Midlite M2PJCTVW5 User manual

4 ½”
4 ¼”
TEMPLATE
2-GANG
RECESSED POCKET PLATE
ACTUAL SIZE
CUT ALONG THE DOTTED LINES
Instructions:
The Power Jumper™ IC is an easy to install power and cable relocation kit for your flat panel wall-mounted
display that provides power and conceals cabling behind the wall for a professional appearance.
Please read through the instructions before beginning the install. Follow Fig 1. on reverse side, as a
guide when installing.
1. Locate the studs near your display mount and check for any fire blocking.—NOTE: If you find a
horizontal stud, follow local guidelines on passing wiring through fire blocking.
2. Using the 2-gang paper template, select a location behind the display. Use a level to ensure the template is
placed correctly.
3. Trace around the template and cut the traced area out from the wall, creating hole (A).
4. To create hole (B), select a location below hole (A), but approximately 18” above the floor—NOTE: Keep
both 2-gang Pocket Plates less than 5’ apart to insure proper connections are made when installing.
5. Attach both the décor receptacle and IEC power inlet to the 2-gang Pocket Plates with mounting
screws, as shown in Fig 2. on reverse side.
6. Connect the 5’ Jumper to the décor receptacle and complete the interconnect by applying the metal strain
relief bracket and securing it with two mounting screws. SEE ‘Interconnect Assembly’ on reverse side.
7. Feed the 5’ Jumper through hole (A) to hole (B).—TIP: When dealing with insulation and other
obstructions in the stud cavity, there are many different fishing tools to aid in this process.
8. Connect the other end of the 5’ Jumper to the IEC Power Inlet and complete the interconnect.
9. Feed the remaining low voltage cables through hole (A) to hole (B) and push the ends through the
décor brush plates.
10. Once all the cables are fed through the wall, press both 2-gang Pocket Plates into the wall and secure
by tightening the two screws located on each box.
11. Reconnect your display to its wall mount if you disconnected it, and connect all remaining cables.
12. Connect the supplied power cord to the IEC Power Inlet and then connect to a nearby live wall outlet,
or surge protector.
Your Power Jumper IC™ is now ready for use.
Tools Needed:
1. Drywall Saw
2. Phillips Head Screwdriver
3. Level
4. Pencil
5. Measuring Tape
6. Stud Finder
Kit Includes:
(2) 2-Gang Pocket Plate with
pre-installed Décor Brush Plate
(1) Overmolded Décor Receptacle
(1) Overmolded IEC Power Inlet
(1) 5ft Interconnect Jumper
(1) 6ft Right Angle IEC Power Cord
(8) Receptacle Mounting Screw (#8 5/16)
(2) Interconnect Strain Relief Bracket
PN: M2PJCTVW5

IMPORTANT INSTRUCTIONS:
• Use the local electrical code approved installation when installing this product.
• The electrical parts in this kit are designed to complete the installation. Individual use of these devices may
be used in accordance to National Electric Code Requirements.
• This kit is not designed to be powered directly to the circuit panel.
• This installation is live (electrically energized) only when the supplied extension cord receptacle end is
plugged to the power inlet and the plug end is connected to a live wall outlet or surge suppressor that is
plugged into a live wall outlet.
• If you are not familiar with home wiring systems, please call a qualified electrician to install this product
• This Power Feed is not designed to be used as an extension cord outside the wall. Miss use of this power feed can
result in FIRE or DEATH by ELECTRICAL SHOCK. Please read these instructions carefully and follow ALL Directions.
Before USE:
• A Cord set Not Marked for Outdoor or outside the wall use is to be used behind a wall in an indoor wall only.
• Inspect thoroughly before installation. DO NOT USE IF DAMAGED.
• Look for number of watts on Appliance to be plugged into Power Extender.
• See the label on Power Extender for Specific Wattage.
• Insure the receptacle you intend to plug the Power Extender into is not more than 15 AMPS and connected to
the circuit panel with a 15 Amp Circuit Breaker.
