MSTRONIC PSE-SW3B44DB User manual

USER’S MANUAL
MSTRONIC CO., LTD.
PSE-SW3B44DB
3 Port PoE Switch & Extender
(Repeat Ethernet and PoE)

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
2
1. General Information..............................................................
2. Hardware Description...........................................................
LED Indicators.......................................................................................
Power Wiring ........................................................................................
Ethernet Port Wiring..............................................................................
PD Port Wiring......................................................................................
Network Application……………………………………............................
3. Technical Specification........................................................
3
3
3
5
7
9
10
11

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
3
1. General Information
The PoE (Power Over Ethernet) Switch provide two 10M/100M/1000M TX ports with PoE PSE
function plus one 10M/100M/1000M TX up-link port with PoE PD function. It allow powered from
PoE power souring equipment (PSE) and deliver power to PoE powered device (PD), which is
compliant with IEEE802.3af ,IEEE802.3at and IEEE802.3bt standard to receiver and deliver both
of Ethernet data and DC power through the traditional UTP or STP cable. The PoE Switch can
extend Ethernet data and DC power up to 200 meters. This manual will help you install and
maintain the PoE switch. Installation of the PoE switch is very easy and you will begin to operate as
soon as you are powered up.
2. Hardware Description
*LED Indicator
There are 8 LEDs on the PoE switch to indicate the status of power and signal. The following
section describes the functions of each LED indicator.
Front panel detail

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
4
*POWER LED
LED
STATUS
Description
Power
Green
LED ON when power input (DC IN on
rear panel or port UP LINK on front
panel) has valid power supplied.
Red
The indicator unused on this model.
Off
No power supplied.
*SWITCH LED (the right indicator on RJ45)
LED
STATUS
Description
P1,P2&UP LINK
Link/Act
Green
A network device is detected (1000Mbps),
but no communication activity is detected.
Green
Blinking
This port is transmitting to, or receiving
package from another device at 1000Mbps.
Yellow
A network device is detected (10Mbps or
100Mbps), but no communication activity
is detected.
Yellow
Blinking
This port is transmitting to, or receiving
package from another device at 10Mbps or
100Mbps.
Off
No device is detected.

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
5
*PoE LED (the left indicator on RJ45)
P1,P2
PoE
Yellow
A valid Powered Device (PD) is detected
and delivering power via 4 data pairs on
this port.
Yellow
Blanking
A valid Powered Device (PD) is detected
and delivering power via 2 data pairs on
this port.
Off
No PD is detected on this port.
p
UP LINK
PoE
Yellow
Power via another PoE PSE(2 data pairs or
4 data pairs)
Off
No power is detected on this port.
*Power wiring
The PSE-SW3B44D4 is IEE802.3bt PoE switch, for PoE operation, make sure your power supply
may offer at least 40W for 2X 802.3af PoE ports, or 75W for 2X802.3at PoE ports, or 185W for 4X
802.3bt PoE ports. The input voltage must in the range of 44V to 57VDC if using for 802.3af
operation. The input voltage must in the range of 50V to 57VDC if using for 802.3at & 802.3bt
type 3 operation. The input voltage must in the range of 53V to 57VDC if using for 802.3bt type 4
operation.
The PoE switch PSE-SW3B44D4 allow powered by another PoE source on UPLINK as a PoE
repeater or extender.
If powered via the rear terminal, please make sure the input current is not over 10A. If powered on
UPLINK, make sure the input current is not over 2Amp.
The port 1&2 will deliver DC power over the Ethernet cable, the connection as:
* Data pair A plus V- on line 1 and 2
* Data pair B plus V+ on line 3 and 6
* Data pair C plus V+ on line 4 and 5
* Data pair D plus V- on line 7 and 8

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
6
The port UP LINK may get DC power over the Ethernet cable, the connection as:
* Data pair A plus V+ /V- on line 1 and 2
* Data pair B plus V-/V+ on line 3 and 6
* Data pair C plus V+/V- on line 4 and 5
* Data pair D plus V-/V+ on line 7 and 8
The terminal block on rear panel should be wiring as:

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
7
*Ethernet Port Wiring
The PoE switch family supports one RJ-45 uplink (port UP LINK with PoE PD) and two RJ-45
ports (port 1&2 with PoE PSE) with automatic MDI/MDI-X crossover, auto-sense the speed and
duplex for 10Base-T, 100Base-TX or 1000Base-T connection. Automatic MDI/MDI-X crossover
allows you to connect to other devices (switches, hubs, or workstations etc.), without regard to
using straight-through or crossover cabling.
Port 1 & Port 2 provides Power over Ethernet function that delivers DC power through the data
pairs(4 pairs or 2 pairs) to the PD. UPLINK port provides Power Device function that receive
power from 4 pairs or 2 pairs Ethernet cable.
The following tables describe the wiring diagram of straight-through and crossover cabling. That
crossover cables simply cross-connect the transmit lines at each end to the receive lines at the
opposite end.
Straight-through Cabling
Pin 1
Pin 1
Pin 2
Pin 2
Pin 3
Pin 3
Pin 6
Pin 6
Pin 4
Pin 4
Pin 5
Pin 5
Pin 7
Pin 7
Pin 8
Pin 8

