mIoT Captis Pulse Lite User manual

mIoT Captis Installation Guide September 2020
1 Rev 5
Installation Guide
Captis Pulse Lite

mIoT Captis Installation Guide September 2020
2 Rev 5
Contents
Introduction.............................................................................................................................................. 3
Captis Technical Information................................................................................................................... 3
Captis Pulse Lite Dimensions ............................................................................................................. 3
Captis Pulse Lite ................................................................................................................................. 3
Installation ............................................................................................................................................... 4
Before You Begin ................................................................................................................................ 4
What is in the Captis Box? .................................................................................................................. 4
Installing the Captis................................................................................................................................. 5
Mounting the captis ................................................................................................................................. 5
Terminating the device............................................................................................................................ 6
Termination Precautions ..................................................................................................................... 7
Selecting an external antenna ............................................................................................................ 8
Installing the external antenna ............................................................................................................ 9
Checking Sensor & Cellular Connections ............................................................................................. 10
Troubleshooting .................................................................................................................................... 11
Maintenance & Safety ........................................................................................................................... 12
Maintenance...................................................................................................................................... 12
Electromagnetic Radiation – Human Exposure ................................................................................12
Battery handling & disposal............................................................................................................... 12

mIoT Captis Installation Guide September 2020
3 Rev 5
INTRODUCTION
The Captis cellular data logger has been developed to fill measurement requirements across a broad
range of applications and remote locations.
The Captis Pulse Lite has the following features:
•The device measures 90 x 75 x 50 mm and weighs less than 500g.
•Is designed to interface with existing mechanical water meter via a pulse pick up unit.
•It is battery operated and does not require an external power supply.
•It operates on LTE-M or NB-IoT cellular networks.
•The enclosure is IP68 rated.
CAPTIS TECHNICAL INFORMATION
CAPTIS PULSE LITE DIMENSIONS
CAPTIS PULSE LITE
1x Pulse Input Passive Suitable for Reed SW + Open Collector +
Dry Contact
Maximum Pulse Frequency 1000Hz
Sensor Minimum Open Resistance 1.25MΩ
Sensor Maximum Closed Resistance 60kΩ
Physical Size 90mm x 75mm x 50mm
Weight Less than 500g
IP Rating IP68
Figure 1 Captis dimensions front view
Figure 2 Captis dimensions side view

mIoT Captis Installation Guide September 2020
4 Rev 5
INSTALLATION
BEFORE YOU BEGIN
Before starting this installation, you will need the following items:
•The contents of the Captis box.
•The water meter that will be connected to the Captis
•A 3mm Allen key and small flat blade screwdriver
•An internet-connected device, such as a phone or tablet.
WHAT IS IN THE CAPTIS BOX?
In the Captis box you will find:
•Captis data logger
•Attachment Bracket
•Activation Magnet Tool
Used to wake up and reset the device.

mIoT Captis Installation Guide September 2020
5 Rev 5
INSTALLING THE CAPTIS
To successfully install the Captis you must perform the following steps. Each step is described in more detail
in the following sections.
1. Decide where to mount the Captis
2. Mount the Captis Pulse Lite to your selected location/ water meter
3. Test the wiring, sensor and cellular connection.
4. Complete the physical installation after testing.
MOUNTING THE CAPTIS
Consider the following points when deciding on the mounting location for the Captis:
•If the Captis device is installed underground or inside a metal cabinet, an external LTE antenna must
be used. Ensure that your Captis device supports external antenna connection. The antenna lead
must be routed to an open area where cell signal is less obstructed.
•Ensure there are no physical obstructions to the cell signal reaching the antenna. This applies to
both models of Captis devices with an internal antenna or an external antenna.
The Captis devices can be mounted in a range of positions and methods. Around the Captis enclosure there
are:
-2 Screw tabs for wall mounting.
-Vertical and Horizontal channels to accommodate a standard 15mm pipe clamp or cable ties.

