Motorola MTSST9N0N01 User manual

24-disks MVMS Storage Server
Model: MTSST9N0N01
User Guide
Please read this instruction guide carefully before using the product and keep it for further reference.

Notes
Any updates will be added into the new version of this manual. The contents of this manual are
subject to change without notice.
This manual is suitable for the 24-disk storage server. All the images are to be used as references.
The storage server is mainly used with our MVMS software. This document is only a guide for the
system setup. Please refer to the storage server chapter in our MVMS software User Guide for
additional functional information.

Contents
1 Installation ...............................................................................................................................1
1.1 Interfaces and Indicators......................................................................................................1
1.2 Rear Panel Introduction.......................................................................................................1
1.3 HDD Installation .................................................................................................................2
2 Default System Configuration ................................................................................................2
3 Web Client Configuration.......................................................................................................3
3.1 Login...................................................................................................................................3
3.2 Disk RAID ..........................................................................................................................3
3.3 Network Configuration........................................................................................................4
3.4 Server Port Configuration....................................................................................................5
3.5 Change Password ................................................................................................................6
3.6 Basic Information................................................................................................................6
3.7 Date & Time........................................................................................................................6
3.8 Upgrade...............................................................................................................................7
3.9 Device Reboot.....................................................................................................................7
4 Questions & Answers...............................................................................................................7
5 Specifications ...........................................................................................................................8
Appendix Device Installation.......................................................................................................10

MVMS Storage Server User Manual
1
1Installation
1.1 Interfaces and Indicators
The icons below are for reference only. Please refer to the interfaces and indicators of your
actual server.
Icon
Description
Icon
Description
Power Key
System disk running indicator; flashing
green light indicators the disk works
normally.
Reset
Error Alarm indicator (including
system/fan/power error alarm)
USB interface
Network connection indicator. Green light
indicators the network connection is
normal.
1.2 Rear Panel Introduction
The following picture of rear panel is for reference only.

MVMS Storage Server User Manual
2
No.
Description
No.
Description
1
Redundant Power Connector
5
USB3.0 interface
2
Management interface
6
RJ45 interface
3
RS232 interface
7
VGA interface
4
USB2.0 interface
1.3 HDD Installation
① Press the blue button and then hold the casing to pull out the HDD case and then install the HDD
into the case.
②Fix the HDD by tightening the screws on both side of the case.
③Push the case with the HDD screwed in into the slot.
④Close the latch to fix casing in place.
2Default System Configuration
The default network configurations of the server are as follows:
IP Address: 192.168.0.10
Http Port: 8000
To avoid IP conflicts, it is recommended to configure one disk at a time as these storage
servers have the same default network configuration.

MVMS Storage Server User Manual
3
The default web management page: http://192.168.0.10:8000.
The default username is admin and the default password is also 123456.
The disks installed in one storage server used for RAID should be of the same brand, capacity,
rotate speed and buffer. The production batch should also try to be the same.
3Web Client Configuration
3.1 Login
The storage server is configured through web browser. It is recommended to use IE9 or above,
Firefox 51or lower or Google Chrome44 or lower or Opera35 or lower (We show IE browser in this
guide as an example).
Make sure the IP address of the computer is in the same local area network with the storage server
before accessing the storage server, or you will have to modify the IP address of the computer. For
instance, change the computer’s IP address to 192.168.0.100 and the gateway to 192.168.0.1.
Enter http://192.168.0.100:8000 in the IE address bar and then press enter to go to the login
interface as shown below.
Enter the username admin and password 123456 and then click “Login”button to go to the main
interface.
3.2 Disk RAID
Click “Disk Config”tab to go to Disk Configuration interface. Please click “Create”button to create
a disk RAID if you use the storage server for the first time.

MVMS Storage Server User Manual
4
Tips: It is recommended to create Raid5 and check hotspare disk for data security.
Click “Delete”button to pop up a confirmation dialog box. The created RAID will be deleted if you
click “Yes”button. Please be careful to delete the RAID because the record data stored in the RAID
will not be recovered once you delete the RAID.
3.3 Network Configuration
Click “Network Config”tab to go to the interface as shown below. The IP address, subnet mask and
gateway of the storage server can be set in the interface.
You will get a virtual IP address if the IP group is enabled. As to the access of the virtual IP address,
the operation system of the storage server will judge and transfer the access to eth0 or eth1
automatically.
For instance, if you disconnect the network cable of eth1 when testing “ping 192.168.0.10 –t”, you
will probably get a “Request Timeout”tip if you ping 192.168.0.10; and then you can probably ping
it successfully after a few seconds.

