MK K5440R Manual

®
K5440R
2 LEVEL REPEATER
Installation & Operating Instructions
This repeater is used to increase the range between Echo transmitters
and receivers. In 1-level operation, a radio signal received from a
transmitter will be passed on to the respective receiver. In 2-level
operation a radio signal can be passed over a maximum of two
repeaters to a receiver! The repeater is factory preset for 1-level
operation when delivered.
SAFETY:
CAUTION! 230V, Danger of electrical shock! Always
disconnect the electricity supply before commencing work on
the installation.
The device should be installed by a competent person or a qualified
electrician in accordance with the device’s installation instructions and
the appropriate current national wiring regulations.
It is essential that all connections are made as instructed, that cables are
not stressed and that terminals are fully tightened.
Screwless terminals must not have more than one cable inserted into
each terminal.
The mains supply to this product must be protected by an appropriate
fuse or MCB.
SPECIFICATION:
General Data
Transmit frequency 868.3MHz
Power supply 230V~ / 50Hz
Power line protection Circuit breaker rated for 10A max
Ambient temperature -20 to +40°C
Test specifications EN 60669-2-1
Protection type IP20
RF RANGE:
The strength of the radio signal between the transmitter and switching
receiver weakens as distance increases. The range can be further
reduced by different materials or interference sources in the propagation
direction of the radio waves. The range can be increased by the use of
Echo Repeaters (radio amplifiers).
Material Reduction
Wood, plaster, non-coated glass 0 - 10%
Masonry, wood/plaster walls 5 - 35%
Reinforced concrete 10 - 90%
Range Conditions
> 30 m Under good conditions (large, clear space without
obstructions).
> 20 m
Through up to 5 plaster/drywall board walls or 2
brick/porous concrete walls (furniture and persons in
the room):
For transmitter and receiver with good aerial
positioning/layout.
> 10 m
Through up to 5 plaster/drywall board walls or 2
brick/porous concrete walls (furniture and persons in
the room):
For receivers installed in walls or corners of rooms,
receivers with internal aerial or narrow corridors.
Through 1-2
ceilings / walls
Depending on ceiling/wall armouring and type of
aerial in the receiver.
INSTALLATION:
Important: This device should be installed into a flush mounted
installation box.
It should be installed in an area between the Echo sender and receiver.
Radio signals received from the sender can then be optimally passed on
to the receiver.
• Install flush-mounted installation box in a suitable position.
• Protect power supply cable with a circuit breaker or fuse (max. 10A)
• Install the connecting wires.
• Insert the device into the flush-mount installation box and screw-
fasten it securely in place.
• Affix the blind cover (Art. no.: xx.477.xx) to the device.
Note: NEVER install the repeater in a metal housing or in the immediate
vicinity of large metal objects. Installation close to floor level or on the
floor is not recommended.
Commissioning
• Switch on electric power after installation.
• The repeater is factory preset for 1-level operation when delivered.
Change the repeater to 2-level operation if this is desired.
OPERATION AND FUNCTIONS:
Manual operation of this device is not possible. The receiving and
sending of Echo radio signals is done automatically.
1 Level Operation
In 1-level operation, a radio signal received from a transmitter (LED
1blinks red) will be passed on to the respective receiver.
Transmitter 1-level operation Receiver
In 1-level operation, a radio signal received from a transmitter (LED 1
blinks red) will be passed on to the respective receiver.
2 Level Operation
In 2-level operation (LED 2 blinks red) a sender’s radio signal will be received and
passed on over a maximum of two repeaters to the respective receiver.
Transmitter 1-level operation 2-level operation Receiver
Activating 2-level operation:
Press button 2 LEV
longer than 2s LED 2 lights up for about 3s
(2-level operation is active)

TROUBLESHOOTING:
New system or existing system
• Check circuit breaker and power supply (electrician only).
• Check connection cables (electrician only).
• Check the system’s surroundings for changes that could cause interference (e.g.
metal cabinets, furniture or walls which have been moved).
• Use the repeater at a better location.
Radio signal range limitations
• Use of the receiver in the vicinity of metal objects or materials with metal
components. Maintain a distance of at least 10cm
• Moist materials.
• Devices which emit high-frequency signals (e.g. audio and video systems,
computers, electronic ballasts in light fixtures). Maintain a distance of at least
0.5m
OTHER INFORMATION:
Disposal:
At the end of their useful life the packaging and product should
be disposed of via a suitable recycling centre. Do not dispose
of with your normal household waste. Do not burn.
EU R&TTE Declaration:
Novar ED&S Ltd hereby declares that the K5440 Repeater is in
compliance with the essential requirements and other relevant
provisions of the European Radio and Telecommunications
Terminal Equipment (R&TTE) directive, 1999/5/EC.
A copy of the Declaration of Conformity for this product may be found at:
www.electrical.honeywell.com
Guarantee:
MK Electric undertakes to replace or repair at its discretion goods should
they become defective within 10 years solely as a result of faulty
materials and workmanship. Understandably if the product has not been
installed, operated or maintained in accordance with the instructions,
has not been used appropriately or if any attempt has been made to
rectify, dismantle or alter the product in any way the guarantee will be
invalidated.
The guarantee states MK Electric’s entire liability. It does not extend to
cover consequential loss or damage or installation costs arising from the
defective product. This guarantee does not restrict, infringe or in any
way affect the normal statutory or other rights of the consumer.
For help and advice please contact the technical service helpline: 01268 563720
MK Electric Telephone: +44 (0)1268 563000
The Arnold Centre, Paycocke Rd, , Fax: +44 (0)1268 563404
MK Electric (Middle East) Telephone: (+971) 4 807 3200
Honeywell ME, FZE, P.O. Box 18530, Fax: (+971) 4 881 5733
Jebel All, Dubai U.A.E.
www.electrical.honeywell.com
Novar ED&S Ltd, (A Honeywell Company)
Arlington Business Park, Bracknell,
Berkshire, RG12 1EB, UK
Copyright Novar ED&S Ltd 2011. All rights reserved.
50064836-001_A