Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
1218CT0112 PP rev 04‑14‑2022
!
Failure to follow any or all of the warnings and instructions in this document could result in a hazardous liquid spill,
which could result in property damage, environmental contamination, re, explosion, serious injury or death.
Operation
WARNINGS
• Any modication of this unit beyond what is outlined in this instruction will void product warranty.
• For your safety, it is important to follow local, state, federal and/or OSHA rules that apply to working inside, above,
or around the storage tank and piping area. Use all personal protective equipment required for working in the specic
environment.
• Install in accordance with all applicable local, state, and federal regulations and codes.
• In the event of malfunction, remove from service immediately and contact Morrison Bros. Customer Service.
The 1218CT allows a Fuel Management System to query the 1218C Electronic Tank Gauge for current inventory. Inventory
changes are not reported to the FMS in real-time and must never be relied upon to prevent a tank overll.
IMPORTANT: The system operator must continuously monitor the 1218C Electronic Tank Gauge for tank level and
alarms to prevent tank overll. Refer to the 1218C Electronic Tank Gauge Installation, Operation, and Maintenance
Manual for more details.
Upon powering up the Communication Module all LEDs on the board will begin ashing for 5 seconds to check to see if a
rmware update is being initiated, then it will run the normal application.
Fuel Management System
Communication between the Communication
Module and the FMS will be initiated by the
FMS. The FMS will send a command to the
Communication Module, then it will reply
with data based on the command that was sent.
Supported commands are listed in Appendix A at
the end of this document.
1218C Console Communication
Communication status to the 1218C Console is
indicated to the user through the two LEDs D1
and D4, closest to the J2 connector, shown in
Figure 14.
• If the Green LED is ON and pulsing and the Red LED is OFF, this is an indication of successful
communication.
• If the Green LED is ON and the Red LED is blinking this indicates there is a communication error. Refer
back to the Communication Module Wiring section on page 7 to ensure wiring was completed correctly.
Firmware Update
Firmware updates to the Communication Module are initiated by loading the latest rmware from the Morrison
Brothers Co. website on to a USB drive. This drive is to be inserted into the USB port on the board, connector J6 in
Figure 10, and pressing and releasing the button on the board labeled ‘RESET’. The bootloader is congured to look
for a USB drive and update the rmware on power up.
Firmware Revert
Reverting the rmware on the Communication Module should be understood to be a last resort measure in the event
that the current rmware is not functioning correctly. Before the revert process can begin, ensure any USB drive is
removed from the USB port. Reverting the rmware is initiated by pressing and holding SW3 while pressing and
releasing the RESET (SW2). Once the RESET button has been pressed, continue to hold SW3 until the Green LEDs
start ashing. This will indicate that the revert process has begun.
!
Figure 14: LED location, 1218C communication