Mobotix MxSwitch Instructions for use

MX-SWITCH
32.797-001_EN_12/2016
Quick Install
MxSwitch
Standard Delivery
MxSwitch
MxSwitch
5-port network switch for top-hat rail installation, for com-
bined network connectivity and PoE+ power supply of up to
four MOBOTIX door stations, cameras or other PoE+ devices
More information:
www.mobotix.com > Products > Home Automation > MxSwitch
• MxSwitch top-hat rail module with ip-top lid
Connectors – Overview
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
4 PoE+ ports (@ max. 25.5 W,
total load max. 75 W)
Push-button switch
and terminals for
the protection
Network port
(e.g., router, computer)
Terminals
Power supply
(ext. power supply 48 V DC, min. 2 A)
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20Terminal #
Reserved for future extensions
(“Backbone”) Door opener
(max. 1 A)
Spare wire pairs
(Port A) Spare wire pairs
(Port D)
Safety Warnings
•
The MOBOTIX MxSwitch is only to be used in switch boxes and must
be installed on top-hat rails (also “cap rail” or “DIN rail”).
• This product must not be used in locations exposed to the dangers
of explosion.
• Only use an external power supply with 48 V DC and min. 2 A.
•
Make sure to respect the operating temperature range of 0 to +40 °C
for the MxSwitch.
•
Electrical installation: Electrical systems and equipment may only
be installed, modied and maintained by a qualied electrician or
under the direction and supervision of a qualied electrician in
accordance with the applicable guidelines. Make sure to properly
set up all electrical connections.
•
Network security: MOBOTIX products include all of the necessary
conguration options for operation in Ethernet networks in compli-
ance with data protection laws. The operator is responsible for the
data protection concept across the entire system. The basic settings
required to prevent misuse can be congured in the soware and
are password-protected. This prevents unauthorized parties from
accessing these settings.
Special Product Features
• Simple installation – just click onto top-hat rail.
• 4 PoE+-powered network ports (max. 25.5 W per port, max. 75 W
total load on all PoE+ ports combined)
• 1 network port for connecting LAN or computer (“Uplink”).
• Integrated power supply for door opener with 12 V DC, 1 A (e.g.,
switched by BellRFID or KeypadRFID).
• Unused wire pairs 4/5 and 7/8 of network installation cables for
PoE ports A and D passed through to terminals.
• Push-button switch activates 12 V DC for 90 sec. on terminals
17/18 (to temporarily disable the protection of the frames of
door stations and MxDisplay units).
•
Integrated extensibility for additional top-hat rail modules (“Back-
bone”).
Installing and Removing the MxSwitch
Caution – Danger of Life! Switch o all power to the switch box before working on the switch box and make sure that the
power lines do not carry any current!
1. Installing the Module
Place the module onto the top-hat rail at the desired location, then
gently press the module onto the rail at the indicated locations until
it clicks into place.
Aer the clips have clicked into place, you can easily slide the module
on the rail until you have positioned it properly.
2. Removing the Module
Remove the network cable and any other cables or wires; isolate blank
wire ends, if required.
Push a suitable screwdriver into the red clip on one side of the module
(top or bottom), then gently pull the clip from the housing until it clicks
into the open locked position. Repeat the procedure on the clip on the
other side and remove the module.
Aer removing the module, lightly press on the clips; they will jump
back into their original position.
Connecting the MxSwitch and the Powered Devices
1. Notes on Connecting
Terminals
2 4 6 8 10 12 14 16 18 20
1 3 5 7 9 11 13 15 17 19
• Terminals 1 to 4: Spare wire pairs 4/5 and 7/8 on network port A.
• Terminals 5 to 12: Reserved for future extensions (“Backbone”).
•
Terminals 13 to 16: Spare wire pairs 7/8 and 4/5 on network port D.
• Terminals 17/18: Power supply for disabling the the protection
(see
«Deactivating the The Protection»
).
• Terminals 19/20: Power supply for door opener (e.g., switched
by BellRFID or KeypadRFID).
2. Using the Spare Wire Pairs (Ports A and D)
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
Forthesetwoports,the wirepairs4/5 and7/8 have been looped through
to the terminals so they can be used for other purposes (see also sec-
tion
«Example Scenarios»
and the connection examples on page 2).
Make sure to use a standard network installation cable since you need
to apply crimping plugs inside the switch box or use a patch eld to
connect the cable to the MxSwitch.
3. Using the Uplink Port
This port can be used to connect to another switch (and thus to the
network) or to a router. If this port is not used, you can connect a
computer to congure the network devices powered by the MxSwitch.
Notes on Using the MxSwitch
1. LED Signals
LEDs for net-
work ports
LED for the
protection
The MxSwitch has the following LEDs:
• 4 LEDs to indicate activity on the network port above each LED.
• 1 LED lights up aer pressing the push-button switch. The LED
stays on as long as the wires for deactivating the the protec-
tion is powered (see the following
Section «Deactivating the The
Protection»
).
2. Deactivating the The Protection
If the wires for deactivating the the protection of a MOBOTIX frame
for a door station or an MxDisplay have been connected to the termi-
nals 17/18, you can press the push-button switch inside the module to
deactivate the the protection of the attached frames for at least 90 sec.
Duringthis time, you can use the supplied keyorrulertoopen the frames
and remove the door station modules or the MxDisplay, respectively.
Caution:
Aer connecting these wires,
always run a functional test
without modules in the frame
to make sure that disabling the the
protection actually works (please see the pertinent product documen-
tation).

