2
Please read these instructions carefully before use and retain for future reference.
• Avoiding exposure to extreme heat or cold, your scale works better when operated
at normal room temperature.
• Always allow the scale to acclimate to normal room temperature for at least 1 hour
before rst use.
• Allow sufcient warm up time. Usually 30 seconds to give the internal components
time to stabilize before calibration or use.
• Keep your scale in a clean environment. Dust, dirt, moisture, vibration, air currents
and a close proximity to other electronic equipment can all cause an adverse effect
on the reliability and accuracy of your scale.
• Handle with care. Gently apply all items to be weighed onto the tray top.
• Avoid shaking, dropping or otherwise shocking the scale. This is a precision
instrument and must be handled with extreme care.
• Only operate the scale on a stable, at, vibration free surface.
• Always remove the batteries if the scales are not to be used for long periods.
IMPORTANT SAFETY INFORMATION
WHAT’S INCLUDED
OPERATION
FUNCTIONS
• Balance Scales
• 2 x AAA Batteries
• Instruction manual.
• Calibration weight
TARE WEIGHING:
• Turn on scale as described above.
• Place the “tare item” (eg: empty container) on the platform.
• Press [TARE] and wait until “0.0” is displayed.
• Add the “net-weight-item” into the container and the screen will display the weight.
CALIBRATION
• Reset the scale by pressing [ON/OFF] key.
• Wait until the LCD displays “0.0” and then press and HOLD [MODE] key for 3
seconds.
• Place scale on a horizontal at surface.
• Press [ON/OFF] key to turn on the scale.
• Wait until the LCD displays “0.0”.
• Put the object(s) to be weighed on the weighing platform.
• Press the [MODE] key to switch between the weighing units.
• The scales will automatically turn off after about 3 minutes of inactivity.
• If the display shows “EEEE” it is overloaded - remove the excess load immediately
to avoid damage.
• If the display shows “LLLLL” the load cells may have been overloaded or the scales
shocked. If the cells are not seriously damaged recalibration may restore operation.
• If the display shows “OUT2” the scales need calibrating.