Naked NKD1 Assembly instructions

Installation and Setup Guide

1. IMPORTANT WARNINGS & SAFETY INSTRUCTIONS
1.1 Important Warnings
1.2 Important Safety Instructions
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner and/or operator of this equipment. When
installing and using this electrical equipment, basic safety precautions should always be followed.
Failure to follow safety warnings and instructions in this manual can result in serious injury and/or
damage to your equipment. Read and follow all warning notices and instructions which are
included in this manual.
The Control Unit internally contains live components. There is a danger of electric shock if opened. If
the power cord is damaged then it should be replaced by the manufacturer, their agent or similar
qualied person, in order to avoid a hazard. The product shall be installed according to AS/NZS 3000
wiring rules. It shall be installed outside the pool zone. Please contact Naked Pools on 1300 625 331
for further assistance.
To reduce the risk of injury, do not permit young children to use this product unless they have been
trained by the person responsible for their safety and they acknowledge their ability to use such
equipment. To reduce the risk of accidents or incidents, service on the unit should only be
performed by a qualied pool service professional.
When mixing acid with water, ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO ACID.
DO NOT PLUG UNIT IN IF CARTON HAS BEEN WET.
GAS BUILDUP CAN OCCUR WITH IMPROPER WIRING: To reduce the risk of personal injury, the
Control Unit is designed so that the OXI Cell and ION Rods will only receive power when the pool
pump is on. Otherwise possible gas build-up can occur. If the pump is not installed to the AC Socket
(pump outlet) on the Control Unit, the installer must ensure that the OXI Cell and ION Rods are never
energised when the pool pump is OFF or water is not owing through the unit.
www.naked-pools.com
4

2. GENERAL OVERVIEW
Congratulations on the purchase of your NKD1 Fresh Water System. Please take a moment to read through
the entire manual before installing your new unit. Your system must be installed and operated as
specied.
While every effort has been made to ensure that the information contained in this guide is accurate and complete,
no liability can be accepted for any errors or omissions. Naked Pools Pty Ltd reserves the right to change the
specications of the hardware and software described herein at any time without prior notice.
Your NKD1 Fresh Water System is a true environmentally friendly system requiring far less maintenance than
traditional sanitisers. This hybrid swimming pool and spa sanitisation system uses a combination of copper and
silver ionisation as well as oxidation to treat and provide fresh water. This delivers up to 70% less salt/mineral levels
than its rivals, resulting in record low levels of chlorine being produced.
Please remember that your NKD1 Fresh Water System is not designed to chemically maintain your pool water and
keep it balanced. We encourage regular water and copper testing, balancing and correction if & when required to
maintain the recommended balanced levels of your pool water. This is a vital part of a complete maintenance
program and will ensure a trouble-free fresh water pool.
There is one design in our Naked Pools Fresh Water System range:
NKD1 is designed to optimally sanitise swimming pools up to and including 100,000L of water. Smart self-cleaning
technology allows the polarity of the OXI Cell plates to change direction every 4-16hrs (depending on your
setting). Reversing times can be changed, see 7.3 CELL CLEANING. The change of polarity causes the calcium to
dislodge and keep the OXI plates clean. Please note occasional cleaning of the plates may be necessary.
The ION Rods change direction every 3 minutes to ensure even wear and tear.
Please note the Rods are sacricial and will have to be changed from time to time (typically every 2 years)
depending on the size of your swimming pool.
Visit www.naked-pools.com or call 1800 NAKED1 (625 331) for further information.
2.1 Recommendations and Helpful Hints
• Read and keep your manual in a safe place.
• Operate the unit on manual when large number of swimmers are present to ensure sufficient water
turnover.
• Maintain your copper level between 0.2-0.4ppm at all times.
• Check your copper levels weekly with the test kit provided.
Please note pH must be adjusted to correct levels to ensure an accurate reading see 8.3 pH.
Visit www.naked-pools.com or call 1800 NAKED1 (625 331) for further information.
Do not use Stabilizer (Cyanuric Acid)
Do not use Bromine compounds
Do not use Aluminium based or any other occulants
Do not use Soda Ash (Sodium Carbonate)
Do not use Granular Chlorine
Do not use forms of Zeolite ltration media
• Maintain your TDS (Total Dissolved Solids) level between 800-1000ppm for optimum performance and
complete Fresh Water experience.
• Decrease running times when temperature goes down - see 6.7 WINTER MODE.
Thank you again for choosing a NKD1 Fresh Water System.
We wish you many happy years of swimming in your Fresh Water Pool.
www.naked-pools.com 5

