7. Connect the pump connector to the mating
connector.
6. Secure the five (5) screws on the condenser side panel, which were removed in procedure 3 on
page 2.
10. Secure the pump to the adapter plate.
Detailed procedure is as follows:
a) Insert the two (2) screws into the upper
holes of the adapter plate.
b) Slide the mounting slots of the pump over
the screws.
c) Secure the screws.
HOSE INSTALLATION
1. Pass the hose clamp through the inlet hose. Connect one end of the inlet hose to the drain stem
of the unit and secure with the hose clamp by removing the tab as shown.
2. Pass the other end of the inlet hose through the hole as shown and insert it into the pump inlet.
3. Unwind the outlet hose and connect to the drain outlet spout of the pump.
4. Pass the other end of the outlet hose through the knock-out hole in the lower service panel.
5. Reinstall the lower service panel to the unit.
Outlet Hose
Inlet Hose
Drain Stem
Pump Inlet
Outlet Spout
Hose Clamp
Remove Tab
Adapter Plate
Mounting Slot
Screws
2
Mounting Slot
Pump Connector Mating Connector