Movacolor MC12-Micro User manual

MC12-Micro
Software version : V1.08
Manual revision : v01
Language : English
Date : February 2019

2
MC12 manual
Index
1 Introduction 3
Symbols 3
Terms 3
Transport 3
Receipt 3
Disclaimer 3
2 General information 4
Safety 4
Certification 4
Operating environmental conditions 4
3 Overview Dosing unit 5
MC12-Micro Components overview. 5
4 Installation 6
Mechanical Installation 6
Electrical Connections 7
Input (start) signal 7
5 Metering principle 8
6 Operation 9
The Interface 9
General 9
Start up 10
Configuration 10
Alarms / Warnings 11
Keyboard lock 11
7 Maintenance 12
8 System performance 13
APPENDIX A: MC12-Micro Technical Specifications 14
APPENDIX B: MC12-Micro Wiring Diagram 15
APPENDIX C: MC12-Micro Dimensional Drawings 16
APPENDIX D: Declaration of Conformity 17

3
MC12 manual
1Introduction
Thank you for purchasing a Movacolor metering device. This manual is addressed to operators and
qualified technicians taking care of the metering of dry additives to ensure correct use of the Movacolor
dosing unit.
Important note: this manual must be read before installing the dosing unit. Keep this manual in a place accessible for all operators.
Symbols
Important note
Attention; safety regulations for the operator
Terms
Operator: A person charged to operate, adjust, maintain and clean the machine.
Qualified Technician: A specialized, suitable trained person authorized to execute the installation,
non-routine maintenance, or repairs requiring special knowledge of the
machine and how it operates.
Transport
To protect the Movacolor unit against damage during transport, the unit is packed in a cardboard box filled
with polyurethane foam. Delivery terms are Ex-Works Sneek, The Netherlands. Buyer is responsible for the
transport. Movacolor cannot be held liable for any damage during transport.
Receipt
Check the unit thoroughly upon receipt. Pass any remarks to the local agent or Movacolor within 8 days
upon receipt of goods.
Disclaimer
Movacolor does not warrant that the hardware or software will work properly in all environments and
applications, and makes no warranty and representation, either implied or expressed, with respect to the
quality, performance, merchantability or fitness for a particular purpose.
Movacolor has made every effort to ensure that this user’s manual is accurate; Movacolor disclaims liability
for any inaccuracies or omissions that may have occurred.
Information in this user’s manual is subject to change without notice and does not represent a commitment
on the part of Movacolor. Movacolor assumes no responsibility for any inaccuracies that may be contained
in this user’s manual. Movacolor makes no commitment to update or keep the current information in this
user’s manual, and reserves the right to make improvements to this user’s manual and/or to the products
described in this user’s manual, at any time without notice.
If you find information in this manual that is incorrect, misleading or incomplete, we would appreciate your
comments and suggestions.

4
MC12 manual
2General information
Safety
The equipment is only designed and may only be used for the dosing of dry additives.
Any use that is not in conformity with the instructions is considered improper and as such frees
the manufacturer from any liability regarding damage to things and/or persons.
Before switching on the unit for the first time, ensure that the mains power voltage
applied is between 80 and 260VAC.
Always switch off the Movacolor control cabinet and disconnect the mains power plug from
electrical power before performing maintenance.
Ensure that all parts are securely fixed to the extruder or injection molding machine.
Dangerous voltages are present inside the control cabinet for up to 2 minutes after it has been
switched off.
Certification
The Movacolor dosing unit is designed and produced in conformity with the following European
regulations:
1. standards for machinery (health, safety, environment)
2. EMC (electromagnetic compatibility)
3. 2006/42/EG
4. RoHS
Operating environmental conditions
1. The unit must be protected against weather conditions
2. Operating temperature -20 to +70 degrees Celsius
3. Protection class: IP-50

