8. Technical Specification
Model: 22-23001
Voltage: 230 V AC, +-10%, 50/60 Hz
Operating Performance: 230 V: 1,8 W
Temperature setback:
Temperature range:
2°C-4°C
5°C- 30°C
Span: +/- 0,5°C
Storage temperature: -20°C to +60°C
Ambient temperature: 0 °C up to 45 °C
Degree of protection:IP 30
CE conformity according to: Class II ( EN60730 )
Housing material:PC, V2
Color: RAL 9010 pure white
Connection: Screw terminal
Weight 90g net / 135g gross
Puls-wide-modulation:
(PWM) Yes
Valve protection:
Heating and Cooling:
Cooling blocked:
Dimensions:
Yes
Yes, automatically Change Over on the CO terminal
Yes, with jumper
85mm*85mm*25mm
Warranty
Multipipe warrants that this product (22-23001) will be free from any
defect in materials or workmanship, and shall perform in accordance with
its specification, for a period of five years from the date of installation.
Multipipe sole liability for breach of this warranty will be (at its option) to repair or
replace the defective product.
Customer Name: ......................................................................................................................................................
Customer Address: .................................................................................................................................................
............................................................................................................................................................................................
....................................................................................... Post Code: ...........................................................................
Tel No: .................................................................... Email: .......................................................................................
Engineers Company: ..........................................................................................................................................
Tel No: ...................................................................... Email: ....................................................................................
Instalation Date: ....................................................................................................................................................
Engineers Name: ...................................................................................................................................................
Engineers Signature: ...........................................................................................................................................
6. Protection Function
7. Control Patterns
5. Thermostat Functions
NSB (Night SetBack) Function
NSB Mode depends on the NSB wired connection.
0V = NSB OFF
230V= NSB ON
The NSB signal is activated every 1 second. When the signal is received the
setpoint temperature will be set at ±2°C or ±4°C.
Heating and Cooling Selection
The Heating/Cooling function is determined by the CO terminal connection.
CO 0V= Heat mode
CO 230V= Cool mode
Cooling Blocked function
Cooling Enabled:
Set the jumper on ON . The thermostat will run in normal cooling mode.
That means that it will open/close the actuators when necessary. The LED will be
BLUE when the cooling function is running.
Cooling Disabled:
Set the jumper on OFF . The actuator will be closed and the LED will
be off.
Heat cut o at high/low temperature:
When room temperature is over 36°C or under 4°C, all heating/cooling outputs
will be turned off.
Short cycle protection:
When Cooling Mode is enabled the minimum interval between Relay ON/OFF
is 3 minutes.
Valve Protection:
Set the jumper on‘ON’to disable the function or on‘OFF’ to enable it. Turn on the
valve for 5 minutes every week to prevent any damage to the valve.
Sensor Malfunction:
If the temperature sensor or temperature sensor compensation is open the LED
will flash BLUE/RED alternatively.
If CO terminal is connected and the Heating Mode is ON, the PWM function
will be activated.
If CO terminal is disconnected and the Cooling Mode is ON the ON/OFF control
output will be activated.
DIAL 230 V
THERMOSTAT
Model: 22-23001
INSTALLER MANUAL
Multipipe Ltd
Unit 12 Great Hayes Business Park
Lower Burnham Road
Stow Maries
Chelmsford, Essex, CM3 6SQ
Sales
T: 01245 227630
E: [email protected].uk
Technical
T: 01245 850799
E: [email protected].uk
www.multipipe.co.uk
Product Compliance & Safety Information
Product Compliance
Multipipe hereby declares that the product complies with the essential
requirements of the following EC Directives: 2014/30/EU, 2014/35/EU and
2011/65/EU.
Safety Information
Use in compliance with safety regulations. The unit is to be used for the control of
room temperature inside the house.
Installation
This accessory must be fitted by a competent person, and installation must
comply with the guidance, standards and regulations applicable to the city,
country or state where the product is installed. Failure to comply with the relevant
standards could lead to prosecution.
Note: All electrical installation work should be carried out by
a suitable qualified electrician or other competent person.
Product Description
Thank you for purchasing the Multipipe 22-23001 Thermostat. This thermostat
is a device that lets you customise the heating and cooling of your home as
needed.
The 22-23001 is an electronic room temperature controller which offers key
advantages over conventional mechanical products.
The controller is easy to operate using the conventional backlit adjusting dial
and offers you unique control convenience for heating applications of all types
thanks to the high quality device electronics. We hope you enjoy our product.
Contents of the box
Manual Contents:
Box Contents
Introduction
Product Compliance and
Safety Information
Installation
User Interface
Status/LED indication
Installers notes
Warranty
Icons used in this manual:
Safety
Important info
Your benefit
Fixing Screws
1 x Installer Manual
Thermostat
Gently remove front housing and
make the wiring connections.
2. Terminal Connection 4. Jumpers
1. Mounting the Thermostat 3. Switching Bridges
Note: You can wire the thermostat
directly to the 22-23013 Wiring
Center (purchased separately).
Wall mounting
For wall mounting, mark the correct
possition on the wall and mount the
rear case to the wall.
Install the 22-23001 dial room thermostat at roughly 1.5m above floor level. It
should be mounted in a location where the thermostat is easily accessible and
away from direct sunlight.
CO
N
L
ACTUATOR
30ºC
25
N
L
E.G.
HEAT
PUMP
EXTERNAL
CLOCK
230VAC
50Hz
CO
N
L
30ºC
25
Different features of the 22-23001
can be switched On or OFF with
the jumpers. In order to do this
please follow the table below.
22-23001 Switching Bridges
Switch
VP Valve protection feature
Pulse-Width-Modulation
NSB Function (2° or 4°)
Heating/Cooling
PWM
CO
Feature ON OFF
2°C
Enable Disable
4°C
The jumpers from 1 to 5 are representing the number of actuators that you can connect
to the thermostat.
After the actuators are mounted please move the jumper on the correct number (the
same as the number of actuators).
Depending on the amount of actuator used, please change the jumper position
accordingly to compensate the power consumption.
DIAL 230 V
THERMOSTAT
Model: 22-23001
INSTALLER MANUAL

