Midaswei MW-05A DUAL User manual

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
1
A. Overview
Introduction:
Power switch
Ion quantity
adjustment switch
Power supply indicator
High voltage
abnormality indicator
High voltage normality
indicator
Ion quantity indicator
Fan speed adjuster

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
2
B. Operating instructions
MW-05A DUAL is an Ionizer with two MW-05A ionizer fans, it has independent
five-stage adjustable ions quantity, independent Adjustable air volume and an
independent protection of high voltage output abnormal. By using with the accessory
AC adapter, MW-05A DUAL is suitable for 110Vac/220Vac supply voltage.
1. AC adapter installation
Please connect the plug of the accessory AC Adapter with 110Vac/220Vac power
outlet, connect with Y-type DC cable and insert Y-type DC cable plug into the DC IN
connector on the back of ionizer fan. Note: do NOT use non- accessory AC adapters.
2. Operation
MW-05A DUAL is an Ionizer with two MW-05A ionizer fans, it has sequentially
five-stage adjustable ions quantity and adjustable air volume, the two ionizer fans are
independent operation. The single fan operation rule is as follows:
2.1 Initial Stage
Turn the power switch ON, and the fan spins up. ‘POWER’LED and
‘H.V.’LED become light up. The ion number is zero in initial stage.
2.2 First stage
Push the ion quantity adjustment switch (ION ADJ) in the initial stage, MW-05A
DUAL will enter into first stage. The fan keeps spinning and the buzzer will beep
once. The ‘POWER’LED,‘H.V.’LED and four LEDs of ion quantity indicator
become light up. The generated ion number is largest in first stage.
2.3 Second stage
Push the ion quantity adjustment switch (ION ADJ) in the first stage, MW-05A
DUAL will enter into second stage. The fan keeps spinning and the buzzer will beep
once. The ‘POWER’LED,‘H.V.’LED and right-hand side three LEDs of ion
quantity indicator become light up. The generated ion number is secondly large in
second stage.

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
3
2.4 Third stage
Push the ion quantity adjustment switch (ION ADJ) in the second stage,
MW-05A DUAL will enter into second stage. The fan keeps spinning and the buzzer
will beep once. The ‘POWER’LED,‘H.V.’LED and right-hand side two LEDs
of ion quantity indicator become light up. The generated ion number is medium in
third stage.
2.5 Fourth stage
Push the ion quantity adjustment switch (ION ADJ) in the third stage, MW-05A
DUAL will enter into fourth stage. The fan keeps spinning and the buzzer will beep
once. The ‘POWER’LED,‘H.V.’LED and rightmost LEDs of ion quantity
indicator become light up. The generated ion number is little in fourth stage.
2.6 Initial stage
Push the ion quantity adjustment switch (ION ADJ) in the fourth stage, MW-05A
DUAL will re-enter into initial stage. The fan keeps spinning and the buzzer will beep
once.
2.7 Air volume control
The FAN ADJ knob is fan speed control, turn the knob in a clockwise direction
can increase air volume, in a counterclockwise direction can decrease air volume, if
knob turn to end of the counterclockwise, the fan speed will operation in low speed
and minimum air volume.
Fan Speed
Knob indication
Application
Minimum Fan Speed
Thin wafer inspection, or
Re-work station
Standard Fan Speed
Wafer inspection, or
Re-work station
Maximum Fan Speed
Wafer inspection,
Reel taping,
EFEM

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
4
3. Abnormal condition
3.1 When the output high voltage is abnormal, such as the internal cable has poor
connection or the discharge needle unit does not discharge, the ‘ALARM’LED
becomes light up and the buzzer sounds. If this abnormal condition is not solved
within 1 minute, MW-05A DUAL will be locked.
3.2 When the foreign object contacts the discharge needle unit, ‘ALARM’LED
becomes light up and the buzzer sounds. If this abnormal condition is not solved
within 1 minute, MW-05A DUAL will be also locked.
3.3 Holding the ion quantity adjustment switch (ION ADJ), the buzzer sounds until
release the ion quantity adjustment switch.
4. Indication/Function
Stage
Ion quantity
LED indication
Fan
Buzzer
Power ON
(Initial stage)
zero
Operation
Stop
1st stage
Largest
Operation
Beep
2nd stage
Secondly large
Operation
Beep
3rd stage
Medium
Operation
Beep
4th stage
Little
Operation
Beep
Hold ION ADJ
Keep original state
Operation
Raise
alarm
High voltage
abnormality
Operation
Raise
alarm
1 2 3 4
A
B
C
D
4321
D
C
B
APOWER
ALARM
H.V
1 2 3 4
A
B
C
D
4321
D
C
B
APOWER
ALARM
H.V
1 2 3 4
A
B
C
D
4321
D
C
B
APOWER
ALARM
H.V
1 2 3 4
A
B
C
D
4321
D
C
B
APOWER
ALARM
H.V
1 2 3 4
A
B
C
D
4321
D
C
B
APOWER
ALARM
H.V
1 2 3 4
A
B
C
D
4321
D
C
B
APOWER
ALARM
H.V

