Microsens MS657023X User manual

Quick Installation Guide –MS657023X
©2019 MICROSENS GmbH & Co. KG –Hamm/Germany www.microsens.com V1.0-1943-SH
Hardware Introduction
The Industrial Gigabit Ethernet VDSL2 Extender MS657023X
allows the transmission of Gigabit Ethernet data over simple
twisted-pair lines. Therefore Ethernet signals are converted
into VDSL2 signals and vice versa. The extender is used per
pair. One device has to be configured as master, the other
one as remote unit. The data rate depends on the transmis-
sion distance and the quality of the cable.
Bottom Interface
On the bottom side the following interfaces are placed:
RJ-45 connector for 10/100/1000Base-T Ethernet
RJ-45 connector for VDSL2
LEDs for Ethernet, VDSL and power
DIP switch for easy configuration
Both RJ-45 ports are intended for the use of shielded and
unshielded cables.
LAN Port
The device is equipped with a 10/100/1000Base-T Ethernet
port with RJ-45 connector which supports auto-negotiation
and auto-crossing.
VDSL2 Port
For the VDSL interface a RJ-45 connector is used too. But
only pin 4 and 5 are used. Therefore a RJ-11 could be used
instead. However the use of high quality RJ-45 connectors is
recommended. For 2-wire lines Microsens offers a RJ-45
adapter with screw terminal. This adapter eliminates the
need of crimped connector.
LED Interface
An extended LED interface gives detailed information about
the device status. Their color is always green.
PWR LED
A static green LED indicates that the device is powered.
VDSL LEDs
RT LED: The RT LED indicates the configured device mode.
“ON” means that the device is configured as remote unit.
LNK LED: This LED informs about the VDSL link. The LED is
on if a valid link is established. Slow blinking indicates that
the device is in learning mode. Fast blinking indicates data
transmission. The learning mode should be finished after
around 90 seconds. Otherwise the connection should be
checked.
LEDs for Ethernet Port
For the Ethernet port 3 LEDs are used. They are indicating
link speed and data transmission. Only the LED for the es-
tablished link speed is on. Blinking indicates data transmis-
sion.
DIP Switch
DIP
Sw.
Configuration
D1: Off
D2: Off
D3: Off
D4: Off
Role
Master
Mode
G.INP
Target SNR Margin
8 dB
Max. Data Rate DS/US
160/160 Mbps
D1: Off
D2: On
D3: Off
D4: Off
Role
Master
Mode
G.INP
Target SNR Margin
8 dB
Max. Data Rate DS/US
220/110 Mbps
D1: Off
D2: Off
D3: On
D4: Off
Role
Master
Mode
Interleaved
Target SNR Margin
6 dB
Max. Data Rate DS/US
160/160 Mbps
D1: Off
D2: On
D3: On
D4: Off
Role
Master
Mode
Interleaved
Target SNR Margin
6 dB
Max. Data Rate DS/US
220/110 Mbps
D1: Off
D2: Off
D3: Off
D4: On
Role
Master
Mode
G.INP
Target SNR Margin
12 dB
Max. Data Rate DS/US
150/150 Mbps
D1: Off
D2: On
D3: Off
D4: On
Role
Master
Mode
G.INP
Target SNR Margin
12 dB
Max. Data Rate DS/US
220/110 Mbps
D1: Off
D2: Off
D3: On
D4: On
Role
Master
Mode
G.INP
Target SNR Margin
24 dB
Max. Data Rate DS/US
20/20 Mbps
D1: Off
D2: On
D3: On
D4: On
Role
Master
Mode
Interleaved
Target SNR Margin
6 dB
Max. Data Rate DS/US
150/50 Mbps
D1: On
D2: -
D3: -
D4: -
Remote Unit (RT) will always follow the setting
of Master Unit (OT). When the unit operates in
RT Mode, DIP switches 2, 3 and 4 have no func-
tions.
Power Interface / Earth Terminal
On the top side, the earth terminal (M4 screw) and the power
interface with screw terminal plug are placed. Connect the
earth terminal to the protective earthing conductor of the
buildings installation.
The power interface supports 12 and 24 VDC input voltages.
Insert the positive and negative wires into V+ and V- contact
on the terminal block and tighten the wire-clamp screws to
prevent the wires from being loosened. The total power con-
sumption is approximately 4.5 W.