5
MC12 manual
Motor connector
Motor
Motor spacer
Seal
Dosing house
Dosing Auger
Dosing tube
Hopper
Hopper cap
3Overview Dosing unit
MC12-Micro Components overview.
MC12 controller

6
MC12 manual
4Installation
Mechanical Installation
Most mechanical parts are pre-assembled, making installation quick and simple.
1. When installing a foreign main material hopper on top of a neckpiece, the top flange of the neckpiece
needs to be adapted. The lid of the neckpiece can be dismounted for easy machining.
2.
•Install the neckpiece directly on top of the
entrance of the production machine;
•Install the neckpiece in a 90-degree angle
to the machine barrel. This will optimize the
dosing accuracy in relation to vibrations of
the production machine;
•Make sure that the complete unit is mounted;
•horizontally levelled and fixed securely;
•Assure proper grounding to control cabinet,
neckpiece and dosing unit.
3. Connect the unit to the neckpiece by closing curled knob
clockwise.
Mount the unit in a 90-degree
angle to the machine barrel,
as shown in the picture.
Horizontally leveled (MCMicro
with 500ml hopper).

7
MC12 manual
Electrical Connections
The MC12-Micro controller is standard equipped with 3 connections:
1. Mains power cable,
2. Input cable
3. Motor cable
Before switching on the unit for the first time, ensure the mains power voltage being applied is between 80 and 260Vac.
Input (start) signal
The MC12-Micro needs an input signal from the production machine in order to operate.
Two different input signals can be used to control the dosing unit.
1. A potential free relay contact: Use the white and brown wire for the potential free contact.
2. A relay signal up to 24 Volt DC: Relay signals can be used for an extruder that has not a tacho signal. In
case of a powered relay signal connect the white wire to +24 VDC and the yellow wire to - side.
Also please have a look at APPENDIX B: MC12-Micro Wiring Diagram.

8
MC12 manual
5Metering principle
The Dosing Cylinder® of Movacolor combined with a very
precise adjustable stepping motor ensures that the additive
output is accurate and regular. For every particular application
Movacolor provides different neckpieces but the most common
mounting of the neckpiece is between the production machine
and the hopper. In the figure below a cut through of the NST40
neckpiece can be seen.
During operation, the virgin material runs from the
machine hopper through the neckpiece (1) into the
machine. Inside the neckpiece the virgin material flow (4)
is divided into two streams by the cover plate(3). In the
space below the cover plate, the rotating cylinder (2) is
dosing additive.
Additive is added directly into the center of the virgin
material flow, just before it enters the production
machine (5). This is a great advantage over metering devices
that use batch pre-mixing because pre-mixing can
actually cause material separation. Separation of
materials results in an irregular additive flow into the
production machine.
Fig. 3
1. Neckpiece
2. Movacolor dosing tool
3. Cover plate
4. Virgin material
5. To production machine

9
MC12 manual
6Operation
The Interface
General
•Connect motor before switching on the controller
•ALL changes has to be entered to acknowledge.
•A blinking value means the changed data is not acknowledged.
•To cancel a changed value, press the specific function button ( or ) again.
•Most functions have a designated key and LED on the interface. When a function is activated the LED
of that key/function will light up.
•All functions except the test function can be activated if the unit is started, (dependent on the
chosen configuration.)
•Only one of the following functions , , can be active at the same time. This means no other
function can be activated before the active function is deactivated
The unit can be set to different configurations, see paragraph 7.3.
Increase / Decrease value
Set dosing speed [RPM]
Set dosing time [sec.]
Start LED:
Blinking: motor
standby / waiting on
start signal.
Lighted continuously:
motor is running.
Start system
Stop system
Run test
Confirm value
Alarm LED
Input LED. Is lighted when
input connection is made.