MOBOTIX AG
Kaiserstrasse
D-67722 Langmeil
Phone: +49 6302 9816-103
Fax: +49 6302 9816-190
www.mobotix.com
Declaration of Conformity: www.mobotix.com > Support > MxMedia Library > Certicates
MOBOTIX, the MX logo, MxControlCenter, MxEasy, MxPEG and MxActivitySensor are trademarks of MOBOTIX AG
registered in the European Union, the U.S.A., and other countries • Information subject to change without notice
• MOBOTIX does not assume any liability for technical or editorial errors or omissions contained herein • All rights
reserved • © MOBOTIX AG 2016
Technical Specications
MxSwitch
Controls Push-button switch inside puts 12 V DC
for 90 sec. on terminals 17/18
Power Supply Ext. power supply 48 V DC, min. 2 A
Operating Conditions Indoor, operating temperature
0 to +40°C
Dimensions
108 x 61 x 90 mm/
4.25 x 2.40 x 3.54 in (W x H x D)
W
D
H
MxSwitch
Cross-sectional area
of wires at the termi-
nals
0.2 to 2.5 mm²/24 to 14 AWG
Connections
• 2 terminals for ext. power supply
48 V DC
• 5 Ethernet connectors, 4 PoE+ (max.
combined total load 75 W), 1 uplink
(without PoE)
• Terminals 1 to 4 (Port A) and 13 to 16
(Port D) loop through wire pairs 4/5
and 7/8 of network cables
• 8 terminals for backbone pins (exten-
sion connector, reverse)
• 2 terminals for power supply 12 V DC,
1 A
• 2 terminals with 12 V DC, controlled by
push-button switch (see
«Controls»
)
Example Scenarios
1. Two Door Stations, One M15, One MxDisplay
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
=
Bridge #1 Bridge #2
• PoE power supply of all devices on ports A to D.
• Door stations attached to ports A and D.
• M15 and MxDisplay attached to ports B and C (PoE only).
• Bridge #1 at MxSwitch connects push-button key for the pro-
tection to wire pair 7/8 of the ports A and D.
• Bridge #2 at MxSwitch connects 12 V DC to wire pair 4/5 of the
ports A and D.
• Connect wire pair 7/8 of the network installation cable to the
protection of door station frames.
• Connect wire pair 4/5 of the network installation cable to signal
output of the BellRFID or KeypadRFID, respectively.
• Connect the signal outputs at the BellRFID and the KeypadRFID
to the door opener of the corresponding door.
2.
TwoDoorStations,One M15, One MxDisplay, TwoMX-DoorMaster
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
=
Bridge #1
Dierences to Scenario
1
:
• Bridge #2 (see above) at the switch is omitted.
• Connect each wire pair 4/5 of the network installation cable to
the MxBus connector of the corresponding door station.
• Connect each wire pair 4/5 of the ports A and D at the MxSwitch
with the corresponding MX-DoorMaster.
• Connect the door openers of the respective doors to the corre-
sponding MX-DoorMaster.
3. Four Cameras
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
Output
=
Input
GPS
Patch cable
Network instal-
lation cable
MxBus wires
• PoE power supply of all devices on ports A to D.
• Connect wire pair 4/5 of the network installation cable to the
MxBus connector of the camera at port A.
•
Connect wire pair 4/5 of port A at the MxSwitch to an MxBus mod-
ule to which additional MxBus modules can be connected (such
as the MX-Output-Box and the MX-GPS-Box to the MX-Input-Box
in the example).
4. Three Cameras, One IR LED Light
Patch cable
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
=
Dierences to Scenario
3
:
• The spare wire pairs of ports A and D are not used.
• Instead of a camera, the module supplies an IR LED light (25 W,
with photoelectric switch) with PoE power.
Connection Example in SmartAccessSet With MX-DoorMaster
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
=
12 V DC 1 A
Door contact
MxBus
Door lock contact
Door opener
Front Door
MxSwitch
The Protection
(in frame)
T25 Smart Access Set
T25-CamCore
(back)
MX-OPT-IO2
(mounted in housing)
BellRFID connections (back)
MxDisplay+
T25BellRFID
Switch Box
Dr. Jones, MD
48 V DC 2 A
Power Supply
MX-DoorMaster
Network + PoE
Network + PoE
• Wire pair 4/5 connected to MxBus plug of the T25.
• Wire pair 7/8 connected to the protection.
Connection Example in SmartAccessSet Without MX-DoorMaster
Uplink A B C D
48 V DC IN
12 V DC90s4 57 87 84 5
MxSwitch
=
12 V DC 1 A
Door contact
MxBus
Door lock contact
Door opener
Front Door
MxSwitch
48 V DC 2 A
Power Supply
The Protection
(in frame)
T25 Smart Access Set
MX-OPT-IO2
(mounted in housing)
BellRFID connections (back)
MxDisplay+
T25BellRFID
Switch Box
Network + PoE+
Network + PoE+
Dr. Jones, MD
T25-CamCore
(back)
• Wire pair 4/5 connected to BellRFID signal output.
• Wire pair 7/8 connected to the protection.
Table of contents
Popular Switch manuals by other brands

HP
HP ProCurve 3500yl Series Specifications

Exsys
Exsys EX-3460 user manual

Cisco
Cisco 200E Series quick start guide

Guntermann & Drunck
Guntermann & Drunck DP-Vision-CAT-AR Installation and operation

Cisco
Cisco 4503 - Catalyst Switch datasheet

Weidmüller
Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Hardware installation guide