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
8
Cross-over Cabling
Pin 1
Pin 3
Pin 2
Pin 6
Pin 3
Pin 1
Pin 6
Pin 2
Pin 4
Pin 7
Pin 5
Pin 8
Pin 7
Pin 4
Pin 8
Pin 8
Connect an Ethernet cable into any switch port and connect the other side to your
attached device. The Link/Act LED (green or yellow) will light up when the cable is correctly
connected. Refer to the LED Indicator section for descriptions of each LED indicator.
If a port LED is off, go back and check for connectivity problems between that port and the network
device connected.
The maximum cable length for 10/100/1000BaseT with Cat 5 twisted pair cables is typically 100m
(328 ft.).

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
9
*PD Port Wiring
Port 1 & 2 provide PoE inject function with maximum90W ability to power up the powered device
use the straight-through or cross-over Ethernet cable.
The PoE switch follows the IEEE802.3af Alternative A(MDI-X) + B mode connector assignment.
The following table shows pin assignment of alternative A and B for the Power Source Equipment.
Conductor
Alternative A
(MDI-X)
Alternative A
(MDI)
Alternative B
(All)
1
Negative Vport
Positive Vport
2
Negative Vport
Positive Vport
3
Positive Vport
Negative port
4
Positive Vport
5
Positive Vport
6
Positive Vport
NegativenVport
7
Negative Vport
8
Negative Vport
Be sure the twisted pair cable is bound with the standard RJ-45 pin. If the RJ-45 is bound with the
wrong pin number, PoE switch will not recognize the PD and won’t deliver DC power to PD. The
yellow PoE LED will light up when the cable is correctly connected. Refer to the LED Indicator
section for descriptions of each LED indicator. If a port LED is off, go back and check for
connectivity problems between that port and the network device connected.

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
10
*Network Application
The PoE Switch can receive power from PoE midspan and provide power to the PD which follows
the IEEE 802.3af/at standard in the network. The PoE Switch can be installed in a more appropriate
position for better performance to extend Ethernet to 200 meters. The following figure is an
example of a network application for PoE Switch.

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
11
3. Technical Specifications
Standards IEEE802.3/IEEE802.3u standards/IEEE802.3ab (10
base-T/100base-TX/1000base-T)
Ports 3 ports with PoE (2 PSE & 1 PD), support auto-crossover &
auto-polarity
Transmission speed 1000Mbps (1000base-T).100 Mbps (100base-TX), 10 Mbps(10base-T)
Auto-negotiation
Switch technology store-and-forward
Protocols CSMA/CD
Flow control IEEE802.3x (full-duplex), back pressure (half-duplex)
Data transmission rate 1488000pps for1000base-T, 148800pps for 100base-T, 14880pps for
10base-T
Address table 1K MAC address table, self-learning
Connect RJ-45
PoE port Port 1&2, PSE auto power management
*A+B mode: data pair AplusV-(1,2),data pair B plusV+(3,6),
data pair C plusV+(4,5), & data pair D plus V-(7,8)
Port UPLINK, 4 pairs PD
Maximum PoE output Port 1-2: IEEE802.3af –16.8W
IEEE802.3at –35W
IEEE802.3bt class 8 –90W
Maximum PoE input Port UPLINK: 71W (802.3bt class 8)

User’s Manual PSE-SW3B44DB
MSTRONIC CO., LTD.
12
PSE disconnect mode DC disconnect
PoE auto detection IEEE802.3af , IEEE802.3at (2 event classification) &
IEEE802.3bt(multi-event classification)
PoE protection Over-temperature, over-current, over/under voltage
LEDs *Link/Activity (Green ON/ Green Blinking @1000Mbps,
Yellow/Yellow Blinking @10M/100Mbps)
*PoE (Yellow) port 1-2 ON - PD detect, deliver power via 4 data ports
Blinking-PD detect, deliver power via 2 data ports
Port UPLINK ON –power via PoE PSE
*POWER Green-normal
Power input Port UP LINK from network switch or midspan, or option DC power
supply
Power consumption less than 5W when without PD loading
Operating temperature -20℃~+70℃
Operation humidity 90% relative humidity, non-condensing
Storage temperature -40℃~+85℃
Dimension 40mm(H)x116mm(W)x90mm(D) available for DIN RAIL Mounted