2.4 RATING PLATE INFORMATION
Rating plate is located above and below the domestic hot water inlet and outlet.
W385-0413 / 07.16.10
LISTED SOLID FUEL FIRED CENTRAL FURNACE
TESTED TO:
CAN-CSA B366-1-M91 / UL391 4th Ed 2006 (JULY 2008) / UL 727 / CSAB140.4 / CSA B212
MODEL: HMF150 REPORT NO.: _415-S-09-2
CAUTION:
HOTWHILE INOPERATION.DO NOTTOUCH.KEEP CHILDREN,CLOTHINGAND
FURNITUREAWAY. CONTACTMAYCAUSE SKINBURNS.SEE NAMEPLATEAND
INSTRUCTIONS.
TECHNICAL DATA
BLOWER MOTOR 1/3 HP
ELECTRICAL RATING 120V, 11 AMPS, 60Hz
ELECTRIC FURNACE MODULE 220V,84 AMPS
EXTERNAL STATIC PRESSURE 0.2”W.C., 0.2”C.E.
DRAFT PRESSURE
WOOD FLUE: MIN. 0.04“ W.C.TO MAX.0.06” W.C.
OIL FLUE: MIN. 0.02”W.C.TO MAX. 0.04” W.C.
OIL FURNACE MAX. FIRING RATE 91,000 BTU INPUT
AS SHIPPED: - OIL PRESSURE: 120 PSI
- NOZZLE: 0.65 - 60°A
- NO.2 FURNACE OIL
INSTALLATION USE ONLY INACCORDANCE WITH WOLF STEEL LTD’S INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS OR OTHER AUTHORITIES HAVING
JURISDICTIONABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOURAREA.
CAUTION: THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. USE OF UNAUTHORIZED COMPONENTS OR FAILURE TO COMPLY WITH INSTALLA-
TION INSTRUCTIONS WILL RESULT IN VOIDED WARRANTY.
CHIMNEY TYPE: FOR “WOOD ONLY” FURNACE CONFIGURATION MINIMUM 6” (152mm) DIAMETER LISTED (UL103HT) RESIDENTIAL CHIMNEY. FOR “WOOD/OIL
COMBINATION” FURNACE RECOMMENDED MINIMUM 7”(178mm) DIAMETER LISTED (UL 103HT) RESIDENTIAL CHIMNEY.
CHIMNEY CONNECTOR: 6” (152mm) DIAMETER MINIMUM 24 GAUGE STEEL MINIMUM CLEARANCE FROM HORIZONTALCONNECTOR AND CEILING 18” (455mm).
SPECIAL METHODSARE REQUIRED WHENPASSING ACHIMNEY THROUGHA WALL OR CEILING. SEE INSTRUCTIONSAND BUILDING CODES.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVINGANOTHER APPLIANCE. EXCEPTION “ADD ON” CONFIGURATION WITHAN OIL FURNACE REFER TO MANUAL.
DO NOT CONNECT THIS FURNACE TO A CHIMNEY SERVICE A GAS APPLIANCE.
FUEL: FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH.
LOAD FUEL CAREFULLY OR DAMAGE MAY
RESULT.
OIL FURNACE MODULE NO.2 FURNACE OIL
DANGER: RISK OF FIRE OR EXPLOSION.
DO NOT ATTEMPT TO LIGHT AFIRE IF THERE IS AN OIL VAPOUR PRESENT.
DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.
DO NOT BURN GARBAGE, GASOLINE, NAPHTA, ENGINE OIL OR OTHER INAPPROPRIATE MATERIALS.
DO NOT STORE FUEL OR COMBUSTIBLE MATERIAL WITHIN INSTALLATION CLEARANCES OF THEAPPLIANCE.
DO NOT USE THIS FURNACE WITHOUT DUCTS – SEE MANUALFOR ALLOWABLE CONFIGURATION.
WARNING:
RISK OF SMOKE SPILLAGE. OPERATE ONLY WITH FIRINGAND ASHPIT DOOR TIGHTLY CLOSED. DO NOT OVERFIRE.