Other Multipipe Thermostat manuals

Multipipe 22-23002 User manual

Multipipe

Multipipe 22-23002 User manual

Multipipe 22-02403 User manual

Multipipe

Multipipe 22-02403 User manual

Multipipe RIO QUANTUM 22-00006 User manual

Multipipe

Multipipe RIO QUANTUM 22-00006 User manual

Multipipe QUANTUM SQ610 User manual

Multipipe

Multipipe QUANTUM SQ610 User manual

Multipipe 22-00003 User guide

Multipipe

Multipipe 22-00003 User guide

Popular Thermostat manuals by other brands

Neptronic TFCB24F3XYZ1 Specification and installation instructions

Neptronic

Neptronic TFCB24F3XYZ1 Specification and installation instructions

greenmomit momit Smart user guide

greenmomit

greenmomit momit Smart user guide

meitav-tec ETNC24-SUPER-MDB-01 Owner's manual & technician settings

meitav-tec

meitav-tec ETNC24-SUPER-MDB-01 Owner's manual & technician settings

Stelpro STE302P user guide

Stelpro

Stelpro STE302P user guide

Bosch EasyControl CT200 Quick install guide

Bosch

Bosch EasyControl CT200 Quick install guide

Continal Quantum dial thermostat-RF quick guide

Continal

Continal Quantum dial thermostat-RF quick guide

OJ MTU2 Series instructions

OJ

OJ MTU2 Series instructions

VDH ALFA-45A user manual

VDH

VDH ALFA-45A user manual

Goodman G2270 Owner's Manual & Installation Instructions

Goodman

Goodman G2270 Owner's Manual & Installation Instructions

SmartDHOME MyVirtuoso Home Zone Thermostat user manual

SmartDHOME

SmartDHOME MyVirtuoso Home Zone Thermostat user manual

ClimateMaster iGate 2.0 quick start guide

ClimateMaster

ClimateMaster iGate 2.0 quick start guide

Heatit Z-TRM3 Installer manual

Heatit

Heatit Z-TRM3 Installer manual

ABB TC16-214 user guide

ABB

ABB TC16-214 user guide

Etherma Etouch hybrid Operating and assembly instructions

Etherma

Etherma Etouch hybrid Operating and assembly instructions

QUBINO FLUSH ON/OFF THERMOSTAT 2 quick start

QUBINO

QUBINO FLUSH ON/OFF THERMOSTAT 2 quick start

Honeywell PRO 2000 Series operating manual

Honeywell

Honeywell PRO 2000 Series operating manual

Heatmiser DT operating instructions

Heatmiser

Heatmiser DT operating instructions

Atwood Hydro Flame 1H2C Installation & operation manual

Atwood

Atwood Hydro Flame 1H2C Installation & operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.