10
MC12 manual
Start up
The MC12 software version is displayed shortly when the unit is switched on followed by the configuration
mode (con).
When the MC12 is set to configuration 2, the time function key is deactivated.
When a deactivated keys is pushed the unit will give a beeping signal.
For changing the unit configuration see paragraph 7.4.
Configuration
To make the configuration available,
keep speed and enter pressed while switching on the main power.
The configuration number will be displayed, press to switch between the possible configuration
and press to acknowledge. The software version will be displayed.
Timer
Timer mode is used for injection molding with a relay input signal. When the relay contact is made, the unit
will start dosing according the number of seconds that has been set with the time function.
Relay
A relay signal can be used in case working in extruder mode. With the relay input the unit will start dosing
when the relay contact is made and will stop when the relay is interrupted.
Speed and Timer
Speed and dosing time can be altered (time only in case of injection molding)
Speed = rotation of dosing system in RPM, (0,1 to 200 RPM)
Timer = time dosing system will rotate after start impulse, at input cable ( 0,1 to 999,9 sec)
Activate by pressing or , set the desired speed or time using press enter to
acknowledge
Configuration
Type of Production
Input signal
1
Injection Molding
Timer
2
Extrusion
Relay

11
MC12 manual
Production (Motor On/Off)
Press to start production. The function active LED will start blinking when the unit is waiting for an
input signal. The unit is dosing if the Start LED is lighted continuously.
Test (Material output), can only be used when unit is stopped
Test procedure to determine output of dosing system:
•Place dosing unit horizontally leveled (water level surface).
•Set the speed (and or) time (see settings)
•Press for Test
•Weigh the material dosed during test
•Adjust speed or time and repeat Test if necessary.
(Configuration 1): The unit will dose with the set speed and time.
(Configuration 2): The unit will dose for 30 seconds at the set speed
Emergency stop.
If the test is activated press stop to cancel a test.
Alarms / Warnings
Err0 : Motor connection failure.
Make sure the motor is connected
Check cable and connectors
Press to acknowledge the alarm.
Keyboard lock
+ + = Lock / Unlock,
Display shows : L.ON / L.OFF

12
MC12 manual
7Maintenance
To keep the MC12-Micro functioning correctly, it is advised to perform regular maintenance.
Always switch off the control cabinet and disconnect the mains power plug from electrical power
before performing maintenance.
Weekly
•Clean the dosing tool (cylinder or auger) for proper operation;
•Check dosing tool (cylinder or auger) for wear out. The rubber coupling of a dosing cylinder is a typical
wear out part;
•Check the dosing cylinder bearing for smooth rotating.
Monthly
•Check the motor seal for abnormal wear out.

13
MC12 manual
8System performance
The following variables may influence the accuracy and repeatability of the system:
1. Material properties. Easy flowing, non-sticky and non-static material that comes in the form of small
regular shaped granules or powder can be dosed very accurate and regular.
2. Periodical cleaning of the dosing cylinder and seals is necessary for proper operation.
3. Extreme vibrations and shocks can have negative influence on system performance.
4. An unstable relay signal has a negative influence on the repeatability.
5. With injection molding the shot to shot accuracy depends, besides the variables mentioned so far, on
the shot time in combination with granule size and weight. If relatively big and heavy granules have to
be dosed in a very short time, it will influence the shot accuracy and repeatability, because if only a
few granules are dosed during the shot, one granule more or less makes a big difference on the total
shot weight.
6. Vacuum or overpressure in the neckpiece caused by driers or hopper loaders.
7. Bridging or rat holing of the material inside the hopper can happen if the material is not free flowing.
8. Bridging or rat holing of the material inside the hopper can happen if the material is extremely static.
9. Extremely static material can contaminate the dosing cylinder.
10. In case of water cooled neckpiece, check if there is material build up around the dosing cylinder and
the water cooled pipe. Check also the water supply to the neckpiece.