• Do not plug more than the specified watts into this Power Extender.
• Make sure Appliance is off before connecting Cord to outlet.
• Fully plug into Outlet.
• Do not remove bend or modify any metal prongs or pins of Power Extender.
• Insure Mounting devices are securely fastened to the wall and Power Extender is securely fastened to the
Mounting device.
• Fully insert plug into Outlets on all connections
• Do not use excessive force to Make Connections.
• Do not connect a three prong plug into a 2 hole cord.
• THIS IS A POLARIZED POWER FEED.
• Insure Installation meets all NEC code requirements. If unsure consult a licensed electrician.
During Use:
• Keep away from water.
• Do not use when wet.
• Keep Children and pets away from Power Jumper and IEC Cord Set
• Do not plug multiple extension cords from either end. Plug only the cord set that comes with the Appliance
into the Duplex Receptacle of the “Power Extender” and an IEC to NEMA 5-13P cord Set into the IEC Power
Inlet of the “Power Extender” to a surge protector or a live 15 amp receptacle.
• Do not over bend or apply excessive tension on either cord set plugged into the Power Jumper ends.
Product Use and Intended Application: Product shall be used in dry indoor premise or commercial wiring in
behind and permanently affixed to the interior wall, and be installed or fished in air voids, and joints, and
masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or
dampness. The Power Extender enables the installer to feed power to a HDTV mounted to the wall via an
extension cord plugged into the IEC end and then plugged into a live receptacle from an electrical branch wired
to the circuit panel. The product comes prewired so there is no wiring required by the installer.
(A)
(B)
5’ max
2-Gang Pocket PlateIEC Power Inlet
1 pc.
1 pc.
Conforms to STD 514D and Certified CSA STD 22.2 No. 42.1-00
Electrical Rating: 125 VAC, 15 AMPS, 60 Hz
Minimum Conductor Size: 14 Gauge
Max Operating Temperature: 90° C
UL 2256 / UL 2459 / UL 94 V-0
Patented with multiple patents pending.
SPECIFICATIONS:
Model Similarities – Length and Color, Black and White, 7, 8, 9, 10, 13, 15 feet.; Power Extender Electrical Rating 15 Amp,
125 Vac, 60Hz, 14 AWG Conductor, NEMA 5-15R Receptacle connected to a IEC 60320 CY14 power inlet. Power Jumper
Assembly Insulated Cable meets UL 514D, CSA STD 22.2 42.1-00 Power Jumper Assembly meets NEC Code: 250.146(D),
Isolated Receptacles, Interconnect meets UL 2256 and UL 2459. Power Jumper Assembly Cable, Type NM-B
(Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC).
The Power Jumper is compatible to NEC Article 300.15 (E) Integral Enclosure and NEC 334.40 (B) Devices of Insulating
Material and other NEC code requirements suitable for it intended application. All connector material used in the
Power Jumper Cable assembly (Polycarbonate) are rated UL 94 V-0, for its intended application.
14-2 Premise Wire Type NM-B cable may be used for both exposed and concealed work in normally dry locations at
temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National
Electrical Code. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not subject to
excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts.
WARNING
MIDLITE® products shall be installed and used only as indicated in MIDLITE® product instruction sheets.
Instruction sheets are available online at www.midlite.com.
CAUTION
For shock protection, this device must be properly grounded. Use copper wire only with this device.
IMPORTANT INSTRUCTIONS
Read and understand all instructions. Follow all warnings and instructions marked on the product. Remember this
product is not part of your home’s electrical wiring system Do not install in areas near water such as swimming
pools, baths, sinks, showers, tubs and wet basements.
SAVE THESE INSTRUCTIONS.
2-Gang Pocket Plate
Décor Receptacle
5’ Jumper
Fig 1.
Fig 2.
PN: M2PJCTVW5
Male End
Completed
Interconnect
Female End
Interconnect
Assembly
Table of contents