Microlectra SABRE Series User manual

SSAABBRREE SSeerriieess
DS-SABRE-L-3
Description
WhateveryourswitchingapplicaontheSBRERemotecontrolsystemwith4
individuallycontrolledrelayswitchesandacompletelywaterproofIP68enclosure
SBREwillbeagreatchoice.
TheSBREremotecontrolsystemhasbeendesignedwiththerequirementsof
Industrialelectriciansinmindandthereforeitcanbeusedtoswitchalldomesc
lighngtypesaswellasforindustrialapplicaonssuchasoodlights,electricgates
andconveyorsorloadingbins.
Eachreceiverhas4switchedoutputs,whichusing
ouronetouch‘easy-learn’processcanbecontrolled
fromanyswitchonanycompabletransmier.
Thankstothelatesttechnologyeachofthe4
outputsontheSBREremotecontrol
systemcanbesettooperateinamed,
momentaryorlatchingmodeforcomplete
exibility.
Features
4switchrelays-1200Weach
Upto4000mRange
12-32Vac/dcand230Vacsupply
CompletelywaterproofBS
enclosure(IP68)
lloutputsmomentary,latching
orprogrammablemed
nyswitchmapstoanyrelayor
mulplerelays
868MHzReliableFMTechnology
EMCCompliantforEurope
RUGGEDREMOTECONTROLSYSTEM
Applications
Remote outdoor
switching
Industrial control
Conveyors
Plant equipment
www.microlectra.nl
www.microlectra.nl [email protected]

SSAABBRREE RReemmoottee ccoonnttrrooll
DS-SABRE-L-3 PAGE 2
SystemPartNumbering
ddionalReceiver
Part Number Description Receiver
Power Supply
Range**
(Metres)
ELITE-RXL Receiver 4 outputs 230Vac
12-32Vac/dc 4000m
**Rangestatedisopmum-LineofSight.
Rangecanbedramacallyreducedbyobstaclesandotherinterference.
ddionalTransmiers
SBREtransmiersareavailableindividuallywith1,3,4or8buonsandcanbeconguredtoworkany
SBREorELITEseriesreceiver
PartNumber Descripon
SBRE-T1 Transmier1switch
SBRE-T3 Transmier3switch
SBRE-T4 Transmier4switch
SBRE-T8 Transmier8switch
Part Number Description Receiver
Power Supply
Range**
(Metres)
SABRE-S4L System 4 outputs
With SABRE-T4
230Vac
12-32Vac/dc 4000m
Microlectra bv.
www.microlectra.nl

SSAABBRREE RReemmoottee ccoonnttrrooll
DS-SABRE-L-3 PAGE 3
RELAY 1 RELAY 2 RELAY 3 RELAY 4
FUSE
POWER
TIMER
Timer Select Button –Used to select timer mode
Erase Button –Press and hold to erase all pairings, see
advanced operation for individual erase
Signal Test mode –Press to enter signal test mode
Sync/Pair Button –Press once to auto sync. See
Advanced operation for other pairing options.
Momentary or Latching selection –Make the link to select
momentary operation break the link for latching operation.
230Vac power
input
Power input fuse –should be 500mA
Relay switch terminals:
Common
Normally Open
Normally Closed
RELAY 1
RELAY 2
RELAY 3
RELAY 4
SYNC
TEST
ERASE
Status LEDs–Flash when
signals are sent/received
L N E
8
7
6
5
4
3
2
1
Mag sync –Touch a
magnet to the plastic
case in the cross
hatched area to
replicate the sync
button on board
without opening the
case
0Vdc
12-32Vdc
NO COM NC NO COM NC NO COM NC NO COM NC
CONNECT EITHER
230Vac OR 12-32Vdc
NEVER BOTH
Microlectra bv.
www.microlectra.nl