mIoT Captis Installation Guide September 2020
6 Rev 5
TERMINATING THE DEVICE
The Captis Pulse Lite is provided with a four-pin plug that can be connected to one or two sensors and/or
measurement devices. Use the table below to determine how to wire the connections between the Captis
Pulse Lite and the sensor.
PIN
Description
1
Pulse –
2
Pulse +
3
Switch +
4
Switch –
Receptacle on Pulse Lite device

mIoT Captis Installation Guide September 2020
7 Rev 5
TERMINATION PRECAUTIONS
When connecting the Captis to a sensor:
•Ensure that the connection is sealed and insulated appropriately.
•Ensure that the connection is made electrically safe.
•Isolate any unused cables.
To ensure the efficacy of your Captis on-site installation and the on-going safety and sustainability of your
installation, mIoT recommends that you follow these best practice procedures for terminating and
waterproofing your sensor connection.
TERMINATION:
To ensure on-site sensor connections remain intact, the Captis can be configured with a loopback cable cut
detection. It is recommended that this loopback is performed as close to the sensor as possible, giving the
best possible tamper coverage of the sensor cable.
WATERPROOFING & PROTECTION OF TERMINATIONS:
mIoT recommends that standard electrical termination waterproofing
procedures are followed, including the use of suitably IP rated
junction boxes, scotch locks, solder terminations and other terminal
style connections.
These terminations are recommended to be water-proofed by means
of resin-filled heat shrink or self-amalgamating tape or other
standard, secure electrical waterproofing means.
WATERPROOFING & PROTECTION OF SMA CONNECTOR:
When the SMA connector is securely fastened (finger tight only) to the Captis’ SMA connector, the seal
which is enclosed within the connector (on the antenna side) creates a seal against the housing preventing
moisture intrusion.
Further protection can be added if required by the installer by using a small piece of resin filled heat shrink or
self-amalgamating tape to further protect the connector.
OTHER BEST PRACTICE CONSIDERATIONS:
Do not suspend the Captis by the cable.
Do not stress the exit port of the Captis unit.
Do not introduce any severe or unnecessary bends to the cable.

mIoT Captis Installation Guide September 2020
8 Rev 5
SELECTING AN EXTERNAL ANTENNA
mIoT recommended antennas include:
Taoglas Cyclops WM.90
698 – 960MHz/1719-2690MHz
Wide-Band High Efficiency
Flexible Inner Steel Core Whip, IP65
3M CFD-200 SMA(M)ST
RoHS & Reach Compliant
Taoglas Phoenix GSA.8827
698-960MHz/1575.42MHz/1710MHz-2700MHz
No Ground Plane Required
1M RG-174 SMA(M)
105mm x 30mm x 7.7mm
Taoglas T-Bar GSA.8822
4G/3G/2G LTE T-Bar Adhesive Antenna
GSM/CDMA/PCS/DCS/UMTS/WCDMA/LTE
700/850/900/1800/1900/2100/2600MHz
3M RG-174 SMA(M)
106mm x 13mm x 6.7mm
Poynting OMNI-510-01
690MHz – 2700MHz Max
Omni-Directional
IP68/UL 94-HB/IK10
1M RTK-031, RA SMA(M)
138mm x 26mm x 10mm

mIoT Captis Installation Guide September 2020
9 Rev 5
INSTALLING THE EXTERNAL ANTENNA
Note: This step is only applicable if your device supports an external antenna.
Connect an LTE antenna to the device’s external SMA connector. Make sure not to over tension the antenna
screw. No tools are required for this task.
Figure 3 External antenna connection
The external antenna must be installed in a location with the following characteristics:
•No physical obstruction to the signal reaching the antenna.
•Limited proximity to metal bodies.
If the Captis is installed in an enclosed area, an external antenna must be used. The end of the antenna
must be outside the enclosed area.
If there are no suitable surfaces on which to mount the external antenna, it can be attached to one of the flat
surfaces of the Captis enclosure.

