1
Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
419EG‑0203 PP
rev. 3-30-2022
!
!
!
Failure to follow any or all of the warnings may render the part nonfunctional and could result in a
hazardous product spill, which may result in property damage, environmental contamination, re,
explosion, injury or death.
Installation
WARNINGS
•Fire Hazard—Death or serious injury could result from spilled liquids.
• Any modication to this product other than stated in these installation instructions will void the product
warranty.
• Install in accordance with all applicable local, state, and federal laws.
• For your safety, it is important to follow local, state, federal and/or OSHA rules that apply to working inside,
above, or around the storage tank and piping area. Use all personal protective equipment required for working
in the specic environment.
• Tanks could be under pressure. Vapors could be expelled from tank vents, piping, valves or ttings while
performing installation. Vapors could catch re or cause an explosion. Avoid sparks, open ame, or hot tools
when working on tanks.
• Fill points should be labeled to identify product being transferred, according to all applicable codes.
• In the event of malfunction, contact Morrison Bros. Co. customer service.
Steps
1. Ensure Extender is being used on Morrison 2” drop tube.
2. Locate Extender Tool (see Figure 1).
3. Make sure the ends of the drop tube sections are cut square.
4. Locate installation template sticker and follow steps 1-8 listed on template (see Figure 2). When applying
label ensure both cut ends are butted together inline and square (see Figure 3). The QR code on template
includes a supplemental installation video if needed.
5. Before installing in the tank opening, check the drop tubes and connection for any bends or internal
blockages. If any are noticed, you may need to replace the drop tubes or remove blockage before proceeding.
Maintenance
This product should be maintained according to local codes.
WARNINGS
•Fire Hazard – Death or serious injury could result from spilled liquids.
• You must be trained to maintain this product. Stop now if you have not been trained.
• For your safety, it is important to follow local, state, federal and/or OSHA rules that apply to working inside,
above, or around the storage tank and piping area. Use all personal protective equipment required for working
in the specic environment.
• Tanks could be under pressure. Vapors could be expelled from tank vents, piping, valves or ttings while
performing maintenance. Vapors could catch re or cause an explosion. Avoid sparks, open ame, or hot tools
when working on tanks and tank accessories.
419EG Drop Tube Extender for 2” Drop Tube
for Gauging Applications
Installation & Maintenance Instructions
2
Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
419EG‑0203 PP
rev. 3-30-2022
Figure 1
5Clamp the 419EGT installation tool onto template, aligning top edge of tool with this line.
Ensure vertical line A is visible through notch in tool.
Turn each threaded forming screw until
it bottoms out, dimpling the sleeve. Then loosen
screws and remove clamp.
6
7Clamp the 419EGT installation tool onto template, aligning top edge of tool with this line.
Ensure vertical line B is visible through notch in tool.
Turn each threaded forming screw until
it bottoms out, dimpling the sleeve. Then loosen
screws and remove clamp.
8
Scan QR code for
installation video.
Peel backing off sticker.
1
Align top and bottom tube ends
to this line.
Roll sticker onto tubes.
2
START
HERE
Drill .25″ diameter holes
(Center punch and pilot holes
recommended)
3
ASlide 419EG sleeve onto template, positioned between dashed lines.
4
B
(then follow the numbered steps)
FOR ILLUSTRATION ONLY
Figure 2
Figure 3

Popular Extender manuals by other brands

Xinje XD Series manual

Xinje

Xinje XD Series manual

ADDER ALGTX Installation & use

ADDER

ADDER ALGTX Installation & use

Gefen EXT-VGARS232-141 user manual

Gefen

Gefen EXT-VGARS232-141 user manual

Gefen USB-400 user manual

Gefen

Gefen USB-400 user manual

LEGRAND C2G RapidRun 60218 quick start guide

LEGRAND

LEGRAND C2G RapidRun 60218 quick start guide

TECH Sinum EX-S1m quick start guide

TECH

TECH Sinum EX-S1m quick start guide

Atlona AT-HD4-SI40SR user manual

Atlona

Atlona AT-HD4-SI40SR user manual

Motorola SIGNAL BOOSTER - WARRANTY Limited warranty

Motorola

Motorola SIGNAL BOOSTER - WARRANTY Limited warranty

Wavlink WL-WN579A3 quick start guide

Wavlink

Wavlink WL-WN579A3 quick start guide

Westermo Wolverine DDW-142-12VDC-BP user guide

Westermo

Westermo Wolverine DDW-142-12VDC-BP user guide

Shinybow USA SB-6135R instruction manual

Shinybow USA

Shinybow USA SB-6135R instruction manual

CYP PU-232 Operation manual

CYP

CYP PU-232 Operation manual

HiBoost Smart Link Series installation guide

HiBoost

HiBoost Smart Link Series installation guide

British Sky Wireless Booster Setup guide

British Sky

British Sky Wireless Booster Setup guide

MSH CX300 User and installation guide

MSH

MSH CX300 User and installation guide

IOGear GCE500U installation guide

IOGear

IOGear GCE500U installation guide

Amped Wireless B1900EX Setup guide

Amped Wireless

Amped Wireless B1900EX Setup guide

Intelix DIGI?HD?COAX installation manual

Intelix

Intelix DIGI?HD?COAX installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.