IF HEATER OR CHIMNEY CONNECTORS GLOW, YOU ARE OVERFIRING – IMMEDIATELY TURN OFF THERMOSTAT AND
ENSURE PRIMARY SHUTTER FIRING AND ASHPIT DOOR ARE CLOSED.
CAUTION: MAINTAIN COMBUSTIONAIR SUPPLY TO BOTH FURNACES. AIR STARVATION IS DANGEROUS (SEE MANUALUNDER “OUTSIDE COMBUSTION AIR”.
THE HMF150 FURNACE MAY BE CONNECTED TO DUCTWORK (SUPPLY SIDE – SEE MANUAL) OF ANOTHER FURNACE WHEN USEDAS AN WOOD FURNACE “ADD-ON”.
CERTIFIED FOR SERIES CONNECTION TO THE SUPPLY PLENUM OUTLET ONLY OF AGAS FIRED, OIL FIRED, OR ELECTRIC FURNACE.
DO NOT CONNECT DUCTWORK SO THAT REVERSE FLOW IS POSSIBLE.
FOR “ADD ON” INSTALLATION REFER TO MANUFACTURES INSTRUCTIONS FROM ORIGINAL FURNACE FOR INFORMAITON ON MINIMUM DUCT SIZING, ALLOWABLE
DUCT OPENINGS IN FURNACE CASINGAND ELECTRIC DIAGRAMS AND INFORMATION.
DO NOT RELOCATE OR BYPASS ANY OF THE SAFETY CONTROLS IN THE ORIGINAL FURNACE INSTALLATION (“ADD ON” CONFIGURATION).
DO NOT OBSTRUCT SPACE UNDER FURNACE. UNIT CAN BE INSTALLED ON COMBUSTIBLE SURFACE (WOOD SUBSTRATE ONLY – CARPETAND OTHER FLOOR
COVERINGS TO BE REMOVED) PROVIDING EMBER STOP SHIELD (SEE MANUAL) INSTALLED BETWEEN FURNACE AND FLOORAND MINIMUM 1 ¼” AIR GAP
MAINTAINED BETWEEN FURNACE AND FLOOR.
INCASE OF POWER FAILURE: PUSH DOWN ON THE CONTROL ARM OF THE PRIMARYAIR CONTROL AND LOCK IT DOWN USING ROTATING CLASP. TO AVOID
EXCESSIVE HEAT BEING TRAPPED IN DUCT WORK ENSUREALL RETURN AND SUPPLYAIR REGISTERS ARE NOT BLOCKED BY OBJECTS OR DEBRISAND ALL DUCT
CONTROL DAMPERS ARE SET OPEN. SEE MANUAL FOR OPERATION OF WOOD FURNACE IF ELECTRICAL POWER HAS BEEN INTERRUPTED.
OPERATE ORIGINAL FURNACE (ELECTRIC, OIL, GAS) OF A“ADD ON” CONFIGURATION PERIODICALLY TO ENSURE ITWILL OPERATE SATISFACTORILY WHEN NEEDED.
THE HEAT EXCHANGER, FLUE PIPE AND CHIMNEY MUSTBE INSPECTED FREQUENTLYAND CLEANED REGULARLYTO REMOVE ACCUMULATED CREOSOTE AND
ASH. UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. ENSURE THAT THE HEAT EXCHANGER, FLUE PIPE AND CHIMNEY ARE
CLEANED AT END OF BURNING SEASON, THIS HELPS TO MINIMIZE CORROSION IN THE SUMMER MONTHS. THEAPPLIANCE, FLUE PIPE AND CHIMNEY MUST BE
MAINTAINED IN GOOD CONDITION. UNSAFE TO FIRE WITH WOOD ABOVETOP OF REFRACTORY BRICK INSIDE COMBUSTIBLE CHAMBER.
USE SUPPLY WIRES SUITABLE FOR 90°C. SEE INSTRUCTION MANUAL FOR ELECTRICALDIAGRAM.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. FOR MORE INFORMATION REFER TO OWNER’S MANUAL.