SSAABBRREE RReemmoottee ccoonnttrrooll
DS-SABRE-L-3 PAGE 4
Quick Installation Guide (systems only)
The SABRE system provides 4 switches each capable of switching up to 1.2KW (5A @ 230V). Each relay is
independent and separately controlled. The SABRE L series remote control system provides switched contacts
and can therefore be used to switch most voltages either AC or DC (see maximums on page 7)
1. First mount the SABRE system receiver box in the wall in your desired location (see Page 8 for wall
mounting dimensions and information).
2. Open the enclosure by removing fixing screws from the enclosure front and then removing the front
from the enclosure.
3. Wire either MAINS, Live, Neutral and Earth connections to the power supply screw terminal as shown
below (shown as A). Or wire 12-32Vac or 12-32Vdc to the low voltage terminals. (shown as B)
4. Wire your desired connections to the relay switches (shown as C)
5. Once all required wiring is complete, use the handheld SABRE transmitter to switch the outputs on and
off.
6. As supplied, the handheld will operate the outputs - Button 1 to output 1, Button 2 to output 2 etc.
7. All buttons will operate in a latching mode - Press for on, press again for off. It is possible to change the
operation to momentary mode by fitting the links (shown as D)
8. For advanced operation such as adding extra transmitters, different button mapping options see
advanced operation section.
FFiigg 11..11
RELAY 1 RELAY 3 RELAY 4
FUSE
POWER
TIMER
RELAY 1
RELAY 2
RELAY 3
RELAY 4
SYNC
TEST
ERASE
L N E
8
7
6
5
4
3
2
1
0Vdc
12-32Vac/dc
NO COM NC NO COM NC NO COM NC NO COM NC
CONNECT EITHER
230Vac OR 12-32Vac/dc
NEVER BOTH
230V INPUT
SUPPLY A
C
D
B
Microlectra bv.
www.microlectra.nl

SSAABBRREE RReemmoottee ccoonnttrrooll
DS-SABRE-L-3 PAGE 5
Advanced operation
The SABRE system comes with one transmitter, this is already ‘SYNCed’ and will
operate the system out of the box.
To AUTO-SNYC a new transmitter
1. To SYNC a new SABRE handheld transmitter to the receiver box - simply press the SNYC button on the
ELITE receiver board. (see page 3 for button locations)
2. The ELITE receiver will flash all of its relay output LEDs at a high rate to show that it is ready for AUTO
-SYNC.
3. Press ANY button on the transmitter handheld that you wish to SNYC to the receiver.
4. All flashing LEDs will go out, the SYNC LED will flash quickly for 2 seconds then go out.
5. The ELITE receiver will then exit SYNC mode and return to normal operating mode - you may now use
the transmitter to switch the outputs.
NOTE: Maximum 31 handhelds can be auto sync’ed.
MANUAL-SYNC individual transmitter buttons (advanced)
1. To SYNC a specific SABRE handheld transmitter button to a specific output on the ELITE receiver box -
press the SNYC button on the ELITE receiver board. (see page 3 for button locations).
2. The ELITE receiver will flash all its relay output LEDs at a high rate to show that it is ready for SYNC.
3. Press the SYNC button again - the ELITE receiver will flash output LED 1 only - this is showing that out-
put 1 is selected. Pressing the SYNC button again will select output 2 and so on, through to output 4.
4. Once you have selected the required output (that output LED only is flashing) press the SPECIFIC
button on the transmitter handheld that you wish to SNYC to the receiver.
5. The flashing LEDs will go out, the SYNC LED will flash quickly for 2 seconds then go out.
NOTE: After a successful pairing the ELITE-RXL will exit SYNC mode automatically.
You cannot perform a SYNC ALL and a MANUAL SYNC on a single transmitter.
Maximum of 31 BUTTONS can be auto sync’ed
Erasing ALL transmitters:
1. Open the case and apply power
2. Press and hold the ERASE button for 10 seconds
3. All relay LEDs flash together and then go out
4. Erase complete, you can now follow the pairing process to pair your transmitters to the receiver.
ERASE Individual Transmitters:
1. Open the case and apply power
2. Press and release the ERASE button
3. The LED next to ERASE should remain lit and all relay LEDs will be flashing
4. Press any button on the transmitter to be erased
5. All output LEDs will go out to show that the transmitter has been erased
6. The ELITE will exit to normal operating mode
Setting MOMENTARY / LATCHING links
It is possible to set the relay switches on the ELITE receiver to either momentary or latching operation
(Latching - one press for on, one press for off, Momentary - On while button is held only)
1. The Momentary/Latching Setting links are in the position shown as (D) on page 4.
2. To set a relay switch to momentary choose the associated link cap:
Link fitted - MOMENTARY
Link Removed - LATCHING
4. Re-apply the power to the ELITE-RXL.
Continued overleaf...
Microlectra bv.
www.microlectra.nl