Quick Installation Guide –MS657023X
©2019 MICROSENS GmbH & Co. KG –Hamm/Germany www.microsens.com V1.0-1943-SH
Please consider the following wiring requirements:
Wire range: 0.5 mm² to 2.5 mm²
Solid wire (AWG): 12-24
Stranded wire (AWG): 12-24
Torque: 5 lb-In / 0.5 Nm / 0.56 Nm
Wire Strip length: 7-8 mm
Max wire length: 3m (9.84 ft)
WARNING: Any exceeded input voltage will not make this
unit function and may damage this unit.
WARNING: Always ground the power source to maintain a
clean power input.
Installation
DIN-rail Mounting
The device is intended for DIN-rail mounting. The DIN-rail
adapter is placed at the rear side.
Mounting Steps
STEP 1: Hook the unit over the DIN rail. If the VDSL interface
is used for the connection between two buildings, all neces-
sary protective measures must be ensured externally.
STEP 2: Push the bottom of the unit towards the DIN-rail
until it snaps into place.
Removal Steps
STEP 1: Push the unit down to free the bottom of the DIN-
rail.
STEP 2: Rotate the bottom of the unit away from the DIN-
rail.
STEP 3: Unhook top of unit from DIN-rail.
Wall Mounting
For wall-mounting the DIN-rail adapter must be removed. At
the rear side, two mounting holes are placed which can be
used for horizontal or vertical wall-mounting.
Installation Procedure
STEP 1: Configure both GBE (Gigabit Ethernet) extenders by
using the DIP switch. For point-to-point applications, one unit
must be configured as master (OT) and the other one as
slave (RT).
STEP 2: Connect the device to earth.
STEP 3: Connect the GBE extender configured as slave with
a regular cat. 5 cable to the LAN (Local Area Network).
STEP 4: Power on the GBE extender by connecting the power
terminal.
STEP 5: Connect both GBE extenders via the VDSL port.
STEP 6: Connect the LAN port of the second GBE extender
(master) with a regular cat. 5 cable.
STEP 7: Power on the second GBE extender
Precautions and
Safety Warnings
Disconnect all power from devices before attempting in-
stallation!
This device is intended for installation only in re-
stricted access locations as defined where both these
conditions apply:
oAccess is through the use of a lock or tool and
key, or other means of security, and is controlled
by the authority responsible for the location.
oAccess can only be gained by service persons or
by users who have been instructed about the
reasons for the restrictions applied to the loca-
tion and about any precautions that shall be
taken.
All electric installations must be carried out in accord-
ance with local and national regulations.
Do not work on the system, connect or disconnect ca-
bles during periods of lightning activity.
The equipment must be connected to earth.
Shield of RJ-45 cables has to be connected to the same
earth potential as the equipment.
If the VDSL interface is used for the connection between
two buildings, all necessary protective measures must
be ensured externally.
This equipment relies on the building’s installation for
short-circuit (overcurrent) protection. Ensure that a
fuse or circuit breaker no larger than 1 A is used.
Table of contents
Other Microsens Extender manuals
Popular Extender manuals by other brands

Patton
Patton CopperLink CL2300 quick start guide

Extreme USB
Extreme USB USB 3.0 SP3022 quick start guide

StarTech.com
StarTech.com SV565UTPUSA user manual

KVM-TEC
KVM-TEC masterEASY Quick instructions

Avenview
Avenview VGA-C5ARS-SET user guide

Honeywell
Honeywell Farenhyt ECS-CE4 Product installation document