Condensate pump for A/C
8. Trobleshooting
1.Installation is not
horizontal
2.There is sludge inside
tank
Clean the inside of tank and
float
1.The water is siphoning
back in the pump
Check whether the outlet pip
eis lower then pump thus
result in siphoning, raise the
condensate pump position
1.Installation is not
horizontal
Adjust the tank, check water
level
2.The power can’t reach
pump
3.The voltage isn’t
correct
Check power supply voltage
9. Important service guide
Every six months or more often, the tank should be removed, cleaned, and
cleaned also the filter and float. We recommend this at the spring, and in the
autumn, using anti-bacterial wash chemically. Take a care to replace the float
with magnet facing up.