2. GENERAL OVERVIEW
2.2 Contents
2.3 Tools Needed
DRILL WITH 6MM
BASIC PVC FITTINGS
HACKSAW NO.2 PHILIPS HEAD SCREWDRIVER
PVC PRIMER
AND GLUE
AB
2X Green Wall
Plugs with Screws The Installation
& Operating Manual
2X50/40
Redusing Bushes
CONTROL UNIT OXIDISER, IONISER,
HOUSING WITH UNIONS WALL MOUNTING
BRACKET WATER TESTING
CARD
COPPER TEST KIT
www.naked-pools.com
6

3. POOL PREPARATION
Before operating your NKD1 Fresh Water System please read the following:
Handy Tips
• Check your TDS levels in your pool before starting your system.
• TDS levels should ideally be 800-1000ppm and no more than 1200ppm.
• For all new pool installations please seek advice from your pool builder before adding salt or
minerals as some new surfaces request no addition when initially completed.
• NEVER ADD SALT/MINERALS DIRECTLY TO THE SKIMMER BOX. This high concentration of
either salt or minerals will pass through your ltration, pump and other pool equipment and may
cause damage.
• The system can operate on mineral/magnesium chloride salts and you should allow an extra 20-30%
for these type of salts.
• Salt or minerals should always be added to the shallow end of the pool and allowed to dissolve. Do
not let the salt settle on the oor of the pool as this may cause damage to the surface. Use your
pool brush to mix the salt into the water.
• Running the pump will mix the water and help the salt/minerals to dissolve.
When taking your pool water to a pool shop for testing please ensure you take the
enclosed laminated NKD1 System Card to ensure your water is tested correctly and
accurate results are achieved. See handy tips 8.0 WATER CHEMISTRY.
• The only pool chemicals needed are those for normal water balance.
• Copper levels of 0.2-0.4ppm need to be achieved in order to optimally sanitise the pool water. On
initial start up the system allows for the literage of your pool to be entered and this is critical to
ensure the run times of the system and all the levels are set correctly.
If unsure visit www.naked-pools.com or call 1800 NAKED1 (625 331) for further information.
www.naked-pools.com 7

4. NKD1 SYSTEM INSTALLATION
4.2 Control Unit Installation
• The NKD1 Control Unit has an Ingress Protection Rating of IP23 enabling it to be installed outdoors.
Regulations require that the Control Unit shall be installed outside the pool zone. The Control Unit
shall be installed according to AS/NZS 3000 wiring rules.
• The Control Unit should be installed in a well ventilated position ideally away from sunlight and
rain to prolong life and at least 1m above ground to prevent run off water entry.
• Ensure that the Control Unit is not stored near chemicals, fertilisers or in a closed unventilated
shed with similar products as the fumes will cause excessive corrosion and damage to the internals
of the Control Unit and may void warranty.
• When mounting the Control Unit on a post it is recommended to install a at panel at least the
same size to act as a waterproof backing plate.
• Mount the Control Unit with the Wall Mounting Bracket, Green Plugs and Screws provided.
The Control Unit should be mounted no further than 1.5 metres from the Housing for ease of
operation.
4.1 Installation Diagram
OXI & ION CELL
FILTER
PUMP
POWER
CONTROL UNIT
(Ensure good venlaon)
RETURN
TO POOL
FROM
SKIMMER BOX
WARNING: DO NOT plug in if carton has been wet.
www.naked-pools.com
8

4. NKD1 SYSTEM INSTALLATION
4.4 ION Installation
• Check that the O-ring is clean, greased with silicone grease (DO NOT use petroleum based jelly) and
securely located in the Housing.
• Fit the ION Rods and ensure the Locking Ring is rmly tightened by hand (DO NOT use a tool to
tighten).
• Connect the plug to the base of the Control Unit ensuring a rm snap lock connection.
• Plug the Control Unit 3 pin plug into a suitable weatherproof RCD protected 10amp outlet and
then plug the pump into the 3 pin AC Socket located at the bottom of the Control Unit.
NOTE: The pump rating must not exceed 8amps.
WARNING:
• We DO NOT recommend the use of valves on the inlet or outlet of the Housing. If you do use a
valve then it is important to ensure that the valve cannot deadhead (lock closed) while the pump is
running. It is the installers responsibility to ensure some form of ow control is installed in this
instance and it disables the pump.
• ALWAYS ensure that pipe work and equipment do not allow gases generated to collect and build
up in any part of the installation.
• It is RECOMMENDED that the Housing be installed horizontally to create a natural gas trap that
acts as a safety device. Installation in any other way may cause explosion, injury or death if the
installer does not allow for gas removal. A venturi pipe is installed/moulded within the Housing
design to eliminate any possible gas build up, although it is always recommended to ensure
proper installation to eliminate this from happening.
• The Housing must be installed in the RETURN pipework to the pool. It must always be installed
after the lter, gas heater, solar heating or heat pump.
• DO NOT apply priming uid to the Housing, it is not needed and may react with the plastic.
4.3 OXI/Housing Installation
• Connect the Housing horizontally in the return line to the pool (use reducing bushes supplied if
40mm PVC pipe) using high pressure PVC glue. The Housing can be mounted vertically but
provision must be made for a gas trap.
• Direction of water ow through the Housing is not critical although we do recommend entry from
the OXI Cell end and exit from the ION Rod end of the Housing.
• Check that the O-ring is clean, greased with silicone grease (DO NOT use petroleum based jelly)
and securely located in the Housing.
• Fit the OXI Cell and ensure the Locking Ring is rmly tightened by hand (DO NOT use a tool to
tighten).
• Connect the plug to the base of the Control Unit ensuring a rm snap lock connection.
www.naked-pools.com 9

