Mitsubishi Electric PAC-KD02DM-FA User manual

1
PRECAUTIONS BEFORE TEST RUN
PRECAUTIONS BEFORE REMOVE AND ELECTRIC WORK
WARNING
Always have the unit installed by Authorized Mitsubishi
Representative or similar professional.
Improper installation by the user could result in problems such as
water leakage, electric shock or fire.
Install the unit according to this Installation Manual.
If the unit is installed improperly, water leakage, electric shock or fire
may result.
Always use the designated cables and connect them properly.
When connecting the terminals, make sure that external forces
from the cable is not being conveyed to the terminal and then
tighten it securely.
Improper or loose connections could cause excessive heat or fire.
Only use Mitsubishi-approved accessories, such as an air clean-
er, humidifier or electric heater.
Always have such accessories installed by an Authorized Mitsubishi
Representative or similar professional. Improper installation by the
user may result in water leakage, electric shock or fire.
Have all electric work performed by a properly licensed electri-
cian. Electric work should be performed in strict adherence to
procedures to this Installation Manual. Always provide a dedicat-
ed power supply.
If the capacity of the power supply is inadequate, it could result in prob-
lems such electric shock or fire.
Never modify the unit and always have repairs performed by an
Authorized Mitsubishi Representative.
Improper repair could result in problems such water leakage, electric
shock or fire.
This installation manual contains only the description of how to install the Drain water Lift-Up Kit PAC-KD02DM-FA. For information about how to
wire and how to install air conditioning units, see the installation manual for them.
For your safety, first be sure to read “ 1 Safety Precautions “ described below thoroughly and then install the Drain water Lift-Up Kit PAC-
KD02DM-FA correctly.
This symbol denotes what could lead to serious injury or death if your misuse the PAC-KD02DM-FA.
This symbol denotes what could lead to a personal injury or damage to your property if you misuse the PAC-KD02DM-FA.
●The following two symbols are used to denote dangers that may be caused by incorrect use and their degree:
●After reading this installation manual, keep it in a place where the final user can see it anytime he or she wants to it.
When someone moves, repairs or uses the PAC-KD02DM-FA, make sure that this manual is forwarded to the final user.
.WARNING
.CAUTION
Never use for special applications such as storing food, plants,
precision equipment or art.
The quality of these items may deteriorate.
Always provide adequate signal noise protection when installing
in facilities such as hospitals and communication stations.
Equipment at these facilities, such as inverters, in-house generators,
high-frequency medical equipment, two-way communication equip-
ment, may cause the air conditioner to operate improperly. Conversely,
the signal noise from the air conditioner may affect the operation of
medical equipment and two-way communication equipment and this
could interfere with the medical treatment being given a patient or
cause disturbances or interference in video broadcasting equipment.
Never operate the air conditioner with the air filter removed.
Particles will enter into the air conditioner and cause damage.
Route wiring so that there is no tension.
Tension could cause the wire to break and this could result in exces-
sive heat or fire.
Dispose of packing materials properly.
Never use the unit in special environments.
Special environments with high concentrations of oil, steam or sulfuric
gases will reduce the performance of the air condition and cause its
parts to deteriorate.
Never turn off the power supply immediately after stopping the
unit.
Wait five minutes or more before turning off the power supply. Turning
off the power supply before that time could result in water leakage or
damage.
Never install the unit where run-off could result in damage.
If the humidity in the room exceeds 80% or if the drain becomes
clogged, water may drain off of the indoor unit. When the unit is used
for heating, there may be drainage from the outdoor unit. If required,
provide collector drain for the outdoor unit.
Use care when transporting the unit.
•Always use two or more people for lifting a product weight 20 kg. or
more.
•Some products are packaged with plastic wrapping bands. Never use
these for lifting or transporting the product.
•Never touch the fins on the heat exchanger. They are sharp and
could cause cuts.
•Never allow children to play with the plastic bags used for packaging.
Always tear them up when disposing. Achild could suffocate in these
bags.
Never touch the switch with wet hands.
Electric shock could occur.
Never operate the air conditioner with the panel or guard removed.
The hand could come in contact with rotating, hot or high-pressure
components. They could cause electrical shock or entanglement.
MITSUBISHI ELECTRIC
Air Conditioning For Building Application
Drain Water Lift-Up Kit PAC-KD02DM-FA
Installation Manual
WT04433X02
1 Safety Precautions
CAUTION
PRECAUTIONS BEFORE INSTALLATION