mIoT Captis Installation Guide September 2020
10 Rev 5
CHECKING SENSOR & CELLULAR CONNECTIONS
Before leaving the installation site, you must check that the connection between the device and the sensor is
functional and that there is adequate cellular signal for the Captis to work as required.
1. Activate your sensor to create some measurements. How you do this will depend on the sensor.
2. Wake up the Captis using the magnet. If the device has been installed correctly and is able to
connect to a cellular signal, then it will then transmit the recorded data to the cloud platform.
3. Check that the data has successfully transmitted to the cloud platform in the correct format, and that
no alarms have been recorded.
If the data has been submitted correctly, the registration and installation are a success. If the data does not
appear, see Next Step: ‘Troubleshooting’.
CHECKING THE CELLULAR CONNECTION OF AN ENCLOSED DEVICE
If you are installing your Captis device in an enclosed space (i.e. a pit or cabinet) then you must check the
connectivity of the device in the environment in which it will ordinarily operation.
For example, if you are installing a Captis device inside a metal cabinet, then you must test that the device is
able to connect to the cellular network when the cabinet is closed.
Note: It is insufficient to test connectivity with the cabinet open.
Follow the below steps to check that the Captis device can connect to the cellular network in its final,
enclosed installation location.
1. Wake the Captis device and ensure that it is installed in its final, enclosed environment.
2. You will have 10 seconds to encase the device before it attempts to connect to the network.
3. Wait 5 minutes and then check that the device has connected to the cloud platform.
4. If the device appears in the platform, then the device can achieve enough connectivity and has
successfully connected in its final installation location.

mIoT Captis Installation Guide September 2020
11 Rev 5
TROUBLESHOOTING
Symptom Meaning What to do
Status LED flashing 20 times Device is on/ awake Device is working as it should, leave
device to collect data
Cellular LED solid Device connected to
LTE network
Device is working as it should, leave
device to collect data
Status LED won’t turn on after
using the magnet
The device battery may be
depleted, or a device fault may
have occurred
Use a different device and contact
the supplier
Status LED flashing in
sequence: 2 long 1 short
No cellular registration
(connection to the network) is
being achieved.
Check with the Telstra coverage map
to ensure the site is covered by the
LTE-M or NBIoT cellular network.
If the area is covered, and the device
cannot connect, contact the supplier.
Status LED flashing in
sequence: 2 long 8 short
Captis device cellular module
failed to boot
Return the device to the supplier if
the issue persists.
Sensor connection not working
(not flashing the LED after LED
flash turned on in Captis
Configuration Toolset)
Connection wired incorrectly
Confirm that the sensor is properly
attached.
Contact support if issue persists
Sensor readings not
uploading to/appearing in
the cloud platform
Sensor not triggering
Ensure the sensor can be triggered
by checking that the sensor is
securely installed.
Contact support if issue persists
No cellular signal
Check Status and Cellular LED.
If flashing, complete troubleshooting
for a flashing Cellular LED.
Contact support if issue persists

mIoT Captis Installation Guide September 2020
12 Rev 5
MAINTENANCE & SAFETY
MAINTENANCE
The Captis device does not require any maintenance once installed. The Captis uses a non-
rechargeable Lithium ION battery, and there are no user serviceable parts inside the device.
If you encounter any issues with the device during its standard operation, contact your support team.
ELECTROMAGNETIC RADIATION – HUMAN EXPOSURE
Warning: This device has a Maximum Permissible Exposure (MPE)
radius of 20cm.
It is the installer’s and end customer’s responsibility to ensure that no person has any body parts
within 20cm of the device or antenna while device is transmitting. Device is transmitting when the
‘Cellular’ LED is lit.
BATTERY HANDLING & DISPOSAL
This Captis devices uses a Lithium ION Battery.
The Captis device should not be tampered with, drilled directly into for mounting purposes, otherwise
opened, or crushed. If necessary, the Captis device should only be disposed or destroyed of in a safe
and environmentally compliant manner.
Visit the Australian Battery Recycling Initiative (ABRI): https://batteryrecycling.org.au/recycle-
batteries/why/find-a-recycler/ for more information on lithium battery disposal in your state and across
Australia.
Note: There are no user serviceable parts inside the Captis device.
Opening the Captis device will void the device warranty, and could cause significant damage to the
device.
Other manuals for Captis Pulse Lite
3
Table of contents
Other mIoT Data Logger manuals
Popular Data Logger manuals by other brands

Huace Navigation Technology
Huace Navigation Technology LT500XYZ Operational description

Omega
Omega OM-EL-WiFi Series user guide

Blue Gizmo
Blue Gizmo BG 38TC instruction manual

inelo
inelo TachoReader Combo Plus Tutorial

Chauvin Arnoux
Chauvin Arnoux AEMC DL913 user manual

RAWLINK
RAWLINK 36685 instruction manual