5. STARTING YOUR NKD1 FRESH WATER SYSTEM
www.naked-pools.com
10
5.2 Start Up Clock Set
START UP CLOCK SET allows you to program the exact time of the day.
HH digits will ash and pressing [+] will increase the time and pressing
[-] will decrease the time.
Pressing [OK] saves the selected hour HH and MM.
Pressing [<] skips this menu however you will need to set this later.
MM digits will ash and pressing [+] will increase the time and pressing
[-] will decrease the time.
Pressing [OK] saves the selected hour HH and MM.
Pressing [<] returns you to the previous screen.
5.1 Switching on the Unit
When switching on the NKD1 Fresh Water System for the rst time the screen to the
right will be displayed.
5.3 Mineral or Salt Mix
MINERAL OR SALT MIX allows you to enter the type of mineral used in the pool.
Pressing [+] or [-] will change it from SALT to MINERAL MIX.
The reason for this is because a higher salt reading (TDS value) is required for
MINERALS to be as conductive as SALT.
Pressing [OK] conrms your selection.
Pressing [<] returns you to the previous menu screen.
5.4 Initial Start Up
On intial start up the unit will ask whether or not there is copper is currently in the pool.
The reason for this is the copper level needs to be added into the water in order for
system to operate correctly and sanitise the water.
All new pool installations press [-]NO and continue to 5.5 START UP INFORMATION
Pressing [<] returns you to the previous menu screen.
If the pool contains copper and an ioniser system is currently being used press [+] and
follow the prompts. Start Up Information (5.5) will appear the unit will automatically set
the timers to run as per the volume of water entered and www.naked-pools.com or call
1800 NAKED1 (625 331) for further information.

5. INITIAL START UP OF YOUR NKD1 FRESH WATER SYSTEM
www.naked-pools.com 11
5.5 Start Up Information
START UP INFORMATION allows you to customise the unit to your pool size.
Pressing [+] or [-] will change it in 1,000lt increments.
Holding the [+] or [-] in will change it in 5,000lt increments.
A reading of 40,000Lt or similar ashes to show it can be changed.
Pressing [OK] conrms your selection. If you do not know your pool size you can press
[OK] and set this later or visit www.naked-pools.com or call 1800 NAKED1 (625 331) for
further information.
Pressing [<] returns you to the previous menu screen.
Selecting NO to DOES YOUR POOL CURRENTLY CONTAIN COPPER displays the
2 screens to the right.
The time displayed is the amount of hours the unit will run continuously to ensure the
copper levels are correct in the water based on the pool size entered in the previous
screen.
5.6 Default Display Screen
DEFAULT DISPLAY SCREEN (DDS) displays the screen to the right. This is the actual
output % of the unit.
Pressing [+] or [-] will increase the OXI Seng and the screen will change as seen on the
right.
This should always remain at 100% unless SPA MODE has been selected.
The (●) symbol indicates normal opearon.
T2 is the default mer displaying "Dual Timer Cycle" and T1 displays "Single Timer Cycle"
when single mer is selected.
The Mode shows AUTO and this can be changed by pressing Power/Mode (either AUTO,
ON or OFF).
The me shows with HH:MM in 24hr clock format.
The cell status shows as FWD when the cell is in the forward direcon and REV when in the
reverse direcon.
The pump AC socket status is displayed, either ON or OFF.
The ION Seng diplayed.
Any power failures return you to the DDS screen and the last saved MODE is acve.
Other manuals for NKD1
1
Table of contents
Other Naked Water System manuals
Popular Water System manuals by other brands

Grundfos
Grundfos Auto ADAPT ALPHA2 Installation and operating instructions

EcoWater
EcoWater EcoWater CWF Installation and operating manual

Professional Water Systems
Professional Water Systems 268 Homeowner's manual

Wayne
Wayne Jet Pump Water Systems Shallow Well Operating instructions and parts manual

Viega
Viega PureFlow installation manual

Kingspan
Kingspan BioDisc BAx Installation guidelines