2
2 Confirming the Supplied Parts
1. Model names and applicable models
PAC-KD02DM-FA
PDFY-P20VM-A,PDFY-P25VM-A,PDFY-P32VM-A,PDFY-P40VM-A,PDFY-P50VM-A,
PDFY-P63VM-A,PDFY-P71VM-A,PDFY-P80VM-A,PDFY-P100VM-A,PDFY-P125VM-A,
Model name Applicable types
PDFY-P20VM-E,PDFY-P25VM-E,PDFY-P32VM-E,PDFY-P40VM-E,PDFY-P50VM-E,
PDFY-P63VM-E,PDFY-P71VM-E,PDFY-P80VM-E,PDFY-P100VM-E,PDFY-P125VM-E,
PDFY-10NMU-A,PDFY-16NMU-A,PDFY-24NMU-A,
PDFY-32NMU-A,PDFY-40NMU-A,PDFY-48NMU-A
PDFY-P06NMU-E,PDFY-P08NMU-E,PDFY-P12NMU-E,PDFY-P15NMU-E,PDFY-P18NMU-E,
PDFY-P24NMU-E,PDFY-P27NMU-E,PDFY-P30NMU-E,PDFY-P36NMU-E,PDFY-P48NMU-E
2. Provided parts
Check that the packet includes the following parts in addition to this installation manual.
1DRAIN PUMP ASSY. 2PUMP COVER ASSY. 3RUBBER PLUG 4BAND
1111
SHAPE
Q'TY
PARTS
5PTT SCREW 4X10 6SCREW 4X10 7CONNECTOR
SHAPE
Q'TY
PARTS
✻8WIRING ASSY. A1
✻8-C; Use for PDFY-10, 16, 24, 32, 40, 48NMU-A
✻9WIRING ASSY. A2 ✻0WIRING ASSY. B
111
221
SHAPE
Q'TY
PARTS
✻AFUSE HOLDER ✻BFUSE ✻CPTT SCREW 3.5X10
111
SHAPE
Q'TY
PARTS
PDFY-P08,P15,P24,P30,P36,P48NMU-E type only.
(Light brown)
250V 5A
PDFY-10,16,24,32NMU-A
Yellow
Green Red
PDFY-40,48NMU-A
PDFY-P08,P15,P24,P30NMU-E PDFY-P36,P48NMU-E
To “L1”To
Red
To “L1”
Red Blue
White

3
3 Attach the Drain Pump
1.Cover removal
(1) Remove the two screws used to attach the cover.
(2) Remove the cover.
Cover
2. Attach the drain pump
Cover
(A)
Make a hole
White
connector
(Large)
White
connector
(small)
PTT screw➄
Band➃
Drain pump assy➀
Pump cover➁
(1) Make a hole in cover by removing cutout (A).
(2) Attach the drain pump assembly➀to the pump cover
using the two PTT screws➄.
(3) Pull the lead with the white connector through the
opening in the side of the pump cover➁, pull the lead
with the white connector over the top of the pump
cover➁, and then bind the two leads with a band➃.
(4) Temporarily turn in the light brown screws➅in the
socket section of the drain assembly, 3 to 5 times.
Screw➅
(Light brown) Screw➅
(Light brown)
(B)
Rubber plug➂
(C)
Drainage outlet
of the socket
(5) From the inside of the unit, insert the slightly tightened screws➅
through the screw holes shown by (B) , and then slowly lower the
assembly so that the screws slide into the notches.
(6) While being careful not to twist the drain pump assembly tube, re-install
the cover.
(7) Finish tightening the light brown screws➅.
(8) Pass the drainage outlet of the socket through hole (A) in the cover.
(9) Attach the cover using the two screws.
(10) Fully install the rubber plug➂onto the drainage outlet shown by (C).

