MSD MM300 User manual

MM300 and MM100 Manual
REV01
Page 1 of 6

MM300 and MM100 Manual
REV01
Page 2 of 6
Contents
1Product definitions ...............................................................................................3
1.1 Introduction .........................................................................................................3
1.2 Principle...............................................................................................................3
2Wire Colors ..........................................................................................................4
3Technical data: .....................................................................................................4
4Safety precautions................................................................................................5
4.1 Milk meter MM300 and MM100............................................................................5
4.2 Foreword .............................................................................................................5
4.3 Disclaimer ............................................................................................................5
4.4 Safety regulations.................................................................................................5

MM300 and MM100 Manual
REV01
Page 3 of 6
1Product definitions
1.1 Introduction
The DeLaval milk meter MM300 (A) is an
electronicmilk meter designed to record the
milk yieldof cows; see Fig. 1.
It has no moving parts.
Electrodes for conductivity sensing are
positionedin the regulator sensor valve.
The cable between the milk meterand the
sensor is permanently sealed.
A fat sampler can be connected to the
meter, tocontinuously collect a proportional
amount ofmilk. The sample is included in
the measuredyield.
The MM300 is certified by ICAR for official
milk recording.
Fig. 1.DeLaval milk meter MM300
1.2 Principle
The MM300 comprises of an electric circuit
board and a short transparent pipe, which
enablesfree passage for the milk.
The optical sensors detect slices of milk
flowingthrough the channel. A high speed
processor inthe milk meter processes
100,000 measurementsper second.

MM300 and MM100 Manual
REV01
Page 4 of 6
These measurements are analyzed in order
toseparate milk slices. The following data is
calculatedfor each milk slice:
Length of milk slice
Speed
Acceleration
Air entry
Density
By analysing and computing the above
data,accurate milk flow and yield is
achieved.
3 Features
Measures milk flow
Measures yield
Detects blood*
Measures conductivity*
Measures Washing temperature*
Air leakage functions (kick-off*, block,
slip)
The functions marked (*) are only applicable
when the milk meter is connected DeLaval
milking point controllers.
2Wire Colors
Power Supply (+)
Ground
Input
Output
Brown
White
Purple
Blue
Power supply –connect to power supply (+)
Ground –connect to power supply (-)
Input –is current loop input
Output –is current loop output
All wires are protected according to CE marking.
3Technical data:
12-24 VDC +/-10%
Voltage supply
Average 4 W, Maximum 6 W
Power consumption
-10°C to +45°C (14°F - 113°F)
Working Temperature
-40°C to +75°C (-40°F - 167°F )
Storage Temperature

MM300 and MM100 Manual
REV01
Page 5 of 6
4Safety precautions
4.1 Milk meter MM300 and MM100
The Milk meter is design to be connect to limited power source with maximum voltage of
30VDC and 0.5 Amp.
4.2 Foreword
It is your responsibility to see that any personinvolved with the use or operation of this
equipmentfollows all safety and operational instructions.
Under no circumstances should you allowthis equipment to be used if the equipment
isfaulty or the operator does not completely understandthe operation of the equipment.
4.3 Disclaimer
The information, instructions and parts listed areapplicable and current on the date when
issued.DeLaval reserves the right to make changes withoutnotice.
4.4 Safety regulations
Caution!
Risk of damage, injury or electric
shock!
Never clean the equipment with ahigh-pressure cleaner or any otherjet of
water. The equipment is sensitiveand can be destroyed by thehigh
pressure.
Prohibited!
Never use solvents or alcohol on anypart of the equipment.
Failure tocomply can destroy or harm theequipment.
Mandatory!
Read the instructions carefullybefore using the equipment.
Contactyour local DeLaval dealer if there areparts of these instructions
that youdo not understand.
Compliance withthe instructions ensures a correctand safe use of the
equipment.
Savethe instructions for future reference.

MM300 and MM100 Manual
REV01
Page 6 of 6
This device FCC ID: AMUMM300
NOTE:This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and
c) Connect the equipment into and outlet on a circuit different from that to
which the receiver is connected.
d) Consult the dealer or an experienced radio/TV technician for help.
receiver.
Warning: Modifications not expressly approved by the manufacturer could
void the user's authority to operate the equipment under FCC Rules.
Warning:
SCR has not approved any changes or modifications to this device by the
user. Any changes or modifications could void the user’s authority to operate
the equipment.
This manual suits for next models
1
Other MSD Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

GF
GF Signet 8150 operating instructions

Kaiterra
Kaiterra Sensedge Mini Checklist

Bühler technologies
Bühler technologies Fluidcontrol BCM-MS Installation and operation instructions

Spectrum Technologies
Spectrum Technologies Field Scout TDR 350 product manual

Vaughan
Vaughan 050012 Safety

Aquila
Aquila T2 Mk III Taximeter user guide