2
CONTENTS
1 Introduction ....................................... 2
2 Technical data ................................... 3
3 General information ........................... 6
4/5 Installation & Commissioning.............9
The MULTIFIT Advance & HeatSaver Systems are domestic hot water systems designed to provide a high level of
performance more efficiently.
The combination boiler will provide both central heating and domestic hot water at mains pressure.
The complete Advance package consists of a 40kW condensing combination boiler, GasSaver GS-1 22BV*,
Heatsaver Temporal Store Cylinder (50 litre), ‘Low Profile’ Flue Elbow, 8 litre expansion vessel and fittings kit. An 'S' plan
control system is also supplied. NOTE: No other control system should be used with the Advance or HeatSaver System.
When the 8 litre expansion vessel is fitted, total system volume can be up to 250 litres.
NOTE: The HeatSaver package DOES NOT include a condensing combination boiler or ‘Low Profile’ Flue Elbow. The boiler
and appropriate flue must be obtained separately.
*Design based on SuperFlow Technology by Zenex Technologies Ltd. and manufactured under licence. Zenex products
and technologies are protected under UK Patent Nos. 2420174 and 2451341 - Other patents pending.
The MULTIFIT Advance & HeatSaver Systems must be installed as detailed in these instructions. The boiler and GasSaver
must be installed in accordance with the installation instructions supplied with them. Failure to do so will negate the warranty
supplied with the package.
The Advance & HeatSaver Systems have been approved to the relevant requirements of the Building Regulations for primary
hot water storage systems and to the UK Water Regulations.
It is the law that all gas appliances are installed by a competent person in accordance with the following recommendations:-
Current Gas Safety (Installation and Use) Regulations.
All current Building Regulations issued by the Department of Communities and Local Government (CLG) i.e. Approved
Document L1.
Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Government Built Environment
Directorate - Building Standards Division.
UK Water Regulations/Byelaws (Scotland)
Health & Safety Document No. 635 (The Electricity At Work Regulations 1989)
The installation should also be in accordance with the following British Standard Codes of Practice:-
BS 5440:1:2000 Flues
BS 5449:1990 Forced circulation hot water systems
BS 5546:2000 Installation of hot water supplies for domestic purposes
BS 6700:1997 Design, installation, testing and maintenance of services supplying water
BS 6798:2000 Installation of gas fired hot water boilers
BS 6891:1998 Gas installation
BS 7593:1992 Code of Practice for treatment of water in heating systems
BS 7671:2001 Requirements for electrical installations, IEE Wiring Regulations
Failure to install any part of the Advance or HeatSaver System correctly could lead to prosecution. It is in your own interest
and that of safety to ensure that the law is complied with.
Manufacturer's instructions must NOT be taken in any way as over-riding statutory obligations.
It is essential that the primary system is thoroughly cleaned and flushed when fitting the Advance or HeatSaver System.
All cleaning agent must be removed and inhibitor added to the system - failure to do so will invalidate the warranty.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance
by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
6 Short parts list ................................... 10
7 Routine inspection .............................. 10
8 Inspection history ............................... 11
1.0 Introduction
The MULTIFIT Advance & HeatSaver Systems have been designed to deliver domestic hot water at a high level of performance
more efficiently, for example the Advance System can provide18 l/min at temperatures of 50°C and above for long periods of
demand using less energy than a typical hot water storage system utilising a large cylinder.
The cold water supply first passes through the GasSaver where the reclaimed heat from the hot flue gasses is used to
pre-heat the cold water supply. This pre-heated water then passes through the coil in the 50 litre temporal store where it
is heated to a higher temperature. This hot water is then delivered to the blending valve where it is mixed with water direct from
the cold mains supply and enters the cold inlet of the combination boiler at a temperature of approximately 30°C. The boiler then
heats the water to the required temperature.
System Operation
TM
IMPORTANT