4
4 Wiring
[ In the case of PDFY-P20~125VM-A and PDFY-P20~125VM-E ]
1. Pass the white connector (3P:small) of the drain pump
assembly through rubber bushing (A) and the white
connector (3P:Large) through rubber bushing (B).
Cover
Cover securing screw
(2 places)
Circuit board
CN60
CN31CN29
<Side view><Front view>
Circuit board
White connector
(3P:small)
Short-circuit
connector
Exchange
Black connector(4P)
White connector(3P)
Red connector(2P)
(For trial operation of the drain pump)
2. Remove the screws, and then remove the control box cover.
3. Remove the short-circuit connector at CN31 on the
circuit board and insert the white connector
(3P:small) of the drain pump assembly.
4. Insert the white connector(Large) on one of the
leads of the drain pump assembly into the white
relay connector at the side of the control box.
5. If there is slack in the leads, bind them with the clip
on the control box.
Rubber bushing
(B)
White Connector
(Large)
White Connector (small)
Rubber bushing
(A)

5
1. Pass the white connector (3P:small) of the drain pump
assembly through rubber bushing (A) and the white
connector (3P:Large) through rubber bushing (B).
Indoor
Control box cover
Screw
Screw
Drain pump
connector
Drain sensor
connector
2. Remove the screws, and then remove the control box cover.
3. Run the drain pump and drain sensor wires through the holes shown below.
Rubber bushing
(B)
White Connector
(Large)
White Connector (small)
Rubber bushing
(A)
[ In the case of PDFY-10, 16, 24, 32, 40, 48NMU-A and PDFY-P06, P08, P12, P15, P18, P24, P27, P30, P36, P48NMU-E ]

6
CN3T
CN90CND CNT CNP
CN2M
CN3A
CN20 CN31
CN60
CN3T
CND
CN2M
CN53
FAN1 CNT
FAN2
CN31CN20
CNP
CN42CN81
CN3ACNV
W893038H01 Transmission.
M-NET Remo.Con.
TB5
TB15
MA Remo.Con.
12
M1 M2 S
CAUTION
Never connect
Power source
W893038H01 Transmission.
M-NET Remo.Con.
TB5
TB15
MA Remo.Con.
12
M1 M2 S
CAUTION
Never connect
Power source
G
W896247H01
L1 L2
Power source
G
W896247H01
L1 L2
Power source
Blue
White
Drain pump
connector
DSA board
Connect to
CN31
9WIRING
ASSY. A2
@WIRING ASSY. B
Connector for
DSA board
Yellow
Remove
Short-circuit
connector
v
@WIRING ASSY. B
v
vi
Drain pump
connector
vi
iv
8WIRING
ASSY. A1
iv
i
ii
Connect to
CN31
Remove
Short-circuit
connector
Remove
i
ii
From
drain sensor AFUSE
HOLDER
BFUSE
CPTT SCREW
3.5X10
iii
From
drain sensor
Procedures
Warning: Perform the following procedures with the power being turned off.
iii. Fix the fuse holder (item A) with the PTT screw (item C) to the control box, and attach the fuse (item B).
iv. Connect wire assembly (items 8or 9).
Note.Item 9(wire) is intended for PDFY-40, 48 NMU-A and PDFY-P36, P48NMU-E. Do not use it for other types.
i. Remove the short-circuit connector on CN31.
* In the case of PDFY-10,16, 24, 32 NMU-A and PDFY-P06, P08, P12, P15, P18, P24, P27,P30NMU-E also
remove the yellow connector on the DSA board.
ii. Connect the drain sensor wire to CN31.
v. Connect wire assembly (item @) to CNP12.
vi. Connect the drain pump connector to wire assembly (item @).
AFUSE
HOLDER
BFUSE
CPTT SCREW
3.5X10
iii
Blue
4. Connect the wires as shown in the figures below.
5. If there is slack in the leads, bind them with the clip on the control box.
PDFY-10, 16, 24, 32NMU-A
PDFY-P06, P08, P12, P15, P18, P24, P27, P30NMU-E
PDFY-40, 48NMU-A
PDFY-P36, P48NMU-E