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
5
C. Cleaning and Maintenance
1. 1. Clean the discharge needle by a soft brush at least once a week. Do NOT clean
the discharge needle by any hard object, or the needle tip will be damaged.
2. If the needle tip is damaged, replace the discharge needle unit immediately to
maintain proper function.
3. The discharge needle may have carbon deposits and consumption due to corona
effect. It is recommended to replace the discharge needle unit every 3 months or
when the static elimination performance is degraded.
4. Clean both side louvers by a soft brush or compressed air at least once a week.
If the filter is used, the filter cotton should be cleaned or replaced per month.
CAUTION:
* You should always turn OFF the power before maintaining the ionizer fan.
* The needle tip is very sharp. Pay attention to avoid being stabbed.

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
6
D. Specification
Name
MW-05A DUAL
Power supply voltage
Accessory AC adapter:
Input: 100Vac~240Vac, Output: DC24V
Input power
24W
High voltage output
AC 4400V
Static charge removal time
±1KV→±100V within 1 sec at distance of 30cm
central position
Balance Voltage
±2V at 30cm central position
Maximum Air flow
5.68 m3/min
Quantity of produced ozone
0.05ppm or less (testing distance 30cm)
Ambient temperature
0~40℃
Ambient humidity
15~65%RH (No condensation)
Dimension
398(L)×87(W)×197(H)mm (including protruding
portion)
Weight
2700g approx. (including stand)
Noise
50dB(A) @1m/maximum air volume.
Accessory
Instruction manual, AC Adapter and power cable,
1 to 2 output Y-type DC cable, MW-350 stand
Note: Testing instrument is Kleinwachter EFM-022, Performance may be degraded,
depending on working conditions and surrounding environment.

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
7
E. Dimensions
Unit: mm

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
8
F. Safety Precaution
1. Please read the instruction manual before installation.
2. Both side louvers cannot be blocked or inserted by any foreign object.
3. Do NOT use any non-accessories AC adapter.
4. Do NOT use the ionizer fan in a flammable or explosive environment.
5. Do NOT replace any part or attempt to self-repair.
6. Under normal use and proper care, we provide one-year warranty for MW-05A
Dual. However, consumables (discharge needles, filter cotton, etc.) are NOT
within warranty.
7. Must use genuine discharge needle hub or discharge needle, or unpredictable
dangers may occur.
8. When the ionizer fan is working, it generates a high voltage. Do not use it when
each louver is taken off.
9. The ionizer fan generates ozone in operation. Ventilation is required when
operating in a confined space.
10. Midaswei ionizer fan is designed for general industrial and indoor use. They are
not suitable for outdoor use as well as not suitable for environments that cause
life or property safety, such as nuclear power plants, aircrafts, ships or hospitals.
11. Avoid operating the ionizer fan in the following locations: locations with soot,
dust, flammable substances, acid-base solvent or gas, vibration, impact, strong
magnetism, strong electric fields, and drastic changes in temperature.

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
9
G. Set-up Pin-base of MW-05A DUAL
Step 1. Open fan cover
Step 2. Pick-up the screw and pin-base
Step 3. Replace the new pin-base and fix the screw
Step 4. Close fan cover
Open
Fixed point of pin-base
Pin-base
Screw
New pin-base
Fixed point of pin-base
Screw
Close
Close
Replace
Open
* The needle tip is very sharp. Pay attention to
avoid being stabbed.
* Do NOT hit or touch the needle tip, or the
needle tip may break.

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
10
H. Packaging
1. Each Ionizer set includes tow MW-05 A, a MW-350 Stand, a 1to2 output Y-type DC
cable, a Power adaptor and a Power cord.
2. Place an Ionizer set in the 470mm*140mm*250mm paper box。
3. 2 PCS 470mm*140mm*250mm paper box is 1 stack。
4. 497mm*337mm*293mm carton can be put into 2 paper box.
ITEM
NAME
Qty
pcs
01
MW-05A
2
2
02
POWER ADAPTOR & POWER CORD
1
1
03
MW-350 Stand
1
1
04
1 to 2 output Y- type DC cable
1
1
05
284*253*110 mm paper box
1
1
06
497*337*293mm carton
1
2

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
11
I. Attachment 1
1. The input voltage and current difference MW-05A DUAL and A vendor:
a. The Positive and negative voltage difference:
MW-05A DUAL △1V ;A vendor △1.2V。
b. The Positive and negative current difference:
MW-05A DUAL △7.6mA ;A vendor △44mA。
c. The angle difference:MW-05A DUAL No angle difference;A vendor 76°。
Fig1. MW-05A DUAL input voltage and current waveform
Fig2. A vendor input voltage and current waveform
+56.7V
-57.7V
+79mA
-86.6mA
-190mA
146mA
49.6V
48.4V
76°

Midaswei Trading Co., Ltd.
MW-05A Dual Rev:5
12
J. Attachment 2
The decay ability of MW-05 DUAL (measured on 2018/10/17).
This manual suits for next models
1
Table of contents
Other Midaswei Fan manuals