6
Press this button to save the new settings. The display will flash with the new value and will then
return to normal reading.
Alarm codes:
“P1‟ Flashing in the display: indicates that the cabinet sensor is defective.
The cabinet will strive to keep the set temperature until it has been repaired.
“P2‟ Flashing in the display: indicates that the evaporator sensor is defective.
This does not influence the operation of the cabinet, but should be repaired as soon as possible.
Defrosting
The cabinet defrosts automatically with pre-set intervals. If the door to the cabinet is opened or the contents of the
cabinet are changed frequently it may become necessary to defrost the cabinet manually.
Pressing this button continuously for more than 3 seconds will start a manual defrosting and then
return to normal operation.
Defrosted water runs to a container placed in the compressor compartment and evaporates.
Cleaning & maintenance
Disconnect the appliance from the socket.
The cabinet must be periodically cleaned. Clean the external and internal surfaces of the cabinet with a light soap
solution and wipe it dry. External surfaces can be maintained using steel oil.
Remove the condenser filter (see Picture 2.1), and clean it with a vacuum
cleaner and if necessary a light soap solution.
DO NOT use cleansers containing chlorine or other harsh cleansers, as these can
damage the stainless steel surfaces and the internal cooling system.
Clean the condenser and the compressor compartment using a vacuum cleaner
and a stiff brush.
DO NOT hose the compressor compartment with water as this can cause short
circuits and damage on the electrical parts.
Service
The cooling system is a firmly sealed system and does not require supervision, only cleaning. If the cabinet fails to
cool, check if the reason is a power outage.
If you cannot find the reason to the failure, please contact MODENA Call Center and inform model and serial
number of the cabinet which is placed inside the cabinet at the top right hand side.
Disposal
Disposal of the cabinet must take place in an environmentally correct way. Please note existing regulation on
disposal. There may be special requirements and conditions which must be followed.
Part 4: Cleaning & Maintenance