14
MC12 manual
APPENDIX A: MC12-Micro Technical Specifications
Controls:
Speed:
Manual setting from 0,1 to 200 RPM max, in increments of 0.1 RPM.
Time:
Manual settings from 0,1 to 999,9 sec in increments of 0,1 sec.
Monitoring/System Information/External communication
Man/Machine interface: 4-piece 7 segments LED at front display.
External Communication: None.
Alarm:
LED Indication + Internal beeper.
Specifications/Standards & Directives/ Technical data:
Power supply: Operating power from 80 VAC to 260 VAC, 50 and 60 Hz.
by integrated automatic voltage selector.
Power consumption: 80 Watt maximum.
Stepper motor: (1,8degr/step) max 2 Amp at 40 Volt.
Operating Temperature: -20 to +70 degrees Celsius.
Input signal(s):
Injection molding: Start/Stop trigger input, potential free or 18-
24VDC*.
Extrusion: Start/Stop
trigger input, potential free or 18-24VDC*.
* Note potential contact Guaranteed OFF: 0-8VDC.
Guaranteed ON: 18-30VDC.
Output(s): Stepper motor
max. output 2A (40VDC).
Standard Directives: Protection class: IP-50.
Safety
•In case of overload due to short-circuit or in correct connection, the power supply automatically shuts
down;
•Opto-insulated start input for connection to production machine.
Machine connection flange:
Standard flange NST40 neckpiece with cleaning opening (steel epoxy coated);
Inlet: ø50mm;
Outlet: ø45mm.
Standard flange NST90 neckpiece with cleaning opening (steel epoxy coated);
Inlet: Ø50mm;
Outlet Ø90mm.
Optional parts
•12 liter hopper stainless steel;
•Water-cooled flange BH(A) inlet/outlet 50mm/50mm stainless steel ANSI 304;
•Water-cooled flange PHA inlet/outlet 100mm/100mm.

15
MC12 manual
APPENDIX B: MC12-Micro Wiring Diagram
To open the control cabinet use
the 4 bolts on the top and bottom
side, not the 6 bolts at the front
side.
WARNING
Do not make any adaptation to the
main board/components ore
warranty will lapse.
8
= Yellow
9
= Brown
10
= White
Potential free contact
Potential contact
[Min 18VDC to Max.24VDC]
Motor
Brown (1)
7
6
5
4
Coil 1
Coil 2
Yellow (2)
Green (3)
White (4)
Blue (N)
X5
Brown (L)
X4
Black (L)
X2
Black (N)
X3
Internal wires
Main power switch
3
2
Brown
1
PE
Western Europe
USA,Canada,Mexico,
Mid America,Japan,Taiwan
1 = Black
2 = White
3 = Green
N
L
Blue
Green/Yellow
Power Supply
-
+
10
8
9
+
10
IN
Input (start) signal

16
MC12 manual
APPENDIX C: MC12-Micro Dimensional Drawings

17
MC12 manual
APPENDIX D: Declaration of Conformity
DECLARATION OF CONFORMITY
(According to 2006/42/EC)
Manufacturer’s name :MOVACOLOR BV
Address :P.O. Box 3016
8600 DA Sneek
The Netherlands
www.movacolor.com
Declare under our sole responsibility that the products:
Product description : Dosing equipment
Product designation : MCBasic, MC12, MC18, MC30, MC12 Micro,
MC18 Micro, MCLiquidV, MCLiquidG,
MCHighOutputV, MCBalance.
Identification : From serial number 27500 onwards.
Year : 2019
-The object of the declaration described above is in conformity with the relevant Union
harmonization legislation;
Machine Directive 2006/42/EC
EMC Directive 2014/30/EU
RoHS 2011/65/EU
-The following harmonized standards and technical specifications have been applied:
EN 60204-1 Safety of machinery - Electrical equipment of
machines.
Part 1: General requirements
EN 61010-1:2010 Safety requirements for electrical equipment for
measurement, control and laboratory use.
Part 1: General requirements
Name: Gerhard Dersjant Place: Sneek the Netherlands
Position: Managing Director Date: May 2019
Signature:
Table of contents
Other Movacolor Industrial Equipment manuals