CAUTION: TWO SOURCES OF ELECTRICAL ENERGY PRESENT IN ELECTRIC FURNACE MODULE - DISCONNECT 220V SUPPLY TO MODULEAND 120V SUPPLYTO
HMF150 FURNACE BEFORE SERVICING.
REPLACE ALL CRACKED OR BROKEN FIRE BRICK AND TOP BAFFLES. REPLACE GLASS ONLY WITH CERAMIC GLASS.
AUTHORIZED MODULES FOR CONNECTION TO HMF150 FURNACE: BLOWER BOX MODULE - HMFK-BMP33, ELECTRIC FURNACE MODULE-HMFK-EF20, OIL FURNACE
MODULES - HMFK-OFRF40, HMFK-OFAFG, DHW PREHEAT MODULE - HMFK-DHW, “ADD ON” KIT - HMFK-ADDON
THESE ARE THE ONLYAUTHORIZED COMPONENTS THAT MAY BE ATTACHED TO THE HMF150 FURNACEASIDE FROM CONNECTION TO FORCED AIR SYSTEM
RETURN AND SUPPLY PLENUMS. MODULES MUST BE INSTALLED TO MANUFACTURERS INSTRUCTIONS POSTED IN THE INSTALLATION/OWNERS MANUALACCOMPA-
NYING HMF150 AND INSTRUCTION ADDENDUMS INCLUDED WITH EACH MODULE.
HMF150 CONFIGURED AS AN “ADD ON”:
MAY BE ADDED ONTOA FURNACE HAVING ARATING AS SHOWN ON THE ORIGINAL NAME PLATE BETWEEN:
.:0,1,080$1'.:0$;,080)25(/(&75,&)851$&(
0,1,080$1'0$;,08086*3+)252,/)851$&(,1387
0$;,080%78+)25*$6)851$&(,1387
REFER TO OWNERS MANUAL
WOLFSTEEL LTD. 24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y8 CANADA
18”
MAX 16”
CLEARANCE TO COMBUSIBLES
SERVICE CLEARANCE
24”
14”
CLEARANCE TO COMBUSIBLES
SERVICE CLEARANCE
24”
LEFT HAND RA CONFIGURATION (REAR VIEW)
MINIMUM 40”
18”
14”
MINIMUM 52”
9”
*Drawing not to scale
OIL FURNACE FLUE
WOOD, WOOD/OIL FLUE
NOTE5()(5720$18$/)255,*+7+$1'&21),*85$7,21&/($5$1&(72&20%867,%/(6
7+((/(&75,&)851$&(02'8/(1276+2:1)$//6:,7+,1(19(/23(2)&/($5$1&(72&20%867,%/(6)25:22':22'2,/&21),*85$7,217+(&/($5$1&((19(/23(6'2127
CHANGE WITH ADDITION OF THE ELECTRIC FURNACE.
CLEARANCE TO COMBUSTIBLES
CLEARANCE TO COMBUSTIBLES
48”
18”
24”
1.25”
CLEARANCE TO COMBUSTIBLES
SERVICE CLEARANCE
LEFT HAND RA CONFIGURATION (SIDE VIEW BLOWER MODULE)
9”
*Drawing not to scale
OIL FURNACE FLUE
WOOD, WOOD/OIL FLUE
NOTE:
SECTION “C” CLEARANCES MAY BE REDUCED TO 0.375”BEYOND A BEND OR
OFFSET IN THE DUCT SUFFICIENTLY LARGE TO SHIELD THE REMAINDER OF
THE SUPPLY DUCT FROM DIRECT RADIATION FROM THE FURNACE HEAT
EXCHANGER.
72”
1”
6”
7 ft. MINIMUM CEILING HEIGHT
40”
>72”
A
B
C
NOTE:
See
CAN/CSA-
B365.01 and
NFPA211 for
clearance to
combustible
specications
for return air
ducting.
CLEARANCE TO COMBUSTIBLES
*Drawing not to scale.
