Modena UC 1230 DASS Owner's manual

User
Manual Book
Chiller & Freezer
Upright Chiller
Upright Freezer
UC 1230 DASS
UC 1460 DASS
UF 1230 DASS
UF 1460 DASS
Counter Chiller
Counter Freezer
CC 2121 DASS
CC 2151 DASS
CC 3181 DASS
CF 2151 DASS
CF 3181 DASS

TABLE OF CONTENT
Part 1: Safety Information 2
Environmental Notice 3
Part 2: Name of Parts 4
Part 3: Quick Start Guide 5
Control Panel 5
How To See & Change Set Temperature 6
How to Start Manual Defrost 6
How To Lock/Unlock the Control 7
Part 4: Maintenance 7
Cleaning and Maintenance 7
Part 5: Troubleshooting 8
Part 6: Specification 10
This guide book explains everything you need to know about your new
product. Please contact our Customer Care should you need further
assistance through www.modena.com.

2
Read the user manual book carefully
•Do not use mechanical devices or other means to accelerate the
defrosting process, other than those recommended by the
manufacturer.
•Do not use electrical appliances inside the food storage
compartments of the appliance, unless they are of the type
recommended by the manufacturer.
•Do not damage the refrigerant circuit.
•When positioning the appliance, ensure the supply cord is not
trapped or damaged.
•The refrigerant and insulation blowing agent inside the refrigerator
need special disposal procedure. Consult the disposal method with
related department
•Do not locate multiple portable socket-outlets or portable power
supplies at the rear of the appliance. Do not use plug adapter.
•To avoid hazard due to instability of the appliance, it must be fixed
in accordance with the instructions.
•Clean the surfaces that come in contact with food and accessible
drainage systems regularly
•If power outage occurs, unplug the power cord. Wait at least 10
minutes before starting the appliance to avoid damage to the
compressor.
•While carrying and positioning the appliance, do not damage the
cooler gas circuit.
•Do not store explosive substances such as aerosol cans with a
flammable propellant in this appliance.
•If the supply cord is damaged, it must be replaced by the
manufacturer, an authorized service agent or similar qualified
persons, in order to avoid a hazard.
PART 1: SAFETY INFORMATION

3
Environmental Notice
The packaging material used is recyclable. We recommend
that you separate plastic, paper and cardboard and give
them to recycling agents. To help preserve the environment,
the refrigerant used in this product is iso-butane (R600a) or
propane (R290), which does not affect the ozone layer and
has little impact on the greenhouse effect. According to
WEEE (Waste of Electrical and Electronic Equipment) guidelines, waste
from electrical and electronic devices should be collected separately. If
you need to remove of this appliance in the future, do not throw it away
with the rest of your domestic garbage. Instead, please take the
appliance to the nearest WEEE collecting agents, where available.

4
*Above picture is for reference only. Difference between the picture and actual
product may occur
**Feature and equipments differ by each product
PART 2: NAME OF PARTS
Control panel

5
Control Panel
Key Functions
To display target set point, in programming
mode it selects a parameter or confirm an
operation
To start a manual defrost
In programming mode it browses the parameter
codes or increases the displayed value
In programming mode it browses the parameter
codes or decreases the displayed value
To lock or unlock the keyboard
To enter in programming mode
To return to room temperature display
PART 3: QUICK START GUIDE

6
LED Light Meaning
LED
Mode
Description
ON
Compressor enabled
Flashing
Anti short circuit cycle delay enabled (AC parameter)
ON
Fans are enabled
Flashing
Fans delay after defrost
ON
Defrost in progress
Flashing
Dripping in progress
ON
Measurement unit
Flashing
Programming mode
ON
Measurement unit
Flashing
Programming mode
How To See & Change Set Temperature
1. To see the SET temperature, push the SET key, the set point will be
displayed.
2. To Change the SET temperature, push and hold the SET key for more
than 2 seconds. The value of the set point will be displayed and the
°C or °F LED starts blinking
3. Push the UP or DOWN arrow to select the desired temperature
4. Push the SET key again or wait 10s to finish the setting
How To Start Manual Defrost
Push the key for more than 2 seconds and manual defrost will start

7
How To Lock/Unlock the Control
1. Lock: Push the UP and DOWN arrow key together for more than 3
seconds until the “OF” message is displayed.
2. Unlock: Push the UP and DOWN arrow key together for more than 3
seconds until the “ON” message is displayed.
Cleaning and Maintenance
To make sure that the appliance is in optimum condition, the interior and
accessories must be cleaned regularly.
•Before performing cleaning activity, switch off the appliance and
unplug the power cord.
•Do not use abrasive cleaners.
•Clean the interior and accessories using cloth and lukewarm water.
After that, clean with clean water and dry completely.
•Dust can accumulate on the condenser and cause performance
drop. Clean the appliance condenser at least once a year using soft
brush or vacuum cleaner.
•After everything is dried completely, install the accessories and
appliance to the initial position.
•Clean the condenser & evaporator periodically from debris and dust
to ensure maximum performance
PART 4: MAINTENANCE
IMPORTANT!
Appliance must not be connected to the main electrical socket during
cleaning! Risk of electric shock!