7
5 Drain piping work
1. Ensure that the drain piping is downward (pitch of more than
1/100) to the outdoor (discharge) side. Do not provide any trap
or irregularity on the way. (Fig. 5-1)
2. Ensure that any cross-wise drain piping is less than 20 m
(excluding the difference of elevation). If the drain piping is long,
provide metal braces to prevent it from waving. Never provide
any air vent pipe. Otherwise drain may be ejected.
3. Use a hard vinyl chloride pipe VP-25 (with an external diameter
of 32 mm) for drain piping.
4. Ensure that collected pipes are 10 cm lower than the unit
body’s drain port.(Fig. 5-2)
5. Do not provide any odor trap at the drain discharge port.
6. Put the end of the drain piping in a position where no odor is
generated.
7. Do not put the end of the drain piping in any drain where ionic
gases are generated.
8. The intake of the drain piping can be made 41 cm higher than
the drain discharge port. If there are some obstacles under the
ceiling, use elbows to make it at least height according to the
site. (Fig. 5-3)
Downward pitch of
more than 1/100
Metal brace
Insulating material
25 cm
1.5 – 2 m
Fig. 5-1
Indoor unit Indoor unit Indoor unit
Collecvtive piping
Take as large as possible.
About 10 cm
Fig. 5-2
within 41cm
Less than 300 mm
Drain hose
(Accessory)
Tie band (small)
(Accessory)
Hard vinyl chloride 90˚
elbow (field supply)
Hard vinyl
chloride (VP-25)
(field supply)
Hard vinyl chloride 90˚
elbow (field supply)
Be sure to use the supplied drain hose (Accessory).
▲▲
Connect each connection with vinyl chloride adhesive. But never
use any adhesive over the indoor unit discharge port. Otherwise
the drain-up mechanism cannot be serviced later. Also, the end
connection may be eroded by resin and so cracked.
Fig. 5-3
Note:
If the rise portion is long, there will be a lot of returned water
in an operation stop, generating slime or odor during off-sea-
son. Ensure that the rise portion is at a minimum.
Pipe the drain piping to ensure that it discharges drain, and
insulate it to prevent dew condensation. A failure to the pip-
ing work may cause water leakage and so wet your property.
6 Confirming drain discharge
1. Insert the enclosed connector➆into the red connector (2P) on the side of the
control box.
2. Remove the polyethylene plugBon the same side as the indoor unit piping.
3. Fill water into the feed water pumpAusing a feed water tank. In filling, be
sure to put the end of the pump in drain pan. (If the insertion is incomplete,
water may flow over the machine.)
4. Turn on the main power. The drain pump is forced to operate without any
remote controller operation. Make sure using a transparent drain hose(acces-
sory) that drain is discharged.
5. After confirmation, turn off the main power, remove the connector, and insert
the polyethylene plug into its original position, insulate drain hose.
AInsert the pump’s end 2 to 4 cm.
BRemove the polyethylene plug.
CAbout 1000 ml
DWater
EFilling port
Caution:
Make sure that the drain-up mechanism operates normally for discharge
and that there is no water leakage from the connections.
•Be sure to confirm the above in a period of heating operation.
•Be sure to confirm the above before ceiling work is done in the case of a new
construction.
▲

Table of contents
Other Mitsubishi Electric Water Pump manuals
Popular Water Pump manuals by other brands

airbox
airbox Variflow 8 user manual

Grundfos
Grundfos JP Series Installation and operating instructions

ITT
ITT Goulds Pumps HSUL Installation, operation and maintenance manual

Espa
Espa DRAIN instruction manual

Xylem
Xylem LOWARA Micro 10 Installation and Maintenance

RIDGID
RIDGID RSM3300 Operating instructions and parts manual

Balboa Water Group
Balboa Water Group SUPER WOW SPA PUMP Owner's and operator's manual

Graco
Graco 24B322 Repair manual

Rompa
Rompa 18682 quick start guide

SFA
SFA Sanicubic 1 GR HP 2.0 S Operating & installation manual

Dover
Dover Almatec Quattroflow-20k Series user manual

Neptune
Neptune MP7100 Installation operation & maintenance