 4
1 units WK 5 (in center)
total 14 fixation points
K-Set TL* (additional charge)
3 units WK 4
total 18 fixation points
WK 5
K-set = bracket set; WK = wall bracket; DK = ceiling bracket

In order that the wind resistance categories which are stated by us holds the validity, the fastener of the assembler has to match with
the substructure. For incoming orders without details of installation substructure you will receive brackets for the installation on con-
crete C20/25. Please keep in mind, that these brackets are possibly not usable for other substructure. To fulfil the DIN EN 13561 it is
essential to install the kind and number of brackets which are recommended per product. Thereby you have to consider absolutely
the determined dowel extraction forces, as well as the installation and mounting references of the producer of fastener (inclusive
edge distance). Accurate extraction forces depending to thickness of insulated plaster and the demanded bracket set, as well as
installation on other substructure, on request (please also see column insulated plaster systems on page T1-35).
CCoouupplleeddssyysstteemmssare calculated as two single systems (system width = ½ total width). The bracket set (K-set) will be needed twice.
EXTRACTION FORCES AND BRACKET SETS for wind resistance category 2
Extraction forces in Newton (N) per installation screw
MHZ carrier bar awning
CLASSIC
T1-37
Subject to technical changes, edition 03.2008
N = extraction force in Newton (N) per installation screw; K-set = intended bracket set
Advice: the above mentioned extraction forces are also effective for application of guide bar PRISMA.
CLASSIC/CLASSIC without VERTIMA CLASSIC/CLASSIC with VERTIMA
wall installation on concrete C20/25 wall installation on concrete C20/25
width
projection in cm
width
projection in cm
width
projection in cm
width
projection in cm
width
projection in cm
width
projection in cm
width
projection in cm
width
projection in cm
wall installation on brick > MZ 12 wall installation on brick >= MZ 12
wall installation on vertically perforated brick > HLZ 12 wall installation on vertically perforated brick > HLZ 12
wall installation on gas concrete > PB 2 wall installation on gas concrete > PB 2

T1-38
Subject to technical changes, edition 03.2008
MHZ carrier bar awning
CLASSIC
CEILING BRACKET SET (K-SET)
ceiling brackets
225 mm
85 49
96
60
85
37
154 mm
ceiling bracket DK 1
standard ceiling bracket
(additional charge ceiling)
2 fixation points per bracket
175 mm
135
20
203 mm
20
175
ceiling bracket DK 2
standard ceiling bracket (DK 3)
with adapter (additional charge)
4 fixation points per bracket
ceiling installation
K-set = bracket set; WK = wall bracket; DK = ceiling bracket
Advise to DIN EN 13561
The standard delivered brackets are for installation on
concrete C20/25. Due to static reasons, it is mandatory
to advise with the order, if there is an other installation
substructure, or installation on insulated plaster, then it
is necessary to use different brackets, respectively other
accessories (additional charge).
DK 1
K-Set TM (add. charge ceiling)
2 units DK 1
total 4 fixation points
K-Set TN (add. charge ceiling)
3 units DK 1
total 6 fixation points
80-100 mm 80-100 mm
80-100 mm 80-100 mm
DK 2
K-Set TS (additional charge)
2 units DK 2
total 8 fixation points
K-Set TT* (additional charge)
3 units DK 2
total 12 fixation points
80-100 mm 80-100 mm
80-100 mm 80-100 mm
160-200 mm 160-200 mm
160-200 mm 160-200 mm
160-200 mm 160-200 mm160-200 mm
K-Set TO ((add. charge ceiling)
4 units DK 1
total 8 fixation points
K-Set TP (add. charge ceiling)
5 units DK 1
total 10 fixation points
K-Set TR* (add. charge ceiling)
6 units DK 1
total 12 fixation points
It is possible to install the brackets left or right of the arm brackets. Pairs of brackets have to be installed on the left and right side of the arm bracket. Consider the
measurement of center to center brackets! From width of 401 cm on and 2 arms an additional support bracket will be needed.
* From width 601 cm on an additional third arm in left or right version will be needed.
** special bracket set for projection of 400 cm
K-Set TU4** (additional charge)
2 units DK 4
1 unit DK 5 (in center)
Total 8 fixation points
DK4 DK5
80-100 mm 80-100 mm
DK 4 DK 5
175 mm
135
20
203 mm
20
175
340 mm
300
20
203 mm
20
175
135
DK4 DK5
ceiling bracket DK 4/5
ceiling bracket (DK 4)
with adapter (additional charge)
4 fixation points per bracket

In order that the wind resistance categories which are stated by us holds the validity, the fastener of the assembler has to match with
the substructure. For incoming orders without details of installation substructure you will receive brackets for the installation on con-
crete C20/25. Please keep in mind, that these brackets are possibly not usable for other substructure. To fulfil the DIN EN 13561 it is
essential to install the kind and number of brackets which are recommended per product. Thereby you have to consider absolutely
the determined dowel extraction forces, as well as the installation and mounting references of the producer of fastener (inclusive ed-
ge distance). Accurate extraction forces depending to thickness of insulated plaster and the demanded bracket set, as well as in-
stallation on other substructure, on request (please also see column insulated plaster systems on page T1-35).
CCoouupplleeddssyysstteemmssare calculated as two single systems (system width = ½ total width). The bracket set (K-set) will be needed twice.
EXTRACTION FORCES AND BRACKET SETS for wind resistance category 2
Extraction forces in Newton (N) per installation screw
MHZ carrier bar awning
CLASSIC
T1-39
Subject to technical changes, edition 03.2008
N = extraction force in Newton (N) per installation screw; K-set = intended bracket set
Advice: the above mentioned extraction forces are also effective for application of guide bar PRISMA.
Advise for rafter installation: for width up to 400 cm two brackets and width up to 650 cm 3 brackets will be used (for wind resistance
category 0).
ceiling installation on concrete C20/25 ceiling installation on concrete C20/25
width
projection in cm
width
projection in cm
CLASSIC/CLASSIC without VERTIMA CLASSIC/CLASSIC with VERTIMA
Other manuals for CLASSIC
1
Table of contents
Popular Accessories manuals by other brands

Boothroyd Stuart Meridian
Boothroyd Stuart Meridian 101 operating instructions

Dusun
Dusun Smart Plug EU Product specification

Chaney Instrument
Chaney Instrument AcuRite 06045 instruction manual

sun control
sun control TUCSON XL Use and maintenance

Swann
Swann SWADS-WVDP720-UK quick start guide

Gira
Gira 0551 4 Series installation instructions