8
Check the following before contacting our Service Center in the event
of malfunction
Problem
Possible Cause
Recommended Action
Appliance does
not work
•Power cord is unplugged
or loose
•Blown fuse or damaged
fuse
•Defective socket
•Insert power cord
correctly
•Check the fuse, replace if
needed
•Malfunction must be
repaired by qualified
electrician
Appliance is not
cold
•Thermostat not properly
adjusted
•Too much food
•Door is opened frequently
•Appliance is placed in hot
area
•Bad ventilation
•Frost accumulated inside
the appliance
•Adjust the thermostat until
it’s cold
•Rearrange or reduce the
food
•Do not open the door too
frequent
•Place appliance in a cool
and dry place
•Ensure adequate
ventilation
•Defrost and clean the
appliance
Appliance is too
cold
•Thermostat adjusted to
maximum position
•Adjust the thermostat with
lower setting
PART 5: TROUBLESHOOTING
WARNING!
Before troubleshooting, unplug the unit from power source. Only a
qualified technician is allowed to perform troubleshooting not stated
in this manual.
IMPORTANT!
There are some normal sounds during use (compressor sound,
circulating refrigerant sounds)

9
Problem
Possible Cause
Recommended Action
Dew outside of
appliance
•Ambient temperature and
humidity too high
•Place appliance in a cool
and dry place
Loud noise
•Appliance is touching the
wall or other object
•Appliance pipe is touching
other parts
•Reposition the appliance
and follow the minimum
distance
•If needed, bend the pipe
to avoid touching with
other objects

10
MODEL
UC 1230 DASS
UC 1460 DASS
Type
Upright Chiller
Upright Chiller
Color
Stainless
Stainless
No. of doors
2
4
No. of racks
3
6
Temperature range (°C)
-2 to +8
-2 to +8
Capacity (Liter)
420
910
Power Input (Watt)
360
490
Defrost Power Input (Watt)
360
570
Control panel
Digital
Digital
Refrigerant (Weight)
R290 (97g)
R290 (136g)
Rated Curent (A)
2.2
2.5
Rated Voltage (V)
220-240
220-240
Rated Frequency (Hz)
50
50
Product dimension
(WxDxH)(mm)
630×815×1950
1220×815×1950
Design and specification can change without prior notice to improve the quality of the
product. The illustration in this manual is schematic and can be different with your actual
product. The values on label or in other documents are according to laboratory test and
relevant standards. Values can vary depending on the actual operational and
environmental condition of the product.
PART 6: SPECIFICATION

11
MODEL
UF 1230 DASS
UF 1460 DASS
Type
Upright Freezer
Upright Freezer
Color
Stainless
Stainless
No. of doors
2
4
No. of racks
3
6
Temperature range (°C)
-22 to -18
-22 to -18
Capacity (Liter)
420
910
Power Input (Watt)
400
800
Defrost Power Input (Watt)
360
570
Control panel
Digital
Digital
Refrigerant (Weight)
R290 (102g)
R290 (125g)
Rated Curent (A)
2.3
4.7
Rated Voltage (V)
220-240
220-240
Rated Frequency (Hz)
50
50
Product dimension
(WxDxH)(mm)
630×815×1950
1220×815×1950
Design and specification can change without prior notice to improve the quality of the
product. The illustration in this manual is schematic and can be different with your actual
product. The values on label or in other documents are according to laboratory test and
relevant standards. Values can vary depending on the actual operational and
environmental condition of the product.

12
MODEL
CC 2121 DASS
CC 2151 DASS
CC 3181 DASS
Type
Counter Chiller
Counter Chiller
Counter Chiller
Color
Stainless
Stainless
Stainless
No. of doors
2
2
3
No. of racks
2
2
3
Temperature range (°C)
-2 to +8
-2 to +8
-2 to +8
Capacity (Liter)
310
360
420
Power Input (Watt)
450
470
490
Defrost Power Input
(Watt)
235
235
235
Control panel
Digital
Digital
Digital
Refrigerant (Weight)
R290 (80g)
R290 (80g)
R290 (80g)
Rated Curent (A)
2.5
2.6
2.8
Rated Voltage (V)
220-240
220-240
220-240
Rated Frequency (Hz)
50
50
50
Product dimension
(WxDxH)(mm)
1200×750×850
1500×750×850
1800×750×850
Design and specification can change without prior notice to improve the quality of the
product. The illustration in this manual is schematic and can be different with your actual
product. The values on label or in other documents are according to laboratory test and
relevant standards. Values can vary depending on the actual operational and
environmental condition of the product.

13
MODEL
CF 2151 DASS
CF 3181 DASS
Type
Counter Freezer
Counter Freezer
Color
Stainless
Stainless
No. of doors
2
3
No. of racks
2
3
Temperature range (°C)
-22 to -18
-22 to -18
Capacity (Liter)
360
420
Power Input (Watt)
600
650
Defrost Power Input (Watt)
235
235
Control panel
Digital
Digital
Refrigerant (Weight)
R290 (100g)
R290 (100g)
Rated Curent (A)
3.8
4.0
Rated Voltage (V)
220-240
220-240
Rated Frequency (Hz)
50
50
Product dimension
(WxDxH)(mm)
1500×750×850
1800×750×850
Design and specification can change without prior notice to improve the quality of the
product. The illustration in this manual is schematic and can be different with your actual
product. The values on label or in other documents are according to laboratory test and
relevant standards. Values can vary depending on the actual operational and
environmental condition of the product.

05/23
PT MODENA INDONESIA
Jl. Industri Raya I Blok D-8,
Jatiuwung, Tangerang 15135
This manual suits for next models
8
Table of contents
Other Modena Commercial Food Equipment manuals