SSAABBRREE RReemmoottee ccoonnttrrooll
DS-SABRE-L-3 PAGE 6
0 LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 LED 7 LED 8 LED
0s ½ s 5s 10s 30s 1m 10m 30m 1hr
Advanced operation continued…
TEST MODE
The ELITE Receiver comes with an in-built test mode which allows a user to check the signal strength of any
compatible handheld:
1. Press the TEST button on the PCB (see page 3 for button locations)
2. Press any button/activate the transmitter which you want to test
3. LEDs 1-8 will show a bar graph of the signal strength - the more LEDs on the better the signal
TIP: Try the transmitter in the location where it will be used to make sure it will work once installation is com-
plete.
Note: When in test mode and paired transmitter will still activate its relay.
For reliable communications please ensure at least 3 LED’s are lit.
TIMER SELECT MODE
The ELITE Receiver has a timer option which can be set individually on each output. Meaning that you can set
any output to de-activate after a different amount of time should you wish
1. To enter timer select mode - Press the TIMER button
2. Select your chosen output by pressing the TIMER button to scroll through each relay in turn
3. When the LED for the required output is flashing wait until it becomes solidly LIT
4. Press the TIMER button again to increase the timer delay in line with the table below
5. When you have selected the required delay, wait 3 seconds. The Red TIMER LED will flash to show that
the setting is saved
Note: Settings are saved even after power is removed.
As default all timers are set to 0 seconds.
NOTE: When zero LED’s are lit the relays will operate as per the jumper links. Momentary or latching
As default all relay switches are latching.
TIMERS in MOMENTARY/LATCHING
1. When a relay is set to MOMENTARY a timer will restart it’s count down each time a button is pressed.
2. When a relay is set to LATCHING the relay will turn ON/OFF on each button press and the timer will
count down will start when a relay is left in the ON position, dropping the relay after the timer period
expires.
Erasing ALL Timers:
1. Open the case and apply power
2. Press and hold the TIMER button for 10 seconds,
3. A single relay LED will be flashing
4. When all Relay LED flash together and then go out the timer erase process is complete.
5. All relays will operate as per their jumper settings.
Microlectra bv.
www.microlectra.nl

SSAABBRREE RReemmoottee ccoonnttrrooll
DS-SABRE-L-3 PAGE 7
Technical Specifications
Transmitters: SABRE-Tn Transmitters
Enclosure Rating: IP68
Battery Type: AAA x 4 (supplied)
Battery Life: 3 years @ approx 100 x 1/2second presses per 3 day.
Dimensions: 154 x 85 x 48 mm
Storage Temperature: -10 to +70o Celsius.
Operating Temperature: -10 to +50o Celsius
Changing the battery:
1. Un screw the 6 fixing screws on the rear of the enclosure.
2. Carefully separate the two enclosure halves - as the wires connecting them and should not be strained.
3. Remove the front half of the enclosure (joint is on top of the red rubberised section.
4. The batteries are fixed into the base - replace with new.
5. Re-assemble.
Receiver Decoder: ELITE-RXL
Enclosure Rating: IP68
Dimensions: 267 x 148 x 78 mm (not including antenna)
Storage Temperature: -10 to +70o Celsius.
Operating Temperature: -10 to +50o Celsius.
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
Approvals Information:
All RF Solutions products are manufactured in accordance with our ISO:9001 Quality System
SABRE Systems are manufactured to CE standards
Further information available on request.
Electrical Characteristics Min Typical Max Units
Supply Voltage 6 6 V
Frequency: 869.500 MHz
RF Output Power (ERP) @ 869.5MHz - 100 mW
ELECTRICAL CHARACTERISTICS MIN TYPICAL MAX DIMENSION
Supply Voltage for MAINS 230Vac +10% Vac
Supply voltage for LOW VOLTAGE 12V 24 32V Vac/Vdc
Relay Rating* (230Vac) RLY1-4 6 12A
(peak)
A(rms)
Supply Current : Quiescent
All relays operating*
60
170
30
120
25
90 mA
Time delay from Tx on Switch to Rx Relay operation 30 mS
Time delay from Tx sw relax to Rx Relay release 30 mS
Microlectra bv.
www.microlectra.nl

SSAABBRREE RReemmoottee ccoonnttrrooll
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd.
assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is
not authorised except with express written approval from R.F.Solutions Ltd.
RF Solutions Ltd. Recycling Notice
Meets the following EC Directives:
DO NOT
Discard with normal waste, please recycle.
ROHS Directive 2002/95/EC
Specifies certain limits for hazardous substances.
WEEE Directive 2002/96/EC
Waste electrical & electronic equipment. This product must be
disposed of through a licensed WEEE collection point. RF Solu-
tions Ltd., fulfills its WEEE obligations by membership of an
approved compliance scheme.
251.00
All Dimensions in mm
106.00
53.00
125.50
Wall Mounting Dimensions (not to scale)
Waste Batteries and Accumulators
Directive 2006/66/EC
Where batteries are fitted, before recycling the
product, the batteries must be
removed and disposed of at a licensed
collection point.
Environment Agency producer registration num-
ber: WEE/JB0104WV.
Microlectra bv.
Microlectra bv.
Hermanus Boerhaavestraat 6. 3261 ME Oud-Beijerland. Netherlands.
Tel 31(0)186-616290 Fax 31(0)186-610349 www.microlectra.nl [email protected]
Table of contents