DCA400SSV
WhisperWatt
TM
Generator
Specifications
Warranty*
Volvo Engine
24 months from date of purchase with unlimited hours.
Generator
24 months from date of purchase or 2000 hours (whichever occurs
first).
Trailer
12 months excluding normal wear items.
*Refer to the express written, one-year limited warranty sheet for additional
information.
Generator Specifications
Design Revolving field, Self-ventilated
Drip-proof, Single bearing
No. of Poles 4-pole
Excitation Brushless with AVR
Standby Output 352 KW (440 KVA)
Prime Output 320 KW (400 KVA)
Generator RPM 1800
Voltage — 3Ø 208, 220, 240, 415, 440, 480V
Reconnectable
Voltage — 1Ø 120, 127, 139, 240, 254, 277V Adjustable
Armature Connection Star with neutral
Voltage Regulation
(No load to full load) ±0.5%
Power Factor 0.8
Frequency 60 Hz
Frequency Regulation:
No Load to Full Load
Isochronous under varying loads from
no load to 100% rated load
Frequency Regulation:
Steady State
±0.25% of mean value for constant loads
from no load to full load
Insulation Class F
Sound Level dB(A)
Full load at 23 feet 72
Engine Specifications
Make / Model Volvo / TAD1241GE
Emissions EPA Tier 2 Certified
Starting System Electric
Design
4-cycle, water cooled,
Direct Injection, turbocharged,
air to air Intercooled
Displacement 12,130 cc
No. cylinders 6
Bore x Stroke (mm) 131 x 150
Gross Engine Power Output 534 bhp (398 kWm)
BMEP 286 psi (1,970 kPa)
Piston Speed 1,776 ft./min. (9.02 m/s)
Compression Ratio 17.5 : 1
Engine Speed 1800 rpm
Overspeed Limit 2100 rpm
Oil capacity gallons (liters) 9.2 gal. (35 liters)
Battery 12V 150Ah x 2 (24V System)
Fuel System
Maximum Fuel Flow (per hour) 145 gallons (549 liters)
Maximum Inlet Restriction (Hg) 4.8 in. (122 mm)
Fuel Tank Capacity 129 gallons (490 liters)
Fuel Consumption gph lph
At full load
At 3/4 load
At 1/2 load
At 1/4 load
20.6
15.4
10.8
6.3
78.1
58.3
41.0
23.7
Cooling System
Fan Load 15 HP (20 KW)
Coolant Capacity (with radiator) 11.6 gallons (44 liters)
Coolant Flow Rate (per minute) 95 gallons (360 liters)
Heat Rejection to Coolant (per minute) 8,132 Btu (8.56 MJ)
Heat Rejection to Engine (per minute) 2,625 Btu (2.77 MJ)
Maximum Coolant Friction Head 8.7 psi (60 kPa)
Maximum Coolant Static Head 16.74 feet (5.1 meters)
Ambient Temperature Rating 95°F (35°C)
Air
Combustion Air 1,024 cfm (29.0 m3/min)
Maximum Air Cleaner Restriction 8 in. H2O (2.0 kPa)
Alternator Cooling Air 2,797 cfm (79.0 m3/min)
Radiator Cooling Air 13,771 cfm (399 m3/min)
Exhaust System
Gas Flow (full load) 2,543 cfm (72.0 m3/min)
Gas Temperature 914°F (490°C)
Maximum Back Pressure 40.2 in. H2O (10 kPa)
Amperage
Rated Voltage Maximum Amps
1Ø 120 Volt 888.9 Amps (4 wire)
1Ø 240 Volt 444.4 Amps (4 wire)
3Ø 240 Volt 962.3 Amps
3Ø 480 Volt 481.1 Amps
Main Line Circuit Breaker Rating 1000 Amps
Over Current Relay Trip Set Point 480 Amps
Generator is not intended for use in enclosed areas or where free flow of air is restricted.
Backfeed to a utility system can cause electrocution and/or property damage. Do not
connect to any building’s electrical system except through an approved device.
Specifications are subject to change without notice.
DCA400SSV Rev 5