MVMS Storage Server User Manual
5
3.4 Server Port Configuration
Click “Port Config”tab to go to the interface as shown below.
Media Transfer Server port: the default number is 6006.
Auto Report Port: the default number is 2009.
Storage server port: the default number is 6009.
The above-mentioned ports can be modified and enabled as needed.

MVMS Storage Server User Manual
6
3.5 Change Password
For safety consideration, it’s strongly recommended to modify the default administrator’s username
and password if you access the storage server for the first time. Click “User Config”tab to go to the
interface as shown below. You can modify the username. For your security, please set a strong
password.
3.6 Basic Information
Click “System Maintenance”“Device Basic Information”to view the basic information of the
storage server (like product mode, firmware version, software version, etc).
3.7 Date & Time
It is recommended to set date and time first if you set the storage server for the first time. Click
“Date and Time”tab to go to the interface as shown below.
Select the time zone according to the region. For example, if you are in London, select GMT.
Synchronous Mode: auto or manual can be selected. Please set the system time manually or
automatically.

MVMS Storage Server User Manual
7
3.8 Upgrade
You can upgrade the storage server when there is a new software version available. Get the upgrade
software from your distributor, click System Maintenance Device Upgrade to go to the interface as
shown below. Click “Browse”button to select the upgrade file and then click “Upgrade”button to
start upgrading.
3.9 Device Reboot
Click System Maintenance Device Reboot to go to the interface as shown below.
Click “Device Reboot”to reboot the device.
4Questions & Answers
Q1. When the storage server is being started it shows “A discovery error has occurred, please
power cycle the system and all the enclosures attached to this system”.
A1. It indicates that the RAID card could not finish searching in 120 seconds. The system’s SAS
cable may be wrong connected. Please check the cable connection and repair the problems. Then
restart the system later.
Q2. It takes a very long time to rebuild the RAID.
A2. RAID rebuilding time depends on RAID size and the rebuilding process may take more than ten
hours. Recording and playback will not be affected when rebuilding.
Q3. How to replace the abnormal disks in the RAID?
A4. The corresponding disk status indicator will turn red in the disk RAID interface if the disk in the
RAID is abnormal. Uninstall the abnormal disk in the storage server case and then refresh the

MVMS Storage Server User Manual
8
interface; install a new disk after the disk indicator disappears. The RAID will rebuild automatically
later.
5Specifications
Model 24-Disk Storage Server
CPU Intel Xeon Processor E3
Chipset Intel C232 chipset
OS CentOS 7.3
Memory 8GB DDR4 ECC, up to 64GB DDR4-1866/2133MHz ECC memory
HDD 3.5 inch SATA slot×24(hot-pluggable);built-in 2.5 inch SATA slot×2
HDD installation Independent HDD bracket
Capacity Up to 192TB
RAID Hardware RAID; support RAID 0,1,5,6
Expansion 1*PCI-E3.0x16(×8);1*PCI-E3.0*8;1*PCE-E3.0*8(×4)
Network Card Integrated I210-AT dual gigabit network cards, load balancing and if one is
offline, the other will replace.
IPMI ASPEED AST2400 BMC, independent IPMI interface; support iKVM
Monitor Control Integrated display controller
Protocol Support to get video or audio streams of IPC by TCP/ UDP / RTSP protocol
Search Built-in index, accurate to second-level
Performance Up to 900Mbps access and storage
Up to 800Mbps access, 800Mbps storage and 96Mbps playback
Up to 800Mbps access, 800Mbps storage and 96Mbps live view
Way of Management WEB management, seamless access to MVMS
Capability of
Management RAID management, record management, system log as well as alarm processing
Security Supply TPM interface, TPM Module installation supported
Interface 1×VGA、6×USB(4 in the real panel and 2 in the front panel), 2×RJ45, 1×IPMI,
1×RS232
Power Supply 800W 1+1reduandent power supply, 100~240V-10~5A /50~60Hz
Operating
Environment Working: 10°C to 35°C; standby: –40°C~+55°C(ambient)
Relative Humidity Working: < 90% RH(35℃)
Noise Working: <50Dba
ESD Each item conforms to Intel ambient temperature test standard 15KV

MVMS Storage Server User Manual
9
Appendix Device Installation
Manufactured, distributed or sold by MDX Electronics, LLC, official licensee for this product. MOTOROLA and the Stylized M Logo are
trademarks or registered trademarks of Motorola Trademark Holdings, LLC and are used under license. All other trademarks are the
property of their respective owners. © 2021 Motorola Mobility LLC.
All rights reserved.
v1
Table of contents
Other Motorola Server manuals