6
7. Piping
Use rubber sleevesor flexible joints to connect to piping to avoidunnecessary force to the blower and
to isolate thevibration from the blower. If direct connection to piping is inevitable, do not give the force
to the blowerby dimensionaltolerances,weightofpiping,thermalexpansion ofpiping,etc.
8. Connection to Powerand Test run
(1) Turn the fanby hand to verify freerotationwithout rubbing ornoise.
(2) Check the nameplates of blowerand motor and confirm if they agree with the specification for
power supply,then connect to powerlineunderinstruction byelectrical engineer as per electric
technical standards andwiring regulation.
(3) Jog the blower and confirm the rotational direction is the same as the mark. If the rotational
direction is opposite, change the wiring connection. The direction can be reversed by
exchanging 2 wires of 3 wires. If the blower runs continuously with reverse rotational direction,
itcannotperformasspecifiedandmaylead toseriousaccident.
(4) Runtheblowerand measure the electriccurrent (average of each of3phase)of themotor.If it
exceeds the rated current, use at below the rated current by adjusting the air volume with
damper and so on. After running for a while, if there is no abnormal vibration or noise, test run
can be concluded. If any abnormality were found during test run, corrective action should be
takenby referring to “11. Troubleshooting”.
9. Precautions for Operation
Beforeoperating the blower,understand the following thoroughly.
(1) Continuoususe atsmallairvolumewillleadto blowerdurabilityproblem.
(2) The blower is designed to handle clean air. It cannot handle for air containing particulates and
dust, corrosive gases nor inflammable gases. Temperatures of air which standard model can
handle areintherangeof-15 to 50deg.C.
Pay attentiontofollowingprecautionincaseofthatheatresistantmodeloperate.
(3) Donotwrapthecoolingfan coverina heatinsulationmaterial.
Otherwise the life of the motor bearing may be shortened because the heat insulator material
prevents heatloss.
(4) After starting the blower, temperature of the gas should be raised slowly. Otherwise the blower
maybestrained byheatexpansion.
(5) When stopping the blower, keep running it until the temperature of the blower becomes nearly
room temperature. If the blower stops suddenly, the motor may be broken because the heat is
transmitted to it.