CLEARANCE TO COMBUSTIBLES SECTION
ABC
TOP 6” 6” 1”
BOTTOM/SIDES 18” 6” 1”
SERIAL
NO. HMF150
MANUFACTURE DATE:
JAN APR JUL OCT
FEB MAY AUG NOV
MAR JUN SEP DEC
2010 2011 2012 2013
W385-0413
HMF150
LISTEDSOLIDFUELFIRED CENTRAL FURNACE
TESTEDTO:
CAN-CSAB366-1-M91/UL3914th Ed2006(JULY 2008)/UL727/CSAB 140.4/ CSAB 212
MODEL:HMF150
REPORTNO.:_
415-S-09-2_
CAUTION:
HOTWHILEINOPERATION.DONOTTOUCH.KEEPCHILDREN,CLOTHINGANDFURNITUREAWAY.
CONTACTMAYCAUSESKINBURNS.SEENAMEPLATEANDINSTRUCTIONS.
TECHNICAL DATA
BLOWER/VENTILATEUR 1/3HP
ELECTRICALRATING/ 120V,10.3 AMPS,
ALIMENTATIONELECTRIQUE 60Hz
EXTERNALSTATICPRESSURE/ 0.2”W.C.
PRESSIONSTATIQUEEXT.0.2”C.E.
DRAFTPRESSURE/
WOODFLUE: MIN.0.4”W.C
OILFLUE: 0.2”W.C.
OILFURNACE-OILFIRINGRATE:0.66GALUS
-OILPRESSURE: 120PSI
-NOZZLE: 0.65-60°A
INSTALLATION-USEONLYINACCORDANCEWITHWOLFSTEELLTD’SINSTRUCTIONS.CONTACTLOCALBUILDING,FIRE OFFICIALS AND OTHERAGENCIES HAVINGLOCA
JURISDICTIONABOUTRESTRICTIONSANDINSTALLATIONINSPECTIONINYOURAREA.
CHIMNEYTYPE:FOR“WOODONLY” FURNACE CONFIGURATION MINIMUM 6”(152mm) DIAMETER LISTED (UL103HT) RESIDENTIALCHIMNEY.FOR“WOOD/OIL
COMBINATION”FURNACERECOMMENDEDMINIMUM7”(178mm)DIAMETERLISTED (UL 103HT) RESIDENTIAL CHIMNEY.
DONOTCONNECTTHISUNITTO ACHIMNEY FLUESERVING ANOTHER APPLIANCEUNLESS USING IN A “ADD ON” CONFIGURATION WITH A PRE EXISITNG OIL
FURNACE-SEEMANUALUNDERPLENUM AND INSTALLATION.
CHIMNEYCONNECTOR:6”(152mm)DIAMETERMINIMUM24 GAUGE STEELMINIMUM CLEARANCE FROMHORIZONTALCONNECTORAND CEILING 18” (455mm).
SPECIALMETHODSAREREQUIRED WHEN PASSINGACHIMNEYTHROUGHA WALLOR CEILING.SEEINSTRUCTIONSANDBUILDINGCODES.
DONOTOBSTRUCTSPACEUNDERFURNACE.UNIT CANBEINSTALLEDON COMBUSTIBLESURFACE(WOOD SUBSTRATEONLY – CARPET ANDOTHER FLOOR
COVERINGSTOBEREMOVED)PROVIDINGEMBERSTOPSHIELD (SEE MANUAL)INSTALLED BETWEENFURNACEANDFLOORAND MINIMUM 1 ¼” AIR GAP
MAINTAINEDBETWEENFURNACEANDFLOOR.
FUEL:FORUSEWITHSOLIDWOODFUEL ONLY.DONOT USE GRATE OR ELEVATEFIRE.BUILD WOOD FIREDIRECTLYONHEARTH.
AUTHORIZEDMODULESFORCONNECTIONTOHMF150FURNACE:
BLOWERBOXMODULE- HMFK-BMP33
ELECTRICFURNACEMODULE-HMFK-EF20
OILFURNACEMODULES- HMFK-OFRF40,HMFK-OFAFG
DHWPREHEATMODULE-HMFK-DHW
“ADDON”FURNACEMODULE-HMFK-ADDON
THESEARETHEONLYAUTHORIZED COMPONENTS THAT MAYBEATTACHEDTO THEHMF150FURNACE ASIDEFROMCONNECTION TO FORCEDAIR SYSTEM
RETURNANDSUPPLYPLENUMS.MODULESMUSTBEINSTALLEDTOMANUFACTURERSINSTRUCTIONSPOSTED IN THE INSTALLAT ION/OWNERSMANUAL
ACCOMPANYINGHMF150ANDINSTRUCTIONADDENDUMSINCLUDEDWITH EACH MODULE.
THEHMF150FURNACEISCERTIFIED FORSERIESCONNECTIONTO THESUPPLY PLENUM OUTLETONLY OFAGAS FIRED,OILFIRED,ORELECTRICFURNACEWHEN
USEDASANWOODFURNACE“ADD-ON”.
DONOTCONNECTTHISFURNACE TO A CHIMNEY SERVICEAGAS FURNACE.
DONOTCONNECTDUCTWORKSOTHATREVERSEFLOW IS POSSIBLE.
DONOTRELOCATEORBYPASSANYOF THE SAFETYCONTROLS IN THE ORIGINALFURNACE INSTALLATION (”ADDON” CONFIGURATION).
CAUTION:THISAPPLIANCEMUST BEINSTALLEDBY AQUALIFIEDINSTALLER.USE OFUNAUTHORIZEDCOMPONENTSOR FAILURETOCOMPLYWITH
INSTALLATIONINSTRUCTIONSWILLRESULTIN VOIDED WARRANTY.
WARNING:RISKOFSMOKESPILLAGE.OPERATEONLYWITHFIRINGANDASHREMOVAL DOOR TIGHTLY CLOSED.DO NOT OVERFIRE.
IFHEATERORCHIMNEYCONNECTORS GLOW, YOUAREOVERFIRING –IMMEDIATELYTURN OFF THERMOSTAT ANDENSUREPRIMARY SHUTTER FIRINGAND ASH
REMOVALDOORARECLOSED.
SEEMANUALFOROPERATIONOFWOODFURNACE IF ELECTRICALPOWERHAS BEEN INTERRUPTED.
THEHEATEXCHANGER,FLUEPIPEANDCHIMNEYMUSTBEINSPECTEDFREQUENTLYANDCLEANED REGULARLY TO REMOVEACCUMULATEDCREOSOTEAND
ASH.UNDERCERTAINCONDITIONS OF USE, CREOSOTEBUILDUP MAY OCCURRAPIDLY.ENSURETHATTHEHEAT EXCHANGER,FLUEPIPEANDCHIMNEYARE
CLEANEDATENDOF BURNING SEASON, THISHELPSTO MINIMIZE CORROSIONINTHE SUMMER MONTHS.THEAPPLIANCE,FLUE PIPE ANDCHIMNEY MUST BE
MAINTAINEDINGOODCONDITION.UNSAFETO FIREWITH WOODABOVE TOPOF REFRACTORY BRICK INSIDE COMBUSTIBLE CHAMBER.
REPLACEALLCRACKEDORBROKENFIRE BRICK AND TOP BAFFLES.
LOADFUELCAREFULLYORDAMAGEMAYRESULT.
DONOTATTEMPTTOLIGHTA FIRE IF THERE IS AN OIL VAPOURPRESENT.
DONOTUSECHEMICALSORFLUIDSTOSTARTTHEFIRE.
DONOTBURNGARBAGE,GASOLINE,NAPHTA,ENGINE OIL OR OTHER INAPPROPRIATE MATERIALS.
DONOTSTOREFUELORCOMBUSTIBLEMATERIALWITHININSTA LLATIONCLEARANCESOFTHEAPPLIANCE.
DONOTUSETHISFURNACEWITHOUT DUCTS – SEE MANUALFOR ALLOWA BLECONFIGURATION.
CAUTION:USESUPPLYWIRES SUITABLEFOR167°F/75°C.SEEINSTRUCTIONMANUAL FOR ELECTRICALDIAGRAM.
CAUTION:REPLACEGLASSONLYWITHCERAMICGLASS.
DANGER:RISKOFELECTRICALSHOCK.DISCONNECTPOWERBEFORESERVICING UNIT- DISCONNECT POWERFROM BOTH FURNACESINA“ADD ON”
CONFIGURATION.
MAYBEADDEDONTOAFURNACEHAVINGARATINGASSHOWNONTHEORIGINALNAMEPLATE BETWEEN:
15KWMINIMUMAND20KW MAXIMUMFOR ELECTRICFURNACE
0.4MINIMUMAND0.65MAXIMUMUSGPHFOROILFURNACE
60,000MINIMUMAND80,000MAXIMUMBTU/HFORGASFURNACE
CAUTION:MAINTAINCOMBUSTIONAIRSUPPLYTO BOTHFURNACES.AIR STARVATIONIS DANGEROUS (SEEMANUAL UNDER “OUTSIDECOMBUSTIONAIR”).
FOR“ADDON”INSTALLATIONREFER TO MANUFACTURES INSTRUCTIONSFROMORIGINAL FURNACEFORINFORMATIONON MINIMUM DUCT SIZING,ALLOWABLE
DUCTOPENINGSINFURNACECASINGAND ELECTRICDIAGRAMS ANDINFORMATION.
OPERATEORIGINALFURNACE(ELECTRIC,OIL,GAS)OF A “ADD ON”CONFIGURATION PERIODICALLY TO ENSURE ITWILLOPERATESATISFACTORILYWHENNEEDED.
6ft
6”1”
1.25”
MODELNO.SERIALNO.
MADEINCANADA WITH DOMESTICANDIMPORTEDP
ARTSBY:
WOLFSTEELLTD.
24NAPOLEONROAD,BARRIE, ON, L4M 4Y8CANADA
26”
17”
14”AND“S”
1.25”
48”
“S”
14”
NOTE:
“S”=MINIMUM24”SERVICECLEARANCEREQUIRED
REFERTOSECTION6.0OFTHEINSTALLATIONANDOPERATINGINSTRUCTIONMANUAL.
W385-0413
HMF150
LISTEDSOLIDFUELFIREDCENTRAL FURNACE
TESTEDTO:
CAN-CSAB366-1-M91/UL3914thEd2006( JULY2008)/UL727/CSAB 140.4 / CSA B212
MODEL:HMF150
REPORTNO.:_
415-S-09-2_
CAUTION:
HOTWHILEINOPERATION.DONOTTOUCH.KEEPCHILDREN,CLOTHINGANDFURNITUREAWAY.
CONTACTMAYCAUSESKINBURNS.SEENAMEPLATEANDINSTRUCTIONS.
TECHNICAL DATA
BLOWER/VENTILATEUR1/3HP
ELECTRICALRATING/ 120V,10.3AMPS,
ALIMENTATIONELECTRIQUE 60Hz
EXTERNALSTATICPRESSURE/ 0.2”W.C.
PRESSIONSTATIQUEEXT.0.2”C.E.
DRAFTPRESSURE/
WOODFLUE: MIN.0.4”W.C
OILFLUE: 0.2”W.C.
OILFURNACE-OILFIRINGRATE: 0.66GAL US
-OILPRESSURE: 120PSI
-NOZZLE: 0.65-60°A
INSTALLATION-USEONLY INACCORDANCE WITHWOLFSTEELLTD’S INSTRUCTIONS. CONTACT LOCAL BUILDING,FIRE OFFICIALS AND OTHER AGENCIES HAVINGLOCA
JURISDICTIONABOUTRESTRICTIONSANDINSTALLATIONINSPECTIONINYOURAREA.
CHIMNEYTYPE:FOR“WOODONLY”FURNACECONFIGURATION MINIMUM6”(152mm) DIAMETERLISTED (UL103HT)RESIDENTIALCHIMNEY. FOR “WOOD/OIL
COMBINATION”FURNACERECOMMENDEDMINIMUM7”(178mm)DIAMETERLISTED(UL103HT)RESIDENTIAL CHIMNEY.
DONOTCONNECTTHIS UNIT TO ACHIMNEYFLUESERVING ANOTHER APPLIANCEUNLESS USING IN A “ADDON” CONFIGURATION WITH A PREEXISITNG OIL
FURNACE-SEEMANUALUNDERPLENUMAND INSTALLATION.
CHIMNEYCONNECTOR:6”(152mm)DIAMETERMINIMUM 24 GAUGE STEELMINIMUM CLEARANCEFROM HORIZONTAL CON NECTORAND CEILING 18” (455mm).
SPECIALMETHODSAREREQUIREDWHEN PASSINGACHIMNEYTHROUGHAWA LL OR CEILING.SEEINSTRUCTIONSANDBUILDING CODES.
DONOTOBSTRUCTSPACEUNDERFURNACE.UNITCANBEINSTALLEDONCOMBUSTIBLESURFACE(WOOD SUBSTRATE ONLY – CARPETAND OTHERFLOOR
COVERINGSTOBEREMOVED)PROVIDINGEMBERSTOPSHIELD(SEE MANUAL) INSTALLED BETWEEN FURNACE ANDFLOORANDMINIMUM1 ¼” AIR GAP
MAINTAINEDBETWEENFURNACEANDFLOOR.
FUEL:FORUSEWITHSOLIDWOODFUELONLY.DO NOTUSE GRATEORELEVATEFIRE.BUILDWOODFIRE DIRECTLYON HEARTH.
AUTHORIZEDMODULESFORCONNECTIONTOHMF150FURNACE:
BLOWERBOXMODULE-HMFK-BMP33
ELECTRICFURNACEMODULE-HMFK-EF20
OILFURNACEMODULES- HMFK-OFRF40, HMFK-OFAFG
DHWPREHEATMODULE-HMFK-DHW
“ADDON”FURNACEMODULE-HMFK-ADDON
THESEARETHEONLYAUT HORIZEDCOMPONENTSTHATMAY BEATTACHED TO THEHMF150 FURNACE ASIDE FROM CONNECTION TO FORCEDAIR SYSTEM
RETURNANDSUPPLYPLENUMS.MODULESMUSTBEINSTALLEDTOMANUFACTURERSINSTRUCTIONSPOSTED IN THE INSTALLATION/OWNERSMANUAL
ACCOMPANYINGHMF150ANDINSTRUCTIONADDENDUMSINCLUDEDWITHEACHMODULE.
THEHMF150FURNACEISCERTIFIEDFORSERIES CONNECTION TOTHESUPPLYPLENUMOUTLETONLY OFAGAS FIRED,OILFIRED,OR ELECTRICFURNACEWHEN
USEDASANWOODFURNACE“ADD-ON”.
DONOTCONNECTTHISFURNACETOA CHIMNEY SERVICEA GAS FURNACE.
DONOTCONNECTDUCTWORKSO THAT REVERSE FLOWIS POSSIBLE.
DONOTRELOCATEORBYPASSANYOFTHESAFETYCONTROLSIN THE ORIGINAL FURNACE INSTALLATION (”ADD ON” CONFIGURATION).
CAUTION:THISAPPLIANCE MUSTBEINSTALLEDBY A QUA LIFIED INSTALLER.USE OF UNAUTHORIZEDCOMPONENTSOR FAIL URETOCOMPLYWITH
INSTALLATIONINSTRUCTIONSWILLRESULTINVOIDEDWARRANTY.
WARNING:RISKOFSMOKESPILLAGE.OPERATEONLYWITHFIRINGANDASHREMOVAL DOOR TIGHTLYCLOSED. DO NOTOVERFIRE.
IFHEATERORCHIMNEYCONNECTORSGLOW,YOUARE OVERFIRING–IMMEDIATELYTURN OFFTHERMOSTAT AND ENSURE PRIMARY SHUTTER FIRING ANDASH
REMOVALDOORARECLOSED.
SEEMANUALFOROPERATIONOF WOODFURNACEIF ELECTRICAL POWERHASBEEN INTERRUPTED.
THEHEATEXCHANGER,FLUEPIPEANDCHIMNEYMUST BE INSPECTED FREQUENTLYANDCLEANED REGULARLY TO REMOVE ACCUMULATED CREOSOTE AND
ASH.UNDERCERTAINCONDITIONS OFUSE, CREOSOTEBUILDUP MAY OCCURRAPIDLY. ENSURETHAT THEHEATEXCHANGER, FLUEPIPE ANDCHIMNEY ARE
CLEANEDATENDOFBURNINGSEASON,THISHELPSTO MINIMIZE CORROSION IN THE SUMMERMONTHS.THE APPLIANCE, FLUEPIPEA NDCHIMNEYMUSTBE
MAINTAINEDINGOODCONDITION.UNSAFE TO FIRE WITH WOOD ABOVE TOP OF REFRACTORY BRICK INSIDE COMBUSTIBLE CHAMBER.
REPLACEALLCRACKEDORBROKENFIREBRICKANDTOPBAFFLES.
LOADFUELCAREFULLYORDAMAGE MAY RESULT.
DONOTATTEMPTTOLIGHTA FIREIF THEREIS ANOIL VAPOUR PRESENT.
DONOTUSECHEMICALSORFLUIDS TOSTARTTHEFIRE.
DONOTBURNGARBAGE,GASOLINE,NAPHTA,ENGINE OILOR OTHER INAPPROPRIATEMATERIALS.
DONOTSTOREFUELORCOMBUSTIBLEMATERIAL WITHIN INSTALLATION CLEARANCES OF THE APPLIANCE.
DONOTUSETHISFURNACEWITHOUTDUCTS–SEEMANUAL F ORALLOWABLECONFIGURATION.
CAUTION:USESUPPLYWIRESSUITABLEFOR167°F/75°C.SEEINSTRUCTIONMANUALFORELECTRICALDIAGRAM.
CAUTION:REPLACEGLASS ONLY WITH CERAMIC GLASS.
DANGER:RISKOFELECTRICALSHOCK. DISCONNECT POWER BEFORE SERVICING UNIT - DISCONNECT POWERFROM BOTH FURNACESINA“ADD ON”
CONFIGURATION.
MAYBEADDEDONTO AFURNACE HAVINGAR ATINGASSHOWNON THEORIGINAL NAMEPLATEBETWEEN:
15KWMINIMUMAND20KWMAXIMUMFOR ELECTRICFURNACE
0.4MINIMUMAND0.65MAXIMUMUSGPHFOROIL FURNACE
60,000MINIMUMAND80,000MAXIMUMBTU/HFOR GASFURNACE
CAUTION:MAINTAINCOMBUSTIONAIRSUPPLYTO BOTH FURNACES. AIRSTARVATIONIS DANGEROUS (SEEMANUALUNDER “OUTSIDE COMBUSTION AIR”).
FOR“ADDON”INSTALLATIONREFERTO MANUFACTURESINSTRUCTIONSFROM ORIGINAL FURNACEFOR INFORMATIONONMINIMUMDUCT SIZING,ALLOWABLE
DUCTOPENINGSINFURNACECASINGAND ELECTRIC DIAGRAMSANDINFORMATION.
OPERATEORIGINALFURNACE(ELECTRIC,OIL,GAS)OFA “ADD ON”CONFIGURATIONPERIODICALLYTOENSUREITWILLOPERATE SATISFACTORILY WHENNEEDED.
6ft
6”1”
1.25”
MODELNO. SERIALNO.
MADEINCANADAWITHDOMESTICANDIMPORTED PARTS BY:
WOLFSTEELLTD.
24NAPOLEONROAD,BARRIE,ON, L4M 4Y8 CANADA
26”
17”
14”AND“S”
1.25”
48”
“S”
14”
NOTE:
“S”=MINIMUM24”SERVICECLEARANCEREQUIRED
REFERTOSECTION6.0OFTHEINSTALLATIONANDOPERATINGINSTRUCTIONMANUAL.