3
12 Volt Remote Trigger
This power supply is equipped with a remote trigger for use with other MSB
products. The trigger uses a headphone jack. When any MSB product is
turned off, the other products connected will also turn off and vice-versa.
The connector is wired as shown. If you connect “signal” to “ground”,
all MSB products will turn off. If you let the signal oat (12 V), all MSB
products will turn on.
Input Details and Ground Issues
A toggle switch by the inputs selects between three modes. The RCA and XLR are connected together.
The signal of the RCA input is connected to the non-inverted input of the XLR. The RCA case is
connected to the XLR inverted input.
The toggle switch changes the ground connections and gain as follows:
• Top position is the RCA mode. In this case the amp is in the normal gain mode. The RCA connector case is connected to
the AMP ground. This is the normal RCA input setting.
• Middle position is a special mode. The gain is still in the normal gain mode. The RCA connector case is NOT connected
to the XLR ground pin. This setting can be used with either the RCA or XLR input as follows. When the RCA input is
used, both the case and signal pins are oating. An external ground must be hooked up to the ground pin of the XLR. This
can be handy in solving some ground hum problems. If the XLR input is used, the gain is twice what one would expect.
This mode is handy when your output levels are very low.
• Lower position is the XLR mode. In this mode the ground connections are the same as the middle position but the output
is reduced by 6 db, making this the normal input mode for balanced inputs.
For best results, do not plug in both cables at the same time.
Warranty
All MSB products carry a one year warranty in the country of origin. No returns accepted without an RMA. Upon
receipt, MSB will repair or replace any defective product. All product shipped FOB Aptos. Shipping and shipping
damage is the responsibility of the consignee.
12 Volt Remote Trigger wiring.
If the signal is pulled low:
Unit will turn off.
If the signal is pulled down with a 50K resistor:
Unit will go to standby.
If the signal is left oating:
Unit will remain on.
If the signal is driven with 12 V:
Unit will turn on and switch will be ignored.
Power Supply LED Color Table
Green: The unit is on and operating
Amber: The switch for the unit is on, but the 12V trigger has turned it off, OR, the switch for the unit is on, but the protection
has shut if off because of overheating or over voltage.
Red: The switch is in the Off position.
Off: The switch for the unit is off but the 12 V trigger has turned the unit on, overriding the switch, OR, there is no power
due to a blown fuse or no power connection.
The M203 Amps are a key part of
a complete MSB system and